• Title/Summary/Keyword: Tube-by-Tube

Search Result 7,071, Processing Time 0.037 seconds

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Antibiotic Susceptibility of Bacteria Isolated from Infected Root Canals (감염근관에서 분리 배양한 세균의 수종 항생제에 대한 감수성 조사)

  • Lim, Sang-Soo;Kim, Mi-Kwang;Min, Jeong-Beom;Kim, Min-Jung;Park, Soon-Nang;Hwang, Ho-Keel;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.185-194
    • /
    • 2006
  • The aim of this study was to identify the bacteria isolated from endodontic lesions by cell culture and to determine the antimicrobial susceptibility of them against 8 antibiotics. The necrotic pulpal tissues were collected from 27 infected root canals, which were diagnosed as endodontic infection. Samples were collected aseptically from the infected pulpal tissue of the infected root canals using a barbed broach and a paper point. The cut barbed broaches and paper points were transferred to an eppendorf tube containing $500{\mu}l\;of\;1{\times}PBS$. The sample solution was briefly mixed and plated onto a BHI-agar plate containing 5% sheep blood. The agar plates were incubated in a $37^{\circ}C$ anaerobic chamber for 2 to 5 days. The bacteria grown on the agar plates were identified by comparison of 16S rRNA gene (rDNA) sequencing method at the species level. To test the sensitivity of the bacteria isolated from the infected root canals against 8 antibiotics, minimum inhibitory concentrations (MIC) were determined using broth dilution assay. The data showed that 101 bacterial strains were isolated and were identified. Streptococcus spp. (29.7%) and Actinomyces spp. (21.8%) were predominantly isolated. The 9 strains were excluded in antimicrobial susceptibility test because they were lost during the experiment or were not grown in broth culture. The percentage of bacteria susceptible for each antibiotic in this study was clindamycin, 87.0% (80 of 92); tetracycline, 75.0% (69 of 92); cefuroxime axetil, 75.0% (69 of 92); amoxicillin + clavulanic acid (5:1), 71.7% (66 of 92); penicillin G, 66.3% (61 of 92); erythromycin, 66.3% (61 of 92); amoxicillin, 44.6% (41 of 92); and ciprofloxacin, 31.5% (29 of 92). The susceptibility pattern of 8 antibiotics was dependent on the host of the bacteria strains rather than the kinds of bacterial species. These results indicate that antibiotic susceptibility test should be performed when antibiotics are needed for the treatment of infected root canals.

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.

Patient's Selection for Extracorporeal Shock Wave Lithotripsy for Treatment of Common Bile Duct Stones Resistant to Endoscopic Extraction (체외충격파쇄석술 적용을 위한 총담관결석의 선택)

  • Lee, Won-Hong;Son, Soon-Yong;Kim, Chang-Bok;Park, Cheon-Kyoo;Kang, Seong-Ho;Ryu, Meung-Sun;Lee, Yong-Moon
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.105-110
    • /
    • 2005
  • Background/Aim : Common bile duct (CBD) stones may cause jaundice, cholangitis, or pancreatitis. Extracorporeal shock wave lithotripsy (ESWL) may be needed whenever endoscopic procedure are failed to extract common bile duct stones. The aim of this study is to provide the standard for patient's best choice on ESWL for treatment of CBD stones resistant to endoscopic extraction. Materials and Methods : Fourty-six patients failed in endoscopic stone extraction including mechanical lithotripsy were treated by ESWL. In all patients, endoscopic sphincterotomy and nasobiliary drainage tube was done before ESWL using the ultrasonography for stone localization with a spark-gap type lithotriptor. Patients were sedated with an intravenous injection of 50 mg of Demerol. None were treated under general anesthesia. Results : Overall complete clearance rate of CBD stone was 89.1% (41/46). In 82.6% of the patients, the stones were extracted endoscopically after ESWL, and spontaneous passage was observed in 6.5%. In the clearance rate after ESWL, there were no noticeable differences with regard to number (single: 82.8%, two or three: 100%, more than three: 100%) and size of the stone (less than 33mm: 92.9%, 33 mm or larger: 83.3%), whereas there were significant differences with regard to the ratio of sum of long-axis length of the all stones to sum of long-axis length of the CBD excluding stone (1:2.4, 1:2.1) and diameter of the largest stone to diameter of CBD excluding stone (1:0.9, 1:0.4) for patients with complete clearance compared with those without. Conclusion : We propose that stones without the fragments are travelable sufficient space in CBD or extractable sufficient diameter of CBD regardless of stone size and number should be treated by other technique to prevent time and cost consuming, such as percutaneous transhepatic cholangioscopylithotomy.

