• 제목/요약/키워드: Tube conductivity

검색결과 161건 처리시간 0.032초

튜브의 열전도도와 튜브 외면에서의 대류열전달이 보텍스튜브의 에너지 분리에 미치는 영향 (The Effect of the Thermal Conductivity of a Tube and the Convective Heat Transfer on the Outer Surface of a Tube on the Energy Separation in Vortex Tubes)

  • 유갑중;이병화;최병철
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.845-852
    • /
    • 2001
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the effects of the conductivity of a tube and convective heat transfer on the outer surface of a tube. The experiment was carried out with different conductivity (pyrex, stainless steel and copper) of a tube and three kinds of convective heat transfer modes (adiabatic condition, natural convection (air) and forced convection (water) on the outer surface of a tube. the results were obtained that hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the forced convection of water. However, the cold exit temperature was little affected by heat transfer modes on the outer surface in vortex tubes.

  • PDF

Effects of Tube Materials and Cooling Media on the Energy Separation in Vortex Tubes

  • Riu, Kap-Jong;Kim, Hyun-Woo;Park, In-Su;Kim, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.138-146
    • /
    • 2002
  • The phenomena of energy separation in vortex tubes was investigated experimentally to see the subsidiary effect of the conductivity of tube material and cooling conditions around the outer surface of the tube. The experiment was carried out with pyrex, stainless steel and copper tubes, and the heat transfer conditions of the tubes were with insulation, without in-sulation and water cooling modes respectively The results were obtained that the hot exit fluid temperature was highly affected by a change of conductivity of a tube when the outer surface was cooled by the water, while the working fluid through the tubes was air. How-ever, the cold exit temperature was little affected by the heat transfer modes on the outer surface of the vortex tube.

Effect of open-core screw dislocation on axial conductivity in semiconductor crystals

  • Taira, Hisao;Sato, Motohiro
    • Advances in nano research
    • /
    • 제1권3호
    • /
    • pp.171-182
    • /
    • 2013
  • The alternating current (AC) conductivity in semiconductor crystals with an open-core screw dislocation is studied in the current work. The screw dislocation in crystalline media results in an effective potential field which affects the electronic transport properties of the system. Therefore, from a technological view point, it is interesting to investigate properties of AC conductivity at frequencies of a few terahertz. To quantify the screw-induced potential effect, we calculated the AC conductivity of dislocated crystals using the Kubo formula. The conductivity showed peaks within the terahertz frequency region, where the amplitude of the AC conductivity was large enough to be measured in experiments. The measurable conductivity peaks did not arise in dislocation-free crystals threaded by a magnetic flux tube. These results imply different conductivity mechanisms in crystals with a screw dislocation than those threaded by a magnetic flux tube, despite the apparent similarity in their electronic eigenstates.

Hollow Cathode Discharge Tube에서의 광검류 신호 측정 (Measurement of Optogalvanic Signal in Hollow Cathode Discharge Tube)

  • 이준회;윤만영;김송강
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.874-877
    • /
    • 2002
  • The optogalvanic signals were measured using hollow cathode discharge tube with argon as buffer gas at change of discharge currents. A change of ionization rate due to electron collision causes an increase or decrease of the electric conductivity. This change in electric conductivity generates the optogalvanic signal. We conclude that optogalvanic signal has close relation with the lowest metastable atoms density at low current.

  • PDF

단일(單一) 긴 수직평판(垂直平板)핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流) (Conjugate Heat Transfer by Natural Convection from a Horizontal Heat Exchanger Tube with a Long Vertical Longitudinal Plate Fin)

  • 배대석;권순석
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.64-72
    • /
    • 1989
  • Laminar natural convection heat transfer from a horizontal heat exchanger tube with one infinitely long vertical plate fin has been studied by a finite-difference numerical procedure. In predicting convective heat transfer from a circular tube, the thermal boundary condition at solid fluid interface is usually assumed to be isothermal. However, in reality, the thermal boundary condition is not isothermal, and the tube has the thickness and the conductivity. So the temperature at the interface is not known a priori to the calculation. This problem has the conjugate phenomena which occur between the tube conduction and external natural convection, and between the fin conduction and external natural convection. Numerical results are obtained to determine the effects of the conductivity of solid wall and the thickness of tube wall on heat transfer. It is found that the conduction causes significant influence on the natural convection heat transfer at low K and high ${\delta}$.

