pH Control of Feed Water for HRSG with Additional Injection of NH3 (암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절)

  • Mok, Yong-kang;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.32-38
    • /
    • 2015
  • This study was conducted on combined cycle power plant consisting of HRSG with integral deaerator type to avoid tube failures of low pressure evaporator tubes. Based on the observation of pH variation at the discharge of boiler feed water pump by continuous pH measurement for a period of time, it was identified that pH of feed water is getting reduced as ammonia is distributed into vapor and liquid depending on the distribution ratio of ammonia in the LP drum after the deaerator. To solve this problem, the counterplan was prepared by reexamination of ammonia injection point and quantity. In conclusion, it was accomplished that 9.2~9.6 is the optimized pH range for boiler feed water by arranging additional piping for ammonia to inject directly to LP drum.

  • PDF

Effects of Disinfectants on Larval Development of Ascaris suum Eggs

  • Oh, Ki-Seok;Kim, Geon-Tae;Ahn, Kyu-Sung;Shin, Sung-Shik
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.1
    • /
    • pp.103-107
    • /
    • 2016
  • The objective of this study was to evaluate the effects of several different commercial disinfectants on the embryogenic development of Ascaris suum eggs. A 1-ml aliquot of each disinfectant was mixed with approximately 40,000 decorticated or intact A. suum eggs in sterile tubes. After each treatment time (at 0.5, 1, 5, 10, 30, and 60 min), disinfectants were washed away, and egg suspensions were incubated at $25^{\circ}C$ in distilled water for development of larvae inside. At 3 weeks of incubation after exposure, ethanol, methanol, and chlorohexidin treatments did not affect the larval development of A. suum eggs, regardless of their concentration and treatment time. Among disinfectants tested in this study, 3% cresol, 0.2% sodium hypochlorite and 0.02% sodium hypochlorite delayed but not inactivated the embryonation of decorticated eggs at 3 weeks of incubation, because at 6 weeks of incubation, undeveloped eggs completed embryonation regardless of exposure time, except for 10% povidone iodine. When the albumin layer of A. suum eggs remained intact, however, even the 10% povidone iodine solution took at least 5 min to reasonably inactivate most eggs, but never completely kill them with even 60 min of exposure. This study demonstrated that the treatment of A. suum eggs with many commercially available disinfectants does not affect the embryonation. Although some disinfectants may delay or stop the embryonation of A. suum eggs, they can hardly kill them completely.

Pure Isolation and Identification of Babesia ovata by Morphological Characteristics and Complement Fixation Test in Korea (Babesia ovata의 순수분리와 형태학적 및 혈청학적 동정)

  • Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.307-316
    • /
    • 1987
  • This study was conducted to identify Babesia sp. strain isolated from the imported beef cattle, Aberdeen-angus heifers, in J farm of Jangsu Prefecture, Cheon-buk Province of Korea, morphologically, etiologically and serologically. Babesia sp. strain was purely isolated through the serial blood passages of three generations against splenectomized calves and one generation of blood passage against non-splenectomized calf(intact calf) by inhibiting the appearance of Theileria sergenti in the blood stream by means of injection of 20% oil pamaquine intramuscularly. In the splenectomized calves, the parasite multiplied markedly in blood stream soon after inoculation and parasitaemia was much severe. An elevated body temperature, anorexia, severe anaemia and icterus were observed clinically. Of three splenectomized calves, two were affected with haemoglobinuria and died. But in the non-splenectomized calf the clinical signs and parasitaemia were very mild. The means of the incubation period, the highest parasitaemia, the highest body temperature and the lowest PCV were 3.5 days, 41.1%, ${42^{\circ}C}$ and 9%, respectively, in the splenectomized calves. In calf erythrocytes Babesia sp. protozoa were polymorphic showing the round, oval, ameboid, piriform and paired piriform etc. The sizes of protozoa were $2.51{\sim}3.91{\times}1.32{\sim}2.19{{\mu}m}$ ($3.20{\times}1.60{\mu}m$). Serologically the isolated Babesia sp. were compared with other parasites, B. ovata, B. bigemina, B. bovis, T. sergenti, A. marginale and A. centrale by using the complement fixation(CF) test. As a result, the antibody titer between the homologous species were high. It was two tubes or more in the CF test. From the results obtained above the pure isolated Babesia species was identical with Babesia ovata Minami and Ishihara, 1980.

