• 제목/요약/키워드: Tube direction

검색결과 385건 처리시간 0.03초

실험적 치아 이동시 성견 치주조직의 변화에 대한 면역조직화학적 연구 (IMMUNOHISTOCHEMICAL STUDY ON THE PERIODONTAL TISSUE REACTION DURING EXPERIMENTAL TOOTH MOVEMENT IN THE ADULT DOG)

  • 김미정;양원식
    • 대한치과교정학회지
    • /
    • 제23권1호
    • /
    • pp.89-100
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of orthodontic force on periodontal cellular activity by immunoperoxidase stain of epidermal growth factor, one of the tissue hormone. And supplementarily, to investigate of the changes of periodontal structures, periodontium was stained by H-E, Masson's Trichrome, P. A. S. stain after orthodontic force application. The experimental animals were four young adult dogs of average 8 month old. The fixed orthodontic appliance was cemented on mandibular right 4th premolar and 1st molar of each animal as experimental site. Mandibular left 4th premolar area of the same animal was used as control. The appliance consist of two silver crown soldered with 0.030' tube, $0.018\times0.022'$ S.S. sectional arch wire, and 0.009' open coil spring for manifestating of orthodontic force for bodily tooth movement of mandibular 4th premolar toward mesial direction. Experimental group was sacrificed at 1, 2, 3, 5 weeks from beginning of the experiment, and was investigated immunohistochemically and bistochemically by several staining methods. Findings were as follows: 1. The degree of EGF staining in control group was highest in epithelium of periodontium, and osteoclasts, osteoblasts and fibroblasts around the capillary were stained at higher level in periodontium. Generally, control group shows positive distribution of EGF all around the periodontal area. 2. The degree of EGF staining in control and 5 week group were similar, and did not show the significant different level between tension and pressure side. 3. All of 1, 2, 3 week group showed the same staining degree and distribution of EGF, and the tension side was more positive reaction of EGF stain than the pressure side. 4. The features of collagen fiber and periodontal fiber arrangement observed by H-E, Masson's Trichrome and P. A. S. stain revealed that oblique periodontal fibers were strectched in tension side, compressed in pressure side of all experimental group. Some fiber group in pressure side of 5 week group recovered the regular arrangement along the capillaries.

  • PDF

A Study on the Development Direction and Cognition of Viral Video

  • Lee, Yong-Whan
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권7호
    • /
    • pp.65-73
    • /
    • 2020
  • 바이럴 영상광고는 광고 및 영화산업에서 특정제품이나 개봉전 영화에 대한 사전 홍보 목적으로 활용되고 있으며, 투자 대비 많은 효과를 내고 있다. 향후 발전 방향을 예측해 보려면 바이럴 영상 인식에 대한 분석이 필요하다. 이에 본 연구는 광고나 영화를 가장 많이 접하는 연령층인 20대 대학생 118명에 대한 바이럴 영상 설문조사를 하였다. 이를 통해 바이럴 영상에 대한 인지 여부, 기억에 남는 바이럴 영상, 만족도, 메시지 전파여부, 전파 방식, 바이럴 영상에 대한 긍정도, 향후 발전 예상, 희망하는 바이럴 영상 유형 등에 대한 설문을 실시하였다. 이 결과 바이럴 영상 인지도는 16.7%로 나타났고, 가장 기억에 남는 바이럴 영상으로 "겨울왕국" 영화의 "Let it Go" 영상이 설문조사 결과 69.1%로 나타났다. 바이럴 영상에 대한 만족도는 31.2%로 높지 않았으며, 바이럴영상을 시청한 후 타인에게 메시지를 전달한 경우는 73.5%로 높게 나타났다. 바이럴 영상에 대한 부정적 의견은 13.7%로 낮게 나타났으며, 바이럴 영상 분야가 64.5%는 "발전할 것이다"라고 답하였고, 6.7%는 "발전하지 못할 것이다"라고 답하였다.

Material Properties of Ni-P-B Electrodeposits for Steam Generator Tube Repair

  • Kim, Dong Jin;Seo, Moo Hong;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • 제3권3호
    • /
    • pp.112-117
    • /
    • 2004
  • This work investigated the material properties of Ni-P-B alloy electrodeposits obtained from a Ni sulfamate bath as a function of the contents of the P and B sources($H_3PO_3$ and dimethyl amine borane complex(DMAB), respectively) with/without additives. Chemical composition, residual stress, microstructure and micro hardness were investigated using ICP(inductively coupled plasma) mass spectrometer, flexible strip, XRD, TEM and micro Vickers hardness tester, respectively. From the results of the compositional analysis, it was observed that P and B are incorporated competitively during the electrodeposition and the sulfur from the additive is codeposited into the electrodeposit. The measured residual stress value increased in the order of Ni, Ni-P, Ni-B and Ni-P-B electrodeposits indicating that boron affects the residual tensile stress greater than phosphorus. As the contents of the alloying element sources of P and B increased, crystallinity and the grain size of the electrodeposit decreased. The effect of boron on crystallinity and grain size was also relatively larger than the phosphorus. It can be explained that the boron with a smaller atomic radius contributes to the increase of residual stress in the tensile direction and the larger restraining force against the grain growth more significantly than the phosphorus with a larger atomic radius. Introduction of an additive into the bath retarded crystallization and grain growth, which may be attributed to the change of the grain growth kinetics induced by the additive adsorbed on the substrate and electrodeposit surfaces during electrodeposition.

