• Title/Summary/Keyword: Tube array

Search Result 142, Processing Time 0.022 seconds

Development of the active magnetic regenerative refrigerator for room temperature application (상온 능동형 자기 재생 냉동기의 개발)

  • Park, I.;Kim, Y.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

Heat Transfer and Pressure Drop Characteristics of Heat Exchanger for a Gas-insulated Transformer (가스절연 변압기용 열교환기의 열전달 및 압력손실 특성 연구)

  • Ham, Jin-Ki;Lee, Joon-Yeob;Kim, Young-Ki;Song, Seok-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1046-1051
    • /
    • 2004
  • A plate-fin-tube heat exchanger used for a $SF_{6}$ gas-insulated transformer is extremely important since the dissipation of the heat generated from inside coils has a significant effect on the performance as well as the durability of the transformer. The heat exchanger consists of corrugated plate fins and staggered array tube bundles for coolant. In order to find out heat transfer and pressure drop characteristics, series of numerical analyses for plate fins with enhanced surface geometries were conducted. Based on the results of the numerical analyses, an improved model of the plate fin has been proposed.

  • PDF

Mass production of carbon nanotubes using Vapor Phase Growth (기상합성법을 이용한 탄소나노튜브의 대량합성)

  • 류승철;이태재;이철진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.123-126
    • /
    • 2001
  • Multiwalled carbon nanotubes were massively produced by the catalytic reaction of C$_2$H$_2$ - Fe(CO)$\sub$5/ mixture at 750 - 950$^{\circ}C$ in a quartz tube reactor and over quartz substrates. Well-aligned MWNT array grows perpendicular to the quartz tube reactor and the quartz substrates at an average of 60 nm in diameter and up to several thousands of micrometers in length. This method does not require any pretreatment of substrates and CNTs are grown at atmospheric pressure. It could be suitable for mass production of multiwalled nanotubes. Scanning electron microscope and transmission electron microscope images of the nanotubes deposited on the substrates allowed us to monitor the quality of MWNTs grown under different operating conditions.

  • PDF

Micro Pattern Forming on Polymeric Circular Tubes by Hydrostatic Pressing (폴리머 원형 튜브 대상 미세 패턴 정수압 성형)

  • Rhim, S.H.
    • Transactions of Materials Processing
    • /
    • v.23 no.8
    • /
    • pp.507-512
    • /
    • 2014
  • The objective of the current investigation is to establish techniques in micro pattern forming operations of polymeric circular tubes by using hydrostatic pressing. This method was developed and successfully applied to the micro pattern forming on polymeric plates. The key idea of the new technique is to pressurize multiple vacuum-packed substrate-mold stacks above the glass transition temperature of the polymeric substrates. The new process is thought to be a promising micro-pattern fabrication technique for two reasons; first, (hydro-) isostatic pressing ensures a uniform micro-pattern replicating condition regardless of the substrate area and thickness. Second, multiple curved substrates can be patterned at the same time. With the prototype forming machine for the new process, micro prismatic array patterns, 25um in height and 90 degrees in apex angle, were successfully made on the PMMA circular tubes with diameters of 5~40mm. These results show that this process can be also used in the micro pattern forming process on curved plates such as circular tube.

Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump (흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션)

  • 박윤철;민만기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

Study on Extraction of the Center Point of Steam Generator Tubes (증기발생기 세관의 중심좌표추출에 대한 연구)

  • 조재완;김창회;서용칠;최영수;김승호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.263-266
    • /
    • 2002
  • This paper describes extraction procedure for the center coordinates of steam generator tubes of Youngkwang NPP #6, which are arrayed in triangular patterns. Steam generator tube images taken with wide field-of-view lens and low-light lamp mounted on a ccd camera tend to have low contrast, because steam generator is sealed and poorly illuminated. The extraction procedures consists of two steps. The first step is to process the region with superior contrast in entire image of steam generator tubes and to extract the center points. Using the extracted coordinates in the first step and the geometrical array characteristics of tubes lined up in regular triangle forms, the central points of the rest region with low contrast are estimated. The straight lines from center point of a tube to neighbour points in horizontal and 60, 120$^{\circ}$ degree directions are derived. The intersections of straight line In horizontal direction and slant line in regular triangle direction are selected as the center coordinates of steam generator tubes. The Chi-square interpolation method is used to determine the line's coefficients in horizontal and regular triangle direction.