  • PDF

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Comparison of VATS with Thoracotomy for the Treatment of Spontaneous Pneumothorax (자발성 기흉의 치료에서의 비디오 흉강경 수술과 개흉술의 비교)

  • 김문수;김영태;김기봉;김원곤;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.294-298
    • /
    • 1999
  • Background: Video-assisted thoracoscopic surgery(VATS) has been established as a new method for treatment of spontaneous pneumothorax. We compared the clinical results of VATS with those of thoracotomy performed during the recent 5 years. Material and Method: We analyzed 126 patients whose medical records were available among the 154 patients who underwent operations for spontaneous pneumothorax from 1992 to 1996. The mean age was 27.1 years(15 to 75 years). 87 patients were operated on by VATS(Group A) and the other 39 by thoracotomy(Group B). The mean follow-up period was 14.7 months. Result: The operation time was shorter in group A than in group B(90.6${\pm}$38.6minutes: 117.2${\pm}$58.9minutes, p<0.05). The duration of postoperative hospital stay was shorter in group A than in group B(6.7${\pm}$4.2: 9.4${\pm}$3.3 days, p<0.05). The amount of analgesics(nalbuphin HCl, ketoprofen) used postoperatively were 2.4${\pm}$2.8 ampules in group A, which is less than the 6.5${\pm}$5.6 ampules in group B(p<0.05). The number of staples used in group A was smaller(2.7${\pm}$1.3 in group A, 1.76${\pm}$1.1 in group B, p<0.05). The duration of chest tube indwelling(4.3${\pm}$4.0 days in group A, and 5.6${\pm}$3.0 days in group B, NS), the recurrence rate(13.8% in group A, 2.6% in group B, NS), and the duration of air leakage(1.3${\pm}$3.3 days in group A, and 1.0${\pm}$2.5days in group B, NS) were not statistically different between the two groups. Conclusion: The application of VATS for the treatment of spontaneous pneumothorax has brought in better clinical results(shorter operation time, shorter hospital stay, less pain, and better cosmetic merits) than the thoracotomy without increasing any morbidity. However no advantages in recurrence rates and duration of postoperative air leakages are revealed.

  • PDF

Video-Assisted Thoracic Surgery Lobectomy: Experience with 36 Cases (비디오 흉강경을 이용한 폐엽절제술: 치험 36예)

  • Lee, Hee-Sung;Lee, Jae-Woong;Kim, Kun-Il;Cho, Sung-Woo;Park, Sang-Jun;Kim, Hyoung-Soo;Shin, Yoon-Cheol;Shin, Ho-Seung
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.732-737
    • /
    • 2009
  • Background: Many video-assisted thoracic surgery (VATS) lobectomies are performed as a potential alternative to thoracotomy despite the controversy about the safety and the associated morbidity/mortality rates. Material and Method: Between November 2006 and August 2008, we performed 87 lobectomies (VATS 36, Thoracotomy 51) and we retrospectively reviewed the surgical treatment results. A VATS lobectomy was performed by a 4~5 cm thoracotomy without rib spreading and this included anatomic hilar dissection, individual vessel and bronchus stapling and lymph node dissection. Result: We studied 52 male and 35 female patients whose age ranged from 6 to 79 (average age: $59.8{\pm}15.0$ years). The cases were diagnosed with lung cancer (66) (SQC 24, ADC 38, others 4), pulmonary metastasis (2), carcinoid (2) and benign diseases (17). There was no intraoperative death. Postoperative complications were seen in 5 (15.6%) VATS and 33 (64.7%) thoracotomies, and perioperative death caused by adult respiratory distress syndrome occurred in 1 (2.8%) VATS and 3 (5.9%) thoracotomies. Three patients Underwent conversion to thoracotomy (8.3%). The mean time to chest tube removal was 6 days for VATS and 9.4 days for thoracotomy (p<0.001), and the mean length of the hospital stay was 8 days for VATS and 12.8 days for thoracotomy (p<0.001). Conclusion: VATS lobectomy can be performed safely with low morbidity/mortality rates. Furthermore, all the patients benefited from earlier postoperative rehabilitation and less pain and they were candidates for an earlier return to normal activities.

The Use of Transmedia in Current Affairs Radio Shows Focusing on 'That Honey Show' of Kim Hyun-Jung's News Show(CBS) (라디오 시사프로그램의 트랜스미디어 활용 연구 - CBS <김현정의 뉴스쇼-댓꿀쇼>를 중심으로 -)

  • Shin, Jung-Ah;Han, Hee-Jeong
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.6
    • /
    • pp.35-54
    • /
    • 2021
  • This study examines the characteristics of CBS's Kim Hyun-Jung's News Show(hearafter News Show) and the change to transmedia. The distinguishing characteristics of News Show compared to radio-based current affairs programs are as follows. First, despite its time limit, it adopts the form of investigative reports or investigative documentaries to uncover the truth of the events through 'Detective Son Su-Ho', etc. Second, News show's interviews have avoided biased stance in the reporting of minority issues by interviewing the affected parties anonymously including people involved in incidents and accidents, bereaved families, and other victims. News Show has been producing a transmedia content called 'That Honey Show' (a show that reads comments as fun as honey) since November 2018. 'That Honey Show' is broadcast in real time on YouTube right after the News Show radio broadcast ends. As a form of spin-off content, 'That Honey Show' breaks down the boundaries among staff, MCs, and guests, as well as shifting roles by using 'vice characters'. The female host, Kim conducts interviews with the main characters related to various issues and extends the fixed identity of current affairs shows to the everyday politics and cultural realms. Thus she draws active participation and responses audience. This paper analyzes two representative broadcast cases of 'That Honey Show'-first, the case of resistance and activity of the BTS fandom ARMY in the US presidential election, and, second, the case of reporting on the Nth room incident. This analysis considers the critical participation of digital citizens and the effect of fostering a sense of community in the current affairs show in the transmedia era.

Flowering, Fertilization Characteristics and Speedy Breeding in a Protandry Plant Peucedanum japonicum Thunb. (웅예선숙 식물인 갯기름나물(식방풍)의 개화 특성 및 세대촉진 방법)

  • Jin Tae Kim;Ho Jun Joh;Hong Seob Yu;Young Sang Park;Ji-Seok Kim;Yong Hyeok Jeong;Tae-Jin Yang
    • Korean Journal of Plant Resources
    • /
    • v.36 no.4
    • /
    • pp.402-412
    • /
    • 2023
  • Peucedanum japonicum Thunberg is a biennial plant that usually flowers and dies after seed setting at 2nd year. We inspected the flowering and fertilization characteristics to establish the breeding system. The plant forms complex umbel inflorescences consisting of multiple umbellets and numerous flowers. Each flower is bisexual but allogamous because of protandry. A flower bloomed for three days with matured pollen and no stigma appearance. Inspection of pollen tube growth indicates that the pollen viability can be maintained for up to 3~7 days after first flowering (DAF). In a umbellet, flowers bloomed during 1~5 DAF and the pollen maintained viability during 3~10 DAF, and the pistil developed and maintained fertility during 8~12 DAF. Theoretically, self-pollination can be possible during 8~10 DAF in the same umbellet. Approximately 4.4% of seeds were developed by self-pollination among flowers in an enveloping solitary umbel. There is at least a 9~10 days difference for the development of an umbel with another umbel at the next branch, which indicates pollination can be permitted between different branches in an individual plant. Finally, we have established a rapid breeding method to shorten the breeding cycle to one year from two years by integrating the flowering and pollination characteristics.