Tubular Web Reduced Beam Section (TW-RBS) connection, a numerical and experimental study and result comparison

  • Zahrai, Seyed M.;Mirghaderi, Seyed R.;Saleh, Aboozar
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.571-583
    • /
    • 2017
  • A kind of accordion-web RBS connection, "Tubular Web RBS (TW-RBS)" connection is proposed in this research. TW-RBS is made by replacing a part of web with a tube at the desirable location of the beam plastic hinge. This paper presents first a numerical study under cyclic load using ABAQUS finite element software. A test specimen is used for calibration and comparison of numerical results. Obtained results indicated that TW-RBS would reduce contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Furthermore, the tubular web like corrugated sheet can improve both the out-of-plane stiffness of the beam longitudinal axis and the flange stability condition due to the smaller width to thickness ratio of the beam flange in the plastic hinge region. Thus, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam as just local buckling of the beam flange at the center of the reduced section was observed during the tests. Also change of direction of strain in arc shape of the tubular web section is smaller than the accordion webs with sharp corners therefore the tubular web provides a better condition in terms of low-cycle fatigue than other accordion web with sharp corners.

공명흡음에 의한 목재와 목질보드의 흡음성능개선 (Improvement of Sound Absorption Capability of Wood and wood-based Board by Resonant Absorption)

  • 강춘원;박희준
    • Journal of the Korean Wood Science and Technology
    • /
    • 제29권1호
    • /
    • pp.16-21
    • /
    • 2001
  • 공명흡음에 의해 목재와 목질보드의 흡음성능을 개선하고자 무천공, 단순천공 그리고 계단형으로 천공한 목재와 목질보드의 흡음률을 정재파비를 이용하는 관내법으로 조사하였다. 그 결과 측정주파수범위에서 계단형으로 천공한 시험편이 보통의 시험편보다 높은 흡음률을 나타내었으며, 특히 3~4KHz의 주파수영역에서는 50~60% 정도 높은 흡음률을 나타내었다. 목질보드는 측정주파수범위에서 높은 흡음률을 나타내었으며 천공한 목질보드는 300Hz에서 500Hz의 주파수 영역에서 조금 더 높은 흡음률을 나타내었다. 이는 시험편에 조성한 계단형 천공이 단일공명기로 작용하여 특정주파수영역에서 흡음률이 증가된 것으로 사료된다. 몇 가지 크기의 공극에 의해 공명이 발생하는 예상주파수는 실측한 주파수-흡음률 곡선에서 외삽한 공명주파수와 잘 일치하였다.

  • PDF

불산 식각 농도 및 시간이 lithium disilicate 도재와 레진시멘트의 전단결합강도에 미치는 영향 (EFFECTS OF HYDROFLUORIC ACID CONCENTRATION & ETCHING TIME ON THE SHEAR BOND STRENGTH BETWEEN LITHIUM DISILICATE CERAMIC AND RESIN CEMENT)

  • 서재민;박찬운;안승근
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.407-418
    • /
    • 2007
  • Purpose: The objective of this study was to evaluate the effects of hydrofluoric acid concentration & etching time on the shear bond strength between IPS Empress 2 ceramic and resin cement. Material and methods: Thirty three rectangular shape ceramic specimens($20{\times}12{\times}5mm$ size, IPS Empress 2 core materials) were used for this study. The ceramic specimens divided into ten experimental groups with three specimens in each group and were etched with hydrofluoric acid(4%, 9%) according to different etching times(30s, 60s, 90s, 120s, 180s). Etched surfaces of ceramic specimens were bonded with resin cement(Rely X Unicorn) using acrylic glass tube. All cemented specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed of 0.5mm/min and the maximum load at fracture(kg) was recorded. Collected shear bond strength data were analyzed with one way ANOVA and Duncan tests. All etched ceramic surfaces were examined morphologically using SEM(scanning electron microscopy). Results: Shear bond strength of etching group$(35.89{\sim}68.01MPa)$ had four to seven times greater than no-etching group$(9.53{\pm}2.29MPa)$. The ceramic specimen etched with 4% hydrofluoric acid for 60s showed the maximum shear bond strength$(68.01{\pm}11.78MPa)$. Ceramic surface etched with 4% hydrofluoric acid for 60s showed most retentive surface texture. Conclusion: It is considered that 60s etching with 4% hydrofluoric acid is optimal etching methods for IPS Empress 2 ceramic bonding.