  • PDF

A Study on the Characteristics of Pressure Distribution for Heat Exchanger Types of Domestic Gas Boiler (가정용 가스보일러 열교환기 유형에 따른 압력분포특성에 관한 연구)

  • 최경석;오율권;차경옥
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.22-28
    • /
    • 2001
  • Heat transfer and pressure distribution for heat exchanger type of domestic gas boiler are different from shape, pitch, thickness of fin and array of pipe respectively. In order to measure the pressure distribution across the heat exchanger, a suction type wind tunnel was constructed and velocity distribution was measured for pilot tube(4 point) of rack type. The experiments were performed for 5 different air flow mass, rpm=3,6,9,12,15 and transverse axis of heat exchanger(x-length) is 5cm respectively. Results showed that above 9.5m/s, pressure distribution dispersion for wet type of heat exchanger is on the increase and above 5.5m/s, pressure distribution dispersion for dry type of heat exchanger is on the increase. Also, pressure distribution dispersion by comparing two different types heat exchanger, dry type of heat exchanger showed a higher augmentation than wet type of heat exchanger.

  • PDF

Effect of domain size on flow characteristics in simulating periodic obstacle flow (주기적인 경계조건을 사용하는 수치모사에서 계산영역 크기의 영향)

  • Choi, Choon-Bum;Jang, Yong-Jun;Han, Seok Youn;Kim, Jin-Ho;Yang, Kyung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2477-2482
    • /
    • 2008
  • Effect of computational domain size in simulating of periodic obstacle flow has been investigated for the flow past tube banks. Reynolds number, defined by freestream velocity (U) and cylinder diameter (d), was fixed as 200, and center-to-center distance (P) as 1.5d. In-line square array was considered. Drag coefficient, lift coefficient and Strouhal number were calculated depending on domain size. Circular cylinders were implemented on a Cartesian grid system by using an immersed boundary method. Boundary condition is periodic in both streamwise and lateral directions. Previous studies in literature often use a square domain with a side length of P, which contains only one cylinder. However, this study reveals that size is improper. Especially, RMS values of flow-induced forces are most sensitive to the domain size.

  • PDF

A Pulse Power Supply for a Metal Vapor Laser Using IGBTs (IGBT를 사용한 금속증기레이저용 펄스 전원)

  • 진정태;차병헌;김철중;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.415-419
    • /
    • 2004
  • A pulse power supply using IGBTs and MPC (magnetic pulse compression) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a vacuum tube or thyratron type pulse power supply. A series-connected IGBT array generated a long pulse of its pulse width 2 ${\mu}\textrm{s}$ md then it was compressed to less than 100 ns by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 10 mm inner diameter and 0.5 m discharge length. and successfully operated.

Numerical Analysis of ECT for Investigation of SG Tube in NPP (원전 증기발생기세관 진단을 위한 와전류탐상 수치해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.509-512
    • /
    • 2008
  • 본 논문에서는 원전 증기발생기세관 진단을 위한 와전류탐상의 전자기 수치해석을 수행하였다. 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 3차원 전자기 유한요소 프로그램인 OPERA 3D를 이용하여 전자기 수치 해석을 수행하였다. 신호해석을 위해 사용된 프로브의 종류는 배열와전류프로브이며, FBH 결함의 신호를 해석하였다. 결함의 깊이는 세관 두께의 40[%], 60[%] 및 100[%]로 하였다. 시험주파수는 100[kHz], 300[kHz], 400[kHz]를 사용하였고, 각각의 결함 및 시험주파수에 대한 결과를 비교 분석하였다. 본 논문의 결과는 앞으로 배열와전류프로브를 이용하여 원전 증기발생기세관 진단을 할 경우 신호 해석에 도움이 될 것으로 사료된다.

  • PDF