• 제목/요약/키워드: Tube current

검색결과 921건 처리시간 0.028초

평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석 (FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube)

  • 강경호;윤병조;어동진;백원필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

YouTube as a source of information about rubber dam: quality and content analysis

  • Gulsen Kiraz;Arzu Kaya Mumcu;Safa Kurnaz
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.10.1-10.8
    • /
    • 2024
  • Objectives: This study aimed to evaluate the content, quality and demographics of YouTube videos about rubber dam as an information source for clinicians and dental students. Materials and Methods: "Rubber dam," "rubber dam application," "dental isolation," "rubber dam isolation," and "dental dam" were determined as keywords for the detection of YouTube videos related to rubber dam. Seventy 3 videos were evaluated and a total of 34 videos met the inclusion criteria. All selected videos were evaluated according to 8 parameters. The videos were scored 1 if the videos contained information about the selected parameter, but if the videos did not contain enough information, they were scored 0. The data were statistically analyzed with the analysis of variance and post hoc Tukey test (p < 0.05). Results: We found that 41% of the videos have poor, 47% have moderate, and 12% have good information. There is a statistically significant difference in time between poor and good information content (p < 0.05). There is a statistically significant difference between the poor and good information in the video information and quality index 1. Conclusions: Rubber dam-related videos available on YouTube are generally moderately informed and insufficient. YouTube is currently not sufficient as a source of information for patients and clinicians at the moment. The YouTube platform should be developed and enriched with quality information on current and dental issues.

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

근접한 두 신호원에 의한 와전류 신호의 간섭 효과 (An Interaction Effect of Eddy Current Signals Due to the Neighboring Signal Sources)

  • 정용무
    • 비파괴검사학회지
    • /
    • 제11권1호
    • /
    • pp.7-12
    • /
    • 1991
  • The multi-frequency eddy current technique has been used for evaluation of various type of defects in tubings. However, this technique is not sufficient to detect and evaluate the defect in tubings if the defect is located in the geometrically complicated area(e. g. tube support plate, anti-vibration bar, tubesheet area) and mixing residue signal is significant to the defect signal. In order to improve the reliability of the multi-frequency eddy current technique, the effect of the interaction of mixing residue after frequency mixing with a function of distances between the defect and the tube support plate boundary has been analyzed theoretically. The experimental results have been discussed with the theoretical developments. The calculation shows the interaction between the two neighboring signal sources could be significant within the range of approximately 1.0mm with the experimental condition.

  • PDF

경계요소법을 이용한 축대칭 결함을 갖는 도체관에 대한 와전류탐상 수치해석 (Numerical Analysis of Eddy Current Testing for Tube with Axi-symmetric Defect using Boundary Element Method)

  • 서장원;이향범;윤만식;임의수;정태언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.748-750
    • /
    • 2001
  • This paper describes numerical analysis of eddy current testing for tube with axi-symmetric defect using boundary element method. In this ECT(Eddy Current Testing) numerical analysis. BEM and FEM are used to compare their characteristics and results of ECT, respectively BEM is easier than FEM to design geometrically complex domain because in case of BEM, domain is divided into segments or elements, but in case of FEM, domain is divided into small finite triangular or quadrilateral elements. For this reason asymmetry defect is used for this BE numerical analysis. As a result, the similar result can be obtained through both numerical analyses, and BEM can be applied to the numerical analysis of ECT.

  • PDF

와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析) (Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing)

  • 정태언;장기옥;박대영
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

CFD Simulation Tool for Anode-Supported Flat-Tube Solid Oxide Fuel Cell

  • Youssef M. Elsayed.;Lim, Tak-Hyoung;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul
    • 전기화학회지
    • /
    • 제9권4호
    • /
    • pp.151-157
    • /
    • 2006
  • A two-dimensional numerical model to study the performance of anode-supported flat-tube solid oxide fuel cell (SOFC) far the cross section of the cell in the flow direction of the fuel and air flows is developed. In this model a mass and charge balance, Maxwell-Stefan equation as well as the momentum equation by using, Darcy's law are applied in differential form. The finite element method using FEMLAB commercial software is used for meshing, discritization and solving the system of coupled differential equations. The current density distribution and fuel consumption as well as water production are analyzed. Experimental data is used to verify a predicted voltage-current density and power density versus current density to judge on the model accuracy.

증기발생기 전열관의 비파괴 탐상용 차등형 와전류 탐촉자 개발 (Development of Differential Type Eddy Current Probe for NDT Evaluation of the Steam Generator Tube)

  • 정선영;손대락;유권상;박덕근
    • 한국자기학회지
    • /
    • 제15권5호
    • /
    • pp.292-297
    • /
    • 2005
  • 원자력 발전소 증기발생기의 전열관은 전열면으로서의 역할과 방사능 차단벽의 역할로서 중요하며, 증기발생기 튜브의 폭발은 원자력 발전소 사고에 관계된다. 증기발생기 전열관 재료로는 Incone1600이 사용되고 있으며, 이 재료가 금속이면서 비자성이기 때문에 와전류 탐상법으로 전열관의 결함을 탐지하고 있다. 본 연구에서는 탐상 감도를 향상시키기 위하여 차등형 와전류 탐촉자를 개발하였으며, 개발된 차등형 와전류 탐촉자의 성능검사를 위해 Inconel600과 자기적 성질이 비슷하고 구하기 쉬운 SUS304로 가로 100mm, 세로 100mm, 그리고 두께 10mm인 평판에 선형결함과 원형결함을 가공하여 기준시편으로 제작하였다. 제작된 차등형 와전류 탐촉자를 사용하여, 자화주파수 50kHz, lift-off 0.4mm에서 직경이 0.25mm이고, 깊이가 0.2mm 크기의 결함까지 측정이 가능하였다.

CFRP 튜브의 결함형상.결함깊이.레이디얼 하중에 따른 와전류 신호의 변화 (Variation of Eddy Current Signal According to the Defect Shape, Defect Depth and Radial Load in CFRP Tube)

  • 송삼홍;안형근;이정순;오동준;송일;김철웅
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.2004-2011
    • /
    • 2004
  • The applicability of the ultrasonic C-scan inspection is restricted due to the deterioration of mechanical properties of specimen during the test. Therefore, the aim of this research is applied to Eddy Current (EC) test substitute for the C-scan inspection in CFRP tube containing defects. This research is to evaluate the EC signals for the inspection of CFRP tube containing various circular hole defects (20% to 100% depth to the specimen thickness) using the unloading specimen and radial loading specimen. This study was considered the following points; 1) Analysis of EC signals for the inspection of saw-cut defect and circular hole defect, 2) The evaluation of defect depths and EC signals relationship. 3) Variation of EC signal owing to the radial load. In conclusions, the high frequency such as 300∼500 kHz made it possible to the inspection of 40% to 100% defects. Particularly, in case of 20% defect, the EC signal was not detected due to the noise of micro-crack and delamination. While the depth of the hole defects were decreasing, the difference of the phase angle between unloading specimen and radial loading specimen was gradually increasing.