Effect of Low Night Temperature on Reproductive Organ Development in Relation to Pollen Viability of Bell Pepper (야간 저온조건이 파프리카 화분 활력 및 생식기관 발달에 미치는 영향)

  • Lim, Chae-Shin
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.581-586
    • /
    • 2009
  • Bell pepper plants (Capsicum annuum cv. Plenty) were grown under low night temperatures (LNT: day/night temperature of $28/13^{\circ}C$) and optimum night temperatures (ONT: day/night temperature of $28/20^{\circ}C$) in growth chambers. Pollen grains were collected from plants in the growth chamber and incubated at 10, 15, 20, 25, and $30^{\circ}C$. After 24 hr incubation, in both ONT and LNT, the highest percent pollen germinations were observed at $25^{\circ}C$ followed by germinations at $30^{\circ}C$. Percent pollen germination at $25^{\circ}C$ was 42% in ONT - two times higher than in LNT at 21%. Pollen tube length was much longer at ONT than at LNT, regardless of incubation temperature. Compared with other treatments, earlier and quicker pollen tube elongation was observed in ONT pollen grains incubated at $25^{\circ}C$. To find pollen viability in plant growing conditions, pollen grains were incubated in LNT ($28/13^{\circ}C$) and ONT ($28/20^{\circ}C$) growth chambers for 24 hr. Petri-dishes with pollen grains were put in the growth chambers at the beginning of the night condition. Pollen grains in the LNT growth chamber did not germinate at night ($13^{\circ}C$), but began to germinate when the day condition ($28^{\circ}C$) started. Pollen grains in the ONT condition, however, started germinating from the early night ($20^{\circ}C$) and germination continued during the day ($28^{\circ}C$). Plants in LNT showed increased flower stalk length, ovary diameter, stamen length, flower weight, and fruit length. LNT conditions did not impair seed set. There were no differences in seed sets between fruits at LNT and ONT. Normal seed sets in LNT show that fertilization may be completed during daytime. However, further investigation is needed to find what extent of temperature stress causes malformed and/or parthenocarpic fruits in this bell pepper.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen (경추 추간공 관찰을 위한 촬영법의 고찰)

  • Jeon, Ju-Seob;Eun, Sung-Jong;Kim, Hye-Ran;An, Seung-Hyun;Choi, Nam-Kin;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • The cervical spine of anteroposterior oblique view is essential to observe the intervertebral foramen(IVF). The morphologic changes of IVFs were proved to be abnormal with nerve roots and peripheral structures. The purpose of this study is to evaluate the effective projection angle for observing the IVFs in the Korean adults. In a prospective clinical study of 100 normal persons, $45^{\circ}$, $50^{\circ}$ and $55^{\circ}$ oblique views were compared by measuring the maximal transverse diameter of all the cervical IVFs. $45^{\circ}$ oblique views provided slightly better visualization of upper cervical level(C2-C3, C3-C4, C4-C5), but the lower cervical level(C5-C6, C6-C7, C7-T1) of IVF transverse diameters were substantially increased on the $55^{\circ}$ AP oblique projection. In the comprasion of mean differences between 8 obese person(BMI > 25) and 58 normal person(18.5 < BMI < 22.9) proved to be statistically not significant. Consequently this study shows that $55^{\circ}$AP oblique(tube angle $15^{\circ}$cephalad) view is optimal for evaluating the lower cervical IVFs.

  • PDF

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF

Patient's Selection for Extracorporeal Shock Wave Lithotripsy for Treatment of Common Bile Duct Stones Resistant to Endoscopic Extraction (체외충격파쇄석술 적용을 위한 총담관결석의 선택)

  • Lee, Won-Hong;Son, Soon-Yong;Kim, Chang-Bok;Park, Cheon-Kyoo;Kang, Seong-Ho;Ryu, Meung-Sun;Lee, Yong-Moon
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.105-110
    • /
    • 2005
  • Background/Aim : Common bile duct (CBD) stones may cause jaundice, cholangitis, or pancreatitis. Extracorporeal shock wave lithotripsy (ESWL) may be needed whenever endoscopic procedure are failed to extract common bile duct stones. The aim of this study is to provide the standard for patient's best choice on ESWL for treatment of CBD stones resistant to endoscopic extraction. Materials and Methods : Fourty-six patients failed in endoscopic stone extraction including mechanical lithotripsy were treated by ESWL. In all patients, endoscopic sphincterotomy and nasobiliary drainage tube was done before ESWL using the ultrasonography for stone localization with a spark-gap type lithotriptor. Patients were sedated with an intravenous injection of 50 mg of Demerol. None were treated under general anesthesia. Results : Overall complete clearance rate of CBD stone was 89.1% (41/46). In 82.6% of the patients, the stones were extracted endoscopically after ESWL, and spontaneous passage was observed in 6.5%. In the clearance rate after ESWL, there were no noticeable differences with regard to number (single: 82.8%, two or three: 100%, more than three: 100%) and size of the stone (less than 33mm: 92.9%, 33 mm or larger: 83.3%), whereas there were significant differences with regard to the ratio of sum of long-axis length of the all stones to sum of long-axis length of the CBD excluding stone (1:2.4, 1:2.1) and diameter of the largest stone to diameter of CBD excluding stone (1:0.9, 1:0.4) for patients with complete clearance compared with those without. Conclusion : We propose that stones without the fragments are travelable sufficient space in CBD or extractable sufficient diameter of CBD regardless of stone size and number should be treated by other technique to prevent time and cost consuming, such as percutaneous transhepatic cholangioscopylithotomy.