  • PDF

핵비등 촉진 전열면 증발부를 이용한 고성능 Bubble Jet Loop Heat Pipe 개발 (Development of a High Performance Bubble Jet Loop Heat Pipe Using the Enhanced Nucleate Boiling Surface in Evaporating Section)

  • 김종수;신종석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.363-367
    • /
    • 2015
  • 본 연구는, 증발부에 핵비등 전열 촉진면을 사용하여 수평상태에서도 작동 가능한 고성능 버블젯 루프 히트파이프(BJLHP)의 개발에 관한 것이다. 비등 촉진 전열면은 소결관과 GEWA-T 전열관을 사용하였으며, 평활관을 사용한 BJLHP와 유효열전도도를 사용하여 열성능을 비교, 검토하였다. 작동유체로는 R-141b를 사용하였으며, 충전량은 BJLHP 내부 체적의 50%, 입열량은 75W와 100W로 하였다. 그 결과 소결관을 사용한 BJLHP의 열성능이 가장 우수한 것으로 나타났으며, 소결관을 사용한 BJLHP의 유효열전도도가 평활관 BJLHP보다 300% 이상 향상되었다.

전산해석을 이용한 착상이 핀튜브 열교환기 성능에 미치는 영향에 관한 연구 (A study on the performance of the finned tube heat exchanger affected by the frosting using CFD tool)

  • 김성줄;최호진;하만영;방선욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2738-2743
    • /
    • 2008
  • We conducted a study by computational simulation about the effects of frost thickness on the pressure drop and heat transfer characteristics as whole heat exchanger configuration changes. In order to perform the analysis for validation, we assumed that frost properties have constant values and the frost layers that are formed on the fin and tube surfaces are uniform. In order to find the constant thermal conductivity of frost layer, a variety of frost thermal conductivities are performed in our work and compared with the results by Lee et al. [4] and Yang et al. [5] proposed many experimental data about the 2-rows and 2-columns finned tube heat exchanger. The numerical results agreed well with the experimental data when frost conductivity is 0.07W/mK. After the validation had performed, we applied this procedure to the finned tube heat exchanger of domestic refrigeration and investigated the thermo-hydraulic characteristic of the heat exchanger affected by frost thickness according to the inlet velocities and temperatures of air considering the configuration change such as fin pitch.

  • PDF

1차원 모델에 의한 지중열교환기의 열거동 해석 (A Study on the Thermal Behavior of Vertical Borehole Heat Exchanger with 1-Dimensional Model)

  • 이세균;김대기;우정선;박상일
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.97-104
    • /
    • 2005
  • A one-dimensional heat transfer model for the vertical borehole system is derived in this study to predict the thermal behavior of the system and surrounding soil. In this model the U-tube is replaced with one effective tube of effective diameter which is surrounded by concentric grout region. All thermal resistances of borehole are counted in the grout region with effective thermal conductivity of grout. Effective thermal conductivity of grout and sand are calculated through parameter estimation. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with experimental data.

Hollow cathode discharge tube에서의 광검류 신호 측정 (Measurement of Optogalvanic Signal in Hollow Cathode Discharge Tube)

  • 이준회;정기주
    • 한국진공학회지
    • /
    • 제11권2호
    • /
    • pp.119-126
    • /
    • 2002
  • Hollow cathode discharge(HCD)에서 알곤 기체를 완충 기체로 사용하여 전류 변화에 따른 광검류 신호를 측정하였다. 광검류 신호는 방전의 전기 전도도의 증가 또는 감소에 의해 나타나며 전기 전도도의 변화는 전자 충돌에 의한 이온화율의 변화에 의해 일어난다. 낮은 방전 전류에서 광검류 신호는 가장 낮은 준안정 준위 원자의 밀도 변화와 밀접한 관계가 있다는 결론을 얻었다.

월동시 양식장의 연료 절감 대책 (A study on the reduction of fuel consumption for fish farm during winter season)

  • 박종운;한규일
    • 수산해양교육연구
    • /
    • 제7권1호
    • /
    • pp.31-43
    • /
    • 1995
  • For the fuel saving in the fish farm, the heat transfer performances of various tubes, XL-tube, copper-tube, copper-Nikel-tube and Al-brass-tube, were compared. The XL-tube, which is most commonly used for heating water, showed the poorest heater transfer performance, while the Al-Brass tube shows the best performance. As far as average temperature difference of four tubes concerns, XL-tube is $3.34^{\circ}C$, Copper tube is $10.34^{\circ}C$, Copper-Nikel tube is $11.3^{\circ}C$, Al-Brass-tube is $12^{\circ}C$, The best heat transfer performance of Al-Brass tube results from the enhancement of heat transfer coefficient caused by fin effect and good conductivity of the material.

  • PDF