  • PDF

Evaluation of P-M Interaction Curve for Circular Concrete-Filled Tube (CFT) Column (원형 콘크리트 충전 강관(CFT) 기둥의 P-M 상관 곡선 평가)

  • Moon, Jiho;Park, Keum-Sung;Lee, Hak-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.355-365
    • /
    • 2014
  • Concrete-filled tubes (CFTs) have been used in civil engineering practices as a column of buildings and a bridge pier. CFTs have several advantages over the conventional reinforced concrete columns, such as rapid construction, enhanced buckling resistance, and inherited confinement effect. However, CFT component have not been widely used in civil engineering practice, since the design provisions among codes significantly vary each other. It leads to conservative design of CFT component. In this study, the design provisions of AISC and EC4 for CFT component were examined, based on the extensive test results conducted by previous researchers and finite element analysis results obtained in this study. Especially, the focus was made on the validation of P-M interaction curves proposed by AISC and EC4. From the results, it was found that the current design codes considerably underestimated the strength of CFT component under general combined axial load and bending. Finally, the modified P-M interaction curve was proposed and successfully verified.

Design and Experimental Results for Cooling Tubes of Ultrasonic Bonding Equipment of Ultrasonic Bonding Equipment (초음파 접합 장치의 냉각관 설계 및 접합강도 실험)

  • Lee, DongWook;Jeon, EuySick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1879-1884
    • /
    • 2014
  • Recently, the micro bonding technology comes into the spotlight as the miniaturization of the electronic product. The micro bonding technique can classify by way of laser welding and ultrasonic bonding and etc. However, the research on the micro bonding is much lacks. In this paper, carried out the cooling analysis of the 60 [kHz] ultrasonic bonding equipment to know heat effect of the piezoelectric element when the ultrasonic bonding equipment was operated. The ultrasonic horn having the natural frequency with 60 [kHz] for the dissimilar material bonding of the glass and solder tried to be designed. The parameters and response was set through the basic experiment. The dissimilar material bonding strength analysis using the 60 [kHz] ultrasonic bonding equipment was done. We carried out the bonding for improving bonding strength to using the silver paste. air thightness of bonding surface was confirmed by analysis of bonding interfaces.

Experimental Approach for Estimation of Hydrodynamic Force Acting on a Submerged Streamlined Body Translating in a One-end-opened Cylindrical Tube (수중운동체의 실린더 관 내부 이동시 작용력 예측에 대한 실험적 접근)

  • Yeo, Dong-Jin;Kim, Yeon-Gyu;Kim, Dong-Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.2
    • /
    • pp.203-211
    • /
    • 2012
  • The main object of this experiment is to estimate the hydrodynamic forces acting on a submerged streamlined body placed in a one-end-opened cylindrical tube moving with certain translational velocity. The best experimental design for this object is mimicking real situation, however sizes of model body and cylinder tube are just the same as those of real, for avoiding scale effects, mimicking real situation is not realizable. Hence, in this experiment, target body and cylindrical tube were designed to be towed with varying body position relative to cylindrical tube. For measuring hydrodynamic forces and flow velocity in the cylindrical tube, six one-component load cells and several one-hole Pitot tubes were used. Several conditions were checked with various end-plates those had different opening areas. Experiment results show that forces and flow velocity had different tendency with those expected, and the presence of a end-plate slows down the flow velocity in the cylindrical tube and affects pressure field in the tube to push the model submerged body forward of the tube. This tendency grows with decreasing opened area.

Development and Characterization of Translucent Opal Glass for Diffuser of LED Lighting (LED 조명용 반투명 유백유리 Diffuser 조성 개발 및 특성)

  • Ku, Hyun-Woo;Lim, Tae-Young;Hwang, Jonghee;Kim, Jin-Ho;Lee, Mi-Jai;Shin, Dong Wook
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.650-657
    • /
    • 2012
  • For the purpose of improving the durability problem, translucent opal glass was fabricated as a substitute for the polycarbonate diffuser of LED lighting. Calcium phosphate was used as an opacifier of opal glass and melted in an electric furnace. The opaque effect was identified according to the change of the cooling procedure. As results, translucent opal glass was obtained by the melting of a batch with a composition of 3.8% calcium phosphate at $1550^{\circ}C$ for 2 hrs and then the cooling of the material in the furnace. For the cooling condition of the glass sample, HTCG (High Temperature Cooled Glass) was found to have better optical properties than LTAG (Low Temperature Annealed Glass). It had excellent optical properties for a diffuser of LED lighting, with no dazzling from direct light due to its high haze value of over 99% and low parallel transmittance value of under 1%. For the thermal properties, it had an expressed thermal expansion coefficient of $5.7{\times}10^{-6}/^{\circ}C$ and a softening point of $876^{\circ}C$; it also had good thermal properties such as good thermal shock resistance and was easy to apply to the general manufacturing process in the forming of glass tubes and bulbs. Therefore, it is concluded that this translucent opal glass can be used as a glass diffuser material for LED lighting with high heat resistance and high durability; this material is suitable as a substitute for polycarbonate diffusers.