Field-Aided Micro-Tailoring에 의한 기능성 나노복합재 제조 (Manufacturing Functional Nano-Composites by Using Field-Aided Micro-Tailoring Manipulation)

  • 조희근;이주훈;심은섭
    • Composites Research
    • /
    • 제25권6호
    • /
    • pp.178-185
    • /
    • 2012
  • 본 연구에서는 기능성 나노복합재를 제작하는 방법이 제시되었다. 미소 입자들을 포함하고 있는 점성을 가진 유체에 전기장을 가하여 유체속에 포함된 입자들을 전기장의 방향에 따라 규칙적으로 배열을 하였다. FAiMTa 기술이라고 불리는 이 방법은 마이크로 혹은 나노 사이즈의 입자들을 체인의 형태로 배열하여 직교이방성 폴리머 나노복합재의 제작을 가능하게 하였다. 알루미나($Al_2O_3$), 탄소나노튜브(CNT), 탄소(Graphite), 텅스텐(W) 등의 마이크로 혹은 나노 사이즈 입자 분말을 사용하여 FAiMTa기술의 유효성을 확인하는 시험을 수행하였다. 이러한 입자들을 전기장을 사용하여 일정한 방향으로 배열하여 직교이방성 폴리머 복합재를 만들었고, 시험시편의 물리적 특성 즉 기계적 열적 특성을 측정하여 방향성을 확인하였다. 이렇게 제작된 첨단 나노복합재는 각종 산업분야에서 큰 효과가 기대된다.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

Numerical Simulation of the Effects of Moisture on the Reinforcement of a Tropopause Fold

  • Lee, Hong-Ran;Kim, Kyung-Eak;Lee, Yong-Hee
    • 한국지구과학회지
    • /
    • 제30권5호
    • /
    • pp.630-645
    • /
    • 2009
  • The tropopause fold event that took place on January 1, 1997 over mid-region on the Korean Peninsula is examined by means of a numerical simulation based on a Mesoscale Model (MM5). The purpose of this paper is to investigate the effects of moisture in reinforcing a tropopause fold linked to an explosive cyclone. Two types of simulations were carried out; 1) simulations for moist conditions in which full physical and dynamic processes are considered and 2) simulations for dry conditions in which cumulus parameterization and cloud microphysics process are excluded. The results of the moist condition simulations demonstrate that the intensity of the central pressure of the cyclone was overestimated compared with the observed values and that the location of the center and the pressure deepening rates (-17 hPa/12 hr) complied with the observed values. The potential vorticity (PV) anomaly on the isentropic surface at 305 K continued to move in a southeast direction on January 1, 1997 and thus created a single tube of tropopause fold covering the northern and the middle area of the Korean Peninsula and reaching the ground surface at 0300 UTC and 0600 UTC. The results of the dry condition simulations show that the tropopause descended to 500 and 670 hPa in 0300 and 0600 UTC, respectively at the same location for the moist condition simulation; however, there was no deep tropopause fold observed. A comparison of the simulated data between the moist and the dry conditions suggests that a deep tropopause fold should happen when there is sufficient moist in the atmosphere and significantly large PV in the lower atmosphere pulls down the upper atmosphere rather than when the tropopause descends itself due to dynamic causes. Thus, it is estimated that moisture in the atmosphere should have played a crucial role in a deep tropopause fold process.

와류 챔버를 사용하는 호흡기류 센서 (Air flow transducer with turbulence chamber)

  • 이인광;최성수;김군진;장종찬;김성식;김경아;이태수;차은종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1971-1972
    • /
    • 2008
  • Cardiopulmonary resuscitation(CPR) is an important clinical technique performing artificial ventilation and chest compression on a patient under emergent situation before arriving in hospital. Since the quality of CPR significantly affects the survival rate, it would be of great advantage to monitor respiration in real time during CPR. However, currently applied respiratory air flow transducers are difficult to apply with sensing elements in the middle of the flow axis. The present study developed a new turbulent air flow transducer conveniently applicable to CPR. Abrupt changes in diameter of the flow tube generated turbulence in air flow, thereby pressure difference was obtained to estimate the air flow rate, with no physical object on the flow plane. Expiration and inspiration were separated by the direction of the pressure difference, resulting in good symmetry. Pressure-flow relationship was tested on a quadratic model, which provided accurate enough estimation results. Therefore, the present turbulent air flow transducer seemed appropriate to monitor respiration during CPR.

