Sizing of a tube inlet orifice of a once-through steam generator to suppress the parallel channel instability

  • Yoon, Juhyeon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3643-3652
    • /
    • 2021
  • Sizing the tube inlet orifice of a Once-Through Steam Generator (OTSG) is important to protect the integrity of the tubes from thermal cycling and vibration wear. In this study, a new sizing criterion is proposed for the tube inlet orifice to suppress the parallel channel instability in an OTSG. A perturbation method is used to capture the essential parts of the thermal-hydraulic phenomena of the parallel channel instability. The perturbation model of the heat transfer regime boundaries is identified as a missing part in existing models for sizing the OTSG tube inlet orifice. Limitations and deficiency of the existing models are identified and the reasons for the limitations are explained. The newly proposed model can be utilized to size the tube inlet orifice to suppress the parallel channel instability without excessive engineering margin.

X-ray Micro-Imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-Bubbles (X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시 측정기술 개발)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.659-664
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of 20∼60$\mu\textrm{m}$ diameter moving upward in an opaque tube (${\Phi}$=2.7mm) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

Synchrotron X-ray Micro-imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-bubbles (X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시측정)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1744-1748
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}=2.7mm$) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

  • PDF

Study of different flexible aeration tube diffusers: Characterization and oxygen transfer performance

  • Hongprasith, Narapong;Dolkittikul, Natchanok;Apiboonsuwan, Kamolnapach;Pungrasmi, Wiboonluk;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.233-240
    • /
    • 2016
  • The research aims to study the different flexible rubber tube diffusers used in urban wastewater treatment processes and aquaculture systems. The experiment was conducted in small-scale aeration tank with different physical properties of the tubes that were used as aerators. The volumetric mass transfer coefficient ($k_La$), oxygen transfer efficiency (OTE) and aeration efficiency (AE) were measured and determined to compare the diffusers. Moreover, the bubble hydrodynamic parameters were analyzed in terms of bubble diameter ($d_B$) and rising velocity ($U_B$) by a high speed camera (2,000 frames/s). Then the interfacial area (a) and liquid-side mass transfer coefficient ($k_L$) can be calculated. The physical properties (tube wall thickness, tensile strength, orifice size, hardness and elongation) have been proven to be the key factor that controls the performance (kLa and OTE). The effects of hardness and elongation on bubble formation, orifice size and a-area were clearly proved. It is not necessary to generate too much fine bubbles to increase the a-area: this relates to high power consumption and the decrease of the kL. Finally, the wall thickness, elongation and hardness associated of the flexible tube diffuser (tube No. 12) were concluded, to be the suitable properties for practically producing, in this research.

The Effects of viscosity and Osmolality of Enteral Solution on Flow Rates Through Nasogastric Tubes in Vitro (경관급식 유동액의 점도와 삼투압이 체외에서 비장관 튜브를 통한 흐름속도에 미치는 영향)

  • 한경희
    • Journal of Nutrition and Health
    • /
    • v.26 no.6
    • /
    • pp.793-803
    • /
    • 1993
  • This study was designed to measure viscosity, osmolality and in vitro flow rates via nasogastric tubes for 6 types of commercially available and 9 hospital-blenderized enteral solutions and to examine the effect of viscosity and osmolaility of enteral formula on the flow rates in gravity drip administration. Each solution was infused through 18, 16, 14, 12 French sizes of silicone rubber tube. Flow rates were measured six times at $25^{\circ}C$ using formula bags and drip sets hung at a uniform height on a intravenous drip stand with tube uniformly positioned in collecting container. Viscosity ranged widely from 16.0 to 195.5 cps with mean, 64.61$\pm$64.42 for hospital-blenderized formula while mean viscosity of commercial formula was 7.60$\pm$4.84 cps. Mean osmolality of commercial formula and hospital-blenderized formula were 370$\pm$100.80, 540.33$\pm$89.37 mOsm/kg respectively. There was negative relationship between viscosity of formula and flow rