• Title/Summary/Keyword: Tube connection

Search Result 189, Processing Time 0.021 seconds

A Study on IP Camera Security Issues and Mitigation Strategies (IP 카메라 보안의 문제점 분석 및 보완 방안 연구)

  • Seungjin Shin;Jungheum Park;Sangjin Lee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.3
    • /
    • pp.111-118
    • /
    • 2023
  • Cyber attacks are increasing worldwide, and attacks on personal privacy such as CCTV and IP camera hacking are also increasing. If you search for IP camera hacking methods in spaces such as YouTube, SNS, and the dark web, you can easily get data and hacking programs are also on sale. If you use an IP camera that has vulnerabilities used by hacking programs, you easily get hacked even if you change your password regularly or use a complex password including special characters, uppercase and lowercase letters, and numbers. Although news and media have raised concerns about the security of IP cameras and suggested measures to prevent damage, hacking incidents continue to occur. In order to prevent such hacking damage, it is necessary to identify the cause of the hacking incident and take concrete measures. First, we analyzed weak account settings and web server vulnerabilities of IP cameras, which are the causes of IP camera hacking, and suggested solutions. In addition, as a specific countermeasure against hacking, it is proposed to add a function to receive a notification when an IP camera is connected and a function to save the connection history. If there is such a function, the fact of damage can be recognized immediately, and important data can be left in arresting criminals. Therefore, in this paper, we propose a method to increase the safety from hacking by using the connection notification function and logging function of the IP camera.

The Effect of Curvature Radius and Material of Diaphragm on the Valve Opening Time in Diaphragm Type S/R Valve (S/R 밸브에서 격막의 곡률반경과 재료가 밸브 개구시간에 미치는 영향)

  • Cheon, Heung-Kyun;Hwang, Jae-Gun;Cho, Tae-Seok;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2961-2966
    • /
    • 2007
  • When the pressure at the weak spot established at a certain part of a high pressure vessel or piping system exceeds a design pressure, this weak spot is burst, and the pressurized gas emitted through the weak spot will cause a compression wave system. In this connection, in the present study, an experimental study by using a conventional shock tube facility is performed to estimate the effects of the material of diaphragm, curvature radius and thickness of materials on the valve opening time in diaphragm. Pressure sensor having 500kHz in natural frequency is installed at 35mm downstream of the rupture diaphragm to measure the static pressure history of propagating and being accumulated compression wave. 4 kinds of materials are used as diaphragm that is aluminium, copper, stainless steel and zinc. The diaphragm radii of curvature R are ${\infty}$, 120mm and 60, respectively. And the depth for $90^{\circ}$ groove is 0.04mm. It is found that the smaller the tensile strength and elongation of the rupture diaphragm is, the smaller the radius of curvature of the rupture diaphragm is, and for the same conditions the thinner the thickness of the rupture diaphragm is, the shorter the valve opening time becomes. Also, the tensile strength, elongation and the radius of curvature of the rupture diaphragm for the same conditions are smaller, the maximum pressure rise caused by the coalescences of the compression wave is smaller. Finally the pressure ratio is higher, the valve opening time is shortened and gradient of pressure increment is more steepen.

  • PDF

Neuronal activity in the periaqueductal gray associated with chronic cannula implantation and microdialysis (Chronic cannula implantation 및 microdialysis가 periaqueductal gray내 신경세포 활성에 미치는 영향)

  • Lee, Jang-hern;Han, Ho-jae;Yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.720-729
    • /
    • 1998
  • Immunohistochemical technique of the c-fos primary gene protein, Fos, was used to analyze the effects of external factors on the neuronal activities in the periaqueductal gray(PAG) of the intact rats, sham-operated rats and post-operated stress control rats. In addition, the number of Fos positive neurons has been evaluated to verify the effects of cannula implantation and veratridine treatment on the neuronal activities in PAG area. The results were summerized as follow : 1. There was no significant difference in the number of Fos positive neurons observed in the caudal and middle portion of lateroventral PAG from cannula implanted rats and sham operated rats. 2. The number of Fos positive neurons in the PAG was not changed by the stress induced by connection of collecting tube to rats for 12 hours as compared to that of intact rats. 3. In the saline treated group, the Fos immunoreactivity in the PAG did not changed at 30 minutes and 1 hour after saline treatment as compared to that of intact rats. However, the number of Fos positive neurons was significantly increased at 2 hours after treatment compared to that of saline treated rats at 30 minutes after treatment. 4. The Fos immunoreactivity was dramatically increased at 30 minutes, 1 hour and 2 hours after veratridine treatment as compared to those of saline treated groups. The number of Fos immunoreative neurons showed the maximal level at 2 hours after veratridine treatment. 5. The Fos positive neurons induced by saline and veratridine treatment were mainly distributed in front of the microdialysis window. These results suggest that new microdialysis demonstrated in this study improves efficiency and accuracy to confine the neuronal activity in front of microdialysis window site. Moreover, this directional specificity allows us to locate probe tips adjacent to the brain area of the interest site rather than centering the probes within that brain area. Finally, This microdialysis method can be used to dialyse the neurotransmitters using concious and freely moving rats.

  • PDF

New Micro Rotating Mercury Electrode for Voltammetry (전류전압법을 위한 미크로 회전수은 전극)

  • Choe, Gyu-Won
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.81-84
    • /
    • 1967
  • A simple rotating micro mercury electrode is constructed in such a way that the mercury surface can be renewed quite easily with reasonable reproducibility. It consists of a glass capillary of about 1mm diameter connected to a mercury filled tube by means of a ground joint that allows mercury flow at a particular relative position only, and the electrical connection between the two parts is made by a platinum wire fused in the bottom of the latter. Thus the mercury surface exposed at the tip of the capillary replaces the platinum tip of the usual platinum micro electrode; however, the capillary has to be bent so that the tip directs upwards. It has been found to be a convenient electrode in the amperometric titration in strongly acidic media. Furthermore, it has been advantageously used in the alternating-current polarography because of its smaller electrical resistance than the ordinary dropping mercury electrodes. It also can be used as a stationary mercury electrode in fast scanning polarography.

  • PDF

Risk Assessment of Submerged Floating Tunnels based on Fuzzy AHP (퍼지 AHP를 이용한 수중터널의 재해위험도 분석)

  • Han, Sang-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3244-3251
    • /
    • 2012
  • In the construction and operation of large marine structure, hazard risk analysis is one of important factors. Therefore, this paper investigates the hazard risk indexes and evaluates the risk level in the construction and operation of SFT on the basis of expert survey and Fuzzy analytic hierarchy process. Hazard risk is divided into natural hazard risk (earthquake, typhoon, tsunami, and ice collision) and human factor hazard risk (fire, explosion, traffic accident, ship or submarine collision). Also, the influence of hazard risk indexes on SFT was evaluated in tunnel tube, supporting system, ventilation tower, foundation, and connection part. As the hazard risk level of SFT is compared with those of bridge, underwater tunnel, and immersed tunnel, the intrinsic risk level of SFT was evaluated. Tsunami and earthquake had higher risk level in natural hazard risk, and the risk levels of fire and explosion were higher in human factor hazard risk. Hazard risk level of SFT was 1.4 times higher than immersed tunnel, and 3.2 times higher than bridge.