  • PDF

Biomechanical considerations for uprighting impacted mandibular molars

  • Morita, Yukiko;Koga, Yoshiyuki;Nguyen, Tuan Anh;Yoshida, Noriaki
    • 대한치과교정학회지
    • /
    • 제50권4호
    • /
    • pp.268-277
    • /
    • 2020
  • This case report demonstrates two different uprighting mechanics separately applied to mesially tipped mandibular first and second molars. The biomechanical considerations for application of these mechanisms are also discussed. For repositioning of the first molar, which was severely tipped and deeply impacted, a novel cantilever mechanics was used. The molar tube was bonded in the buccolingual direction to facilitate insertion of a cantilever from the buccal side. By twisting the distal end of the cantilever, sufficient uprighting moment was generated. The mesial end of the cantilever was hooked over the miniscrew placed between the canine and first premolar, which could prevent exertion of an intrusive force to the anterior portion of the dentition as a side effect. For repositioning of the second molar, an uprighting mechanics using a compression force with two step bends incorporated into a nickel-titanium archwire was employed. This generated an uprighting moment as well as a distal force acting on the tipped second molar to regain the lost space for the first molar and bring it into its normal position. This epoch-making uprighting mechanics could also minimize the extrusion of the molar, thereby preventing occlusal interference by increasing interocclusal clearance between the inferiorly placed two step bends and the antagonist tooth. Consequently, the two step bends could help prevent occlusal interference. After 2 years and 11 months of active treatment, a desirable Class I occlusion was successfully achieved without permanent tooth extraction.

THE EFFECTS OF CREEP AND HYDRIDE ON SPENT FUEL INTEGRITY DURING INTERIM DRY STORAGE

  • Kim, Hyun-Gil;Jeong, Yong-Hwan;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.249-258
    • /
    • 2010
  • Recently, many utilities have considered interim dry storage of spent nuclear fuel as an option for increasing spent fuel storage capacity. Foreign nuclear regulatory committees have provided some regulatory and licensing requirements for relatively low- and medium-burned spent fuel with respect to the prevention of spent fuel degradation during transportation and interim dry storage. In the present study, the effect of cladding creep and hydride distribution on spent fuel degradation is reviewed and performance tests with high-burned Zircaloy-4 and advanced Zr alloy spent fuel are proposed to investigate the effect of burnup and cladding materials on the current regulatory and licensing requirements. Creep tests were also performed to investigate the effect of temperature and tensile hoop stress on hydride reorientation and subsequently to examine the temperature and stress limits against cladding material failure. It is found that the spent fuel failure is mainly caused by cladding creep rupture combined with mechanical strength degradation and hydride reorientation. Hydride reorientation from the circumferential to radial direction may reduce the critical stress intensity that accelerates radial crack propagation. The results of cladding creep tests at $400^{\circ}C$ and 130MPa hoop stress performed in this study indicate that hydride reorientation may occur between 2.6% to 7.0% strain in tube diameter with a hydrogen content range of 40-120ppm. Therefore, it is concluded that hydride re-orientation behaviour is strongly correlated with the cladding creep-induced strain, which varies as functions of temperature and stress acting on the cladding.

Wave propagation in a concrete filled steel tubular column due to transient impact load

  • Ding, Xuanming;Fan, Yuming;Kong, Gangqiang;Zheng, Changjie
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.891-906
    • /
    • 2014
  • This study aims to present a three dimensional finite element model to investigate the wave propagation in a concrete filled steel tubular column (CFSC) due to transient impact load. Both the concrete and steel are regarded as linear elastic material. The impact load is simulated by a semi sinusoidal impulse. Besides the CFSC models, a concrete column (CC) model is established for comparing under the same loading condition. The propagation characteristics of the transient waves in CFSC are analyzed in detail. The results show that at the intial stage of the wave propagation, the velocity waves in CFSC are almost the same as those in CC before they arrive at the steel tube. When the waves reach the column side, the velocity responses of CFSC are different from those of CC and the difference is more and more obvious as the waves travel down along the column shaft. The travel distance of the wave front in CFSC is farther than that in CC at the same time. For different wave speeds in steel and concrete material, the wave front in CFSC presents an arch shape, the apex of which locates at the center of the column. Differently, the wave front in CC presents a plane surface. Three dimensional effects on top of CFSC are obvious, therefore, the peak value and arrival time of incident wave crests have great difference at different locations in the radial direction. High-frequency waves on the waveforms are observed. The time difference between incident and reflected wave peaks decreases significantly with r/R when r/R < 0.6, however, it almost keeps constant when $r/R{\geq}0.6$. The time duration between incident and reflected waves calculated by 3D FEM is approximately equal to that calculated by 1D wave theory when r/R is about 2/3.