비선형 매개변수 추정법을 이용한 열확산계수의 측정 (The estimation of thermal diffusivity using NPE method)

  • 임동주;배신철
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1679-1688
    • /
    • 1990
  • 본 연구에서는 역산법으로 열확산계수를 추정하기 위하여 비선형 매개변수 추 정법을 사용하며, 실험데이터의 통계적 처리방법, 추정이론을 정리하여 이 추정법에 적합한 알고리즘을 만들었다. 수정된 Gauss법을 컴퓨터에 사용할 수 있도록 프로그 램을 개발하였으며, 이 방법의 정확성을 증명하기 위하여 일정열유법과 동일한 실험장 치를 사용하되 경계조건이나 초기조건을 시간의 변화에 따라 이산적으로 측정하여, 매 개변수인 열확산계수를 온도의 함수로 찾고자 하였으며, 통계적인 개념보다는 역산적 인 면에 더 치중하였다.

생체의학 임플란트재료로서 Ti-Nb계 합금의 조직과 기계적 성질에 미치는 HEMM의 영향 (The Effect of HEMM on Microstructure and Mechanical Properties of Ti-Nb Alloy for Implant Biomedical Materials)

  • 우기도;최갑송;이현범;김인용
    • 한국재료학회지
    • /
    • 제17권11호
    • /
    • pp.587-592
    • /
    • 2007
  • Al-42wt%Nb powder was prepared by high-energy mechanical milling(HEMM). The particle size, phase transformation and microstructure of the as-milled powder were investigated by particle size distribution (PSD) analyzer, scanning electron microscopy (SEM), X-ray diffractometery (XRD), transmission electron microscopy (TEM)and differential thermal analysis (DTA). The milled powders were heated to a sintering temperature at 1000C with under vaccum with vaccum tube furnace. Microstructural examination of sintered Ti-42wt%Nb alloy using 4h-milled powder showed Ti-rich phases (${\alpha}$-Ti) which are fine and homogeneously distributed in the matrix (Nb-rich phase: ${\beta}$-Ti). The sintered Ti-42wt%Nb alloy with milled powder showed higher hardness. The microstructure of the as quenched specimens fabricated by sintering using mixed and milled powder almost are same, but the hardness of as quenched specimen fabricated by using mixed powder increased due to solution hardening of Nb in Ti matrix. The aging effect of these specimens on microstructural change and hardening is not prominent.

광중합(光重合) 레진의 경도측정(硬度測定)에 관(關)한 연구(硏究) (A STUDY ON THE HARDNESS IN VISIBLE LIGHT COMPOSITE RESIN)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.179-188
    • /
    • 1989
  • The purpose of this study was to measure Micro vicker's hardness of 4 kinds of anterior Composite resins (Pyrofil light bond anterior, Lite-fil anterior, Photo clear fil anterior, Silux) and 6 kinds of posterior Composite resin (Pyrofil light bond posterior. Lite-fil posterior, Photo clear fil posterior, Occlusin posterior, Palfique light posterior, P-30, posterior) according to deference of depth and distance of light tip from surface of composite resin. Each composite resin was filled into Teflon tube of 5mm in diameter and 5mm in depth, celluloid matrix was covered and the light in accordance with each composite resin was irradiated in distance of zero millimeter and 1 cm from light tip to surface of composite resin for 30 seconds. Specimens were sectioned longitudinally with cutting device. Microvicker's hardness measurements ware made at the depth of surface, 1mm, 2mm, 3mm, 4mm and 5mm from the surface to deep portion. Vicker's hardness numbers were taken on each depth under 200gm load for 30 seconds with MVK-E. The following results were: 1. The highest hardness value was measured at 1 mm depth. Then the deeper the depth, the lesser the hardness was observed. 2. The hardness value of anterior composite resins is lower than one of posterior composite resins. 3. Hardness number of composite resin irradiated in distance of zero millimeter from surface of composite resin was higher than one of 1 cm from surface of composite resin. 4. The pattern of hardness change at varying depth was similar to all the experimental material with no relation to distance of light from specimen.

  • PDF

Sp-Creep 시험에 의한 고온 크리프 특성 평가 기술 개발(ll) - 보일러 헤더 - (Development of Evaluation Technique of High Temperature Creep Characteristics by Small Punch-Creep Test Method (ll) - Boiler Header -)

  • 백승세;이동환;하정수;유효선
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.55-60
    • /
    • 2002
  • For the development of a new creep test technique, the availability of SP-Creep test is discussed for 1Cr-0.5Mo boiler header material. And some results are also compared with those of 2.25Cr- 1Mo steel which widely uses as boiler superheater tube. The results can be summarized as follows. The load exponents(n) obtained by SP-Creep test for 1Cr-0.5Mo steel are decreased with increasing creep temperature and the values are 15.67, 13.89, and 17.13 at 550$^{circ}C$ ,575$^{circ}C$ and 600$^{circ}C$, respectively. The temperature dependence of the load exponent is given by n = 107.19 - 0.1108T. This reason that load exponents show the extensive range of 10∼16 is attributed to the fine carbide such as M$_{23}$C$_{6}$ in lath tempered martensitic structures. At the same creep condition, the secondary creep rate of 1Cr-0.5Mo steel is lower than the 2.25Cr-1Mo steel1 due to the strengthening microstructure composed by normalizing and tempering treatments. Through a SEM observation, it can be summarized that the primary, secondary, and tertiary creep regions of SP-Creep specimen are corresponding to plastic bending, plastic membrane stretching, and plastic instability regions among the deformation behavior of four steps in SP test, respectively.y.