Seismic Performance of Built-up Concrete Filled Square Composite Column-to beam Connection with Through Diaphragm (관통형 다이아프램을 갖는 조립형 콘크리트 충전 각형 합성기둥-보 접합부의 내진성능)

  • Kim, Sun Hee;Yom, Kyong Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • Concrete filled tubular columns are widely used because the mutual reaction between the concrete and the tube improves strength and ductility of the columns. In an attempt to secure efficient use of members, built-up square columns featuring large width-thickness ratio and the use of thin steel plates are suggested in this study. In order to evaluate the structural characteristics and seismic performance of the column-to-beam connections of the new shape columns, cyclic load test of T-shaped column-to-beam connections was conducted with variables of diaphragms and concrete-filling. Moment-rotational angle relationship, dissipated energy and failure behavior were compared to evaluate stress transfer mechanism of the new shape built-up square column-to-beam connections associated with the variables.

Evaluation of Structural Performance of Precast Modular Pier Cap (프리캐스트 모듈러 피어캡의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 2015
  • Prefabrication technologies are making bridge construction safer and less disruptive to the environment and traveling public, making bridge designs more constructible and, improving the quality and durability by shifting site work to a more controllable environment. Modular bridge substructures with concrete-filled steel tube (CFT) piers and composite pier caps were suggested to realize accelerated bridge construction. The precast segmental pier cap consists of a composite pier table and precast prestressed segments on the table. The pier table has embedded steel section to mitigate stress concentration at the connection by small tubes. Each bridge pier has four or six CFT columns which connect to the pier cap. Shear strength of the pier cap was obtained by extending vertical reinforcing bars from the table to the precast segment. Transverse prestressing was introduced to control tensile stresses by service loadings. Structural performance of the proposed modular system was evaluated by static tests. Design requirements of the composite pier cap were satisfied by continuous reinforcing bars and prestressing tendons. Standardized modular substructures can be effectively utilized for the fast replacement or construction of bridges.

Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth (식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

Analysis of Density Wave Oscillation in Boiler Furnace Wall Tubes with Parallel Channel Modeling (평행관 모델링을 통한 보일러 화로벽관 내 밀도파 불안정의 해석)

  • Kim, Jinil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • A numerical model was developed to predict the density wave oscillation (DWO) in the furnace wall tubes of a fossil-fired once-through boiler. The transient flow fields in the tubes were obtained using a 1D finite volume method in the time domain. A header model was also implemented to simulate the parallel tube connection of the wall tubes. The inlet and outlet mass flow variation in one of the parallel tubes was examined after a heat perturbation to find the DWO. After successful verification with experimental results reported in literature, the developed model was applied to the wall tubes of a 700-MW boiler furnace. In contrast to the simulation of Takitani's experiment, in which the unstable power thresholds tended to rise in the reduced bypass channel flow, no remarkable changes were observed in the power thresholds in the parallel channel modeling of the wall tubes of the boiler furnace.

A Study on Detection of a Critical Spot and the Securing Safety Method of CFRP Bicycle Forks by Finite Element Method (유한요소법을 이용한 CFRP 자전거 포크의 취약부 탐색 및 안전성 확보 방안 연구)

  • Lee, Su-Yeong;Lee, Nam Ju;Choi, Ung-Jae;Kim, Hong Seok;Shin, Ki-Hoon;Cheong, Seong-Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.1-5
    • /
    • 2016
  • A bicycle is one of the most popular sporting goods in view of a sport activity and a human health. Metallic materials such as steel, aluminum, etc. were mainly used to the bicycle fork in the past. Nowadays, the carbon fiber reinforced composite materials are widely used to the manufacturing of a bicycle fork to reduce the weight and to increase the efficiency. Safety is a most important design parameter of a bicycle fork even if the weight and cost reduction are important. Bicycle failure may happen at the critical spot of a bicycle fork and cause the accident. In this paper, the composite bicycle fork will be analyzed to secure the safety and detect a critical spot by using the finite element method with Tsai-Wu failure criterion. The stress data were obtained for the laminated composites with various number of plies and fiber orientation under the bending load. Thus, design concept of a bicycle fork was proposed to secure the safety of a bicycle. The finite element analysis results show that the connection area between a steer tube and a fork blade is critical spot, and 75 or more layers of 0 degree are needed to secure the safety of a bicycle fork.