  • PDF

A study on establishing asbestos analysis method using a transmission electron microscope with Energy dispersive X-ray analyzer (TEM-EDX) (에너지 분산 X선 분석장치가 장착된 투과전자현미경을 이용한 석면분석방법)

  • Han, Jeong Hee;Kim, Kwang Jin;Chung, Yong Hyun;Lee, Jun Yeon;Lee,, Yong;Chung, Ho Keun;Yu, Il Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.102-110
    • /
    • 2001
  • To establish an accurate asbestos analysis method for workplace samples, chrysotile, amosite, crocidolite, tremolite, actinolite, and anthophyllite asbestos fibers were analyzed for their morphology, atomic content and electron diffraction patterns. The morphology of asbestos fiber was evaluated in $10,000{\times}$ magnification. The atomic contents was analyzed by X-ray analyzer (TEM-EDX). Asbestos fibers were further assessed using electron diffraction (ED) patterns to provide an additional criterion for classifying the asbestos fibers. Twenty asbestos fibers were initially randomly selected for morphological evaluation; based on an aspect ratio (length : diameter = 3:1). Then the fibers were determined for their EDX spectrums and ED patterns. Our results showed that only chrysotile fiber has a hollow tube structure to be distinguished from other asbestos fibers. Although asbestos fibers had similar morphology, they had different EDX spectrums and ED patterns. Our results on the atomic content of asbestos fibers were very similar to those of other researchers, but amosite and crocidolite had a little difference in atomic content compared with the results from other researchers. The difference may be due to the difference in equipment or asbestos sample selection. A study on asbestos samples from biological specimens to establish a criterion for determining occupational asbestos exposed diseases should be done in the near future.

  • PDF

Vertical Upward Air-Water Two-Phase Flow Regime Identification (수직상향류 공기-물 이상유동영역 판별)

  • Lee, Ba-Ro;Jang, Young-Jun;Ko, Min-Seok;Lee, Bo-An;Lee, Yeon-Gun;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • Two-phase flow is frequently observed in many industries such as nuclear power plants and oil transportation. Two-phase flow regime depends on the flow rates, the fluid properties and the structure of flow channels. Since the identification of the flow regime is of great importance in the system design and the safety analysis, a number of theoretical and experimental investigations have been performed. This paper presents a basic research on the characteristics of each flow regime and transition boundary in the two-phase flows. The flow regime of the upward air-water flow in the vertical tube, 30 mm in the inner diameter, is distinguished by using the high-speed camera and the Wire-mesh sensor(WMS). The identified experimental data are compared with the flow regime maps proposed by Taitel et al, Mishima and Ishii. Even though there is slight difference in the transition boundary, the experimental data show general agreement with these flow regime maps.

Decomposition Process of CFC by Thermal Plasma (열플라즈마에 의한 CFC의 분해공정)

  • Cha, Woo-Byoung;Choi, Kyung-Soo;Park, Dong-Wha
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.829-834
    • /
    • 1998
  • Concerned with environmental issue, a new decomposition method for CFCs that caused the destruction of ozone layer was proposed. Using thermal plasma process, CFC113 decomposed completely. In order to quantify the tendency in decomposition and recombination of CFC113, thermodynamic equilibrium calculations were performed. The calculation was conducted with CFC113, $H_2$, $O_2$ at 1 atm and 300 K~5000 K. In the experiment, products which are generated after decomposition in the plasma were examined by varying reacting gases($H_2$, $O_2$) flow rates and the changes of inside diameters of quenching tubes. Decomposition products were analyzed using Gas Chromatograph. The results are very promising with a decomposition efficiency greater than 99.99%. As to CFC113/$H_2$=1/3, conversion to CO decreased with increasing $O_2$ ratio. When CFC113/$O_2$=1/1, 1/1.5 and 1/2, conversion to CO increases above $H_2$ ratio of 3. The change of CO conversion is not sensitive to power changes. As total flow rate increased, CO conversion was slightly decreased. When the inside diameter of the quenching tube was changed from 8mm into 4mm, CO conversion was increased due to enhanced quenching rate.