Photocatalytic activity under visible-light with metal or $WO_3$ deposited-$TiO_2$ tubes (가시광감응을 위한 금속이나 $WO_3$ 도핑된 $TiO_2$ 튜브의 광활성 연구)

  • Heo, Ahyoung;Lee, Changha;Park, Minsung;Shim, Eunjung;Yoon, Jaekyung;Joo, Hyunku
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.227.1-227.1
    • /
    • 2010
  • 본 연구는 자외선 영역의 흡수로 전자 정공의 전하쌍을 생성함으로써 광전압 및 전류를 일으키는 티타니아 물질을 금속지지체 표면에 양극산화로 튜브형 $TiO_2$(anodized tubular $TiO_2$; ATT)로 제조한 후 나노크기의 금속 혹은 $WO_3$입자를 담지하여 광감응 재료로 활용하였다. 이는 기존의 입자나 콜로이드 형태로 광촉매 물질을 고정화하여 사용한 재료의 탈리현상 및 효율저하를 극복하기 위함이다. ATT는 전해질 내에 전기화학적 에칭율과 화학적 용해율의 비율에 의해 나노튜브 길이 성장에 영향을 미치는데 이를 유기 전해질과 불산 전해질을 사용하여 정전압 혹은 정전류의 조건에서 다양한 길이의 $TiO_2$ 나노튜브를 제조하였다. 여기에 전기분해담지(electrolytic deposition; ELD)를 통하여 정전류 조건에서 다양한 금속(Pt, Pd, Ru)을 나노크기의 형태로 담지하여 광촉매 내 생성된 전자 정공의 재결합을 줄이고자 하였고 $WO_3$의 담지를 통하여 가시광 감응을 높이고자 하였다. 제조된 여러 조건의 시료는 SEM과 EDAX를 통하여 형태와 길이, 담지량을 확인 하고 XRD를 이용하여 열처리 온도에 따른 결정화상태를 확인하였으며 광전류 측정 및 Cr(VI)의 광환원과 MB의 광분해를 통하여 광효율을 관찰하였다. 금속이 도핑되었을 경우 순수 ATT보다 보통 3배의 흡착률과 UV광원 아래 2배의 광효율을 관찰할 수 있었는데 이 중 Pt의 담지가 가장 효율이 좋았으며 흡착률에서는 담지량의 증가에 따른 증가선을 관찰 할 수 있었으나 광원 사용시 3%담지율에서 최적을 확인 할 수 있었다. 또한 $TiO_2$외 가시광감응 활성을 높이기 위한 다양한 광촉매제조가 진행 중에 있다.

  • PDF

A study on the evaluation for material degradation of 0.0Cr-0.5Mo steel by a electrochemical polarization method (전기화학적 분극법에 의한 1.0Cr-0.5Mo강의 경년열화 평가에 관한 연구)

  • Na, Eui-Gyun;Kim, Hoon;Lee, Jong-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.177-189
    • /
    • 1998
  • The contents of this paper include a non-destructive technique for evaluating the degradation of the boiler superheater tube in a fossil power plant through an electrochemical polarization test. Correlation between Ip of polarization parameter and SP-DBTT for the superheater tubes in long-term use was obtained. 1.0Cr-0.5Mo steel was degraded by softening, and the degree of degradation was dependent upon carbides with Cr and Mo elements. Since brittle fracture at low temperature and ductile fracture mode at high temperature were shown, similarity between standard Charpy and small punch tests could be found. In addition, SP-DBTT showing the degree of degradation was higher, as the time-in use of the materials got longer. Electrolyte including picric acid of 1.3 g in distilled water of 100ml at 25.deg. C temperature and sodium tridecylbenzene sulfonate with 1g could be applied to evaluate the degradation of 1.0Cr-0.5Mo steel by means of the electrochemical polarization test. Ip and Ipa values measured through the electrochemical test are the appropriate parameters for representing the degradation of the superheater tube(1.0Cr-0.5Mo steel) for the fossil power plant. It is poassible to evaluate the degradation of materials with different time histories electrochemically, by Ip value only, at field test.

Horner's Syndrome: A Rare Complication of Tube Thoracostomy - A case report - (폐쇄식 흉강삽관술 후 발생한 호너 증후군 - 치험 1예 -)

  • Choi, Jae-Woong;Kim, Joo-Hyun;Yoo, Byung-Su;Kang, Chang-Hyun;Kim, Young-Tae
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.816-819
    • /
    • 2010
  • We report one case of Horner's syndrome, a rare complication of closed thoracostomy. A 17 year-old girl with a second attack of left side primary spontaneous pneumothorax visited an emergency room. After closed tube thoracostomy, she was admitted to a general ward for elective video-assisted thoracosopic bullectomy, which was delayed due to incidental right side acute otitis media. On the third day of admission, she presented with pain and discomfort in the left eye. Further examination revealed left side ptosis and miosis and led to a diagnosis of Homer's syndrome. The chest tube was pulled back 2 to 3 cm for repositioning. After two days she underwent video-assisted thoracoscopic bullectomy and mechanical pleurodesis and was discharged at postoperative day 7. Symptoms and signs of Homer's syndrome gradually resolved, and she had fully recovered at the 2 month postoperative outpatient follow-up.