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

표면처리에 따른 상아질과 콤포짓드 레진간의 전단결합강도에 관한 연구 (A STUDY ON SHEAR BOND STRENGTH OF COMPOSITE RESIN TO DENTIN FOLLOWING SURFACE TREATMENTS)

  • 노은희;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.200-208
    • /
    • 1991
  • The purpose of this study was to observe shear bond strength of composite resin to dentin following surface treatment. Freshly extracted forty-eight sound human molars were used in this study. They were stored at $4^{\circ}C$ physiologic saline solution before experiment. The teeth was then mounted with self curing acrylic resin in brass mold. The buccal surfaces of the teeth were grinding approximately 1.5mm by means of water-irrigated grinding wheel to expose the flattened fresh dentin surfaces. The specimens were divided into 6 groups according to preparation and treatment procedures on dentin surfaces; Group 1: Untreated after preparation with No.301 diamond point Group 2: Treated with primer for 60 seconds after preparation with No.301 diamond point Group 3: Untreated after preparation with No.700 fissure carbide bur Group 4: Treated with primer for 60 seconds after preparation with No.700 fissure carbide bur Group 5: Untreated after grinding with 600 grit silicon carbide paper Group 6: Treated with primer for 60 seconds after grinding with 600 grit silicon carbide paper Light cure dental adhesive was applicated to each specimen. Silux plus(3M) was inserted then into polyethylene tube of 3mm diameter and 3mm height, and polymerized to dentin surface. All of the specimens were stored in distilled water at $35.6^{\circ}C$ for 24 hours prior to testing. The shear bond strength was measured using an Instron Universal Testing Machine. The results obtained from this study were as follows: 1. The shear bond strength to dentin was the highest in group II. 2. The shear bond strength to dentin was the lowest in group III. 3. There was no significant difference in shear bond strength to dentin according to preparation instrument. 4. The primer treatment group showed significantly greater shear bond strength than untreated group.

  • PDF

중환자실 뇌혈관질환자에게 수행된 간호중재분석 (A study of the Nursing Interventions performed by the ICU nurses to the patients with Cerebrovascular disorders)

  • 박영례;최경숙
    • 재활간호학회지
    • /
    • 제4권1호
    • /
    • pp.94-104
    • /
    • 2001
  • The purpose of this study was to analysis of nursing interventions performed by the ICU nurses to the patients with cerebrovascular disorder practically from one university hospital in Seoul. The data were collected from 15 nurses with 86 cerebrovascular disorder cases from one ICU with the questionaire to write frequency of nursing care done by the surveyee from May, 2, 2000 to July, 3, 2000 and the list of 66 nursing interventions selected out of 433 NIC(Nursing Interventions Classification) of Iowa University which were translated into Korean (44 items) and core nursing interventions by ICU nurses (22 items; KIm, Su-Jin, 1997). The data were analysed with SPSS program. The results are as follow : 1. The most frequently used nursing interventions were vital sign monitoring, fall prevention, cerebral edema management, dysreflexia management, neurologic monitoring, cardiac care, communication enhancement, technology management, bed rest care, respiratory monitoring in rank. 2. The most frequently used nursing intervention domains were 'Physiological : Complex', 'Physiological : basic', 'Behavior', 'Safty', 'Health system' in rank. In the domain of physiological : basic, the most frequently used nursing interventions were bed rest care, urinary elimination management, tube care : urinary, physical restraints in rank. In the domain of physiological : complex, the most frequently used nursing interventions were cerebral edema management, dysreflexia management, neurologic monitoring, cardiac care in rank. In the domain of behavior, the most frequently used nursing interventions were communication enhancement, touch, active listening in rank. In the domain of safty, the most frequently used nursing interventions were vital sign monitoring, fall prevention in rank. In the domain of health system, the most frequently used nursing interventions were technology management, specimen management in rank. 3. some difference of the frequency practicing the nursing interventions according to the shift of duties was found. For example, medication administration was common at day duty, touch was practiced at evening duty, temperature regulation was performed.

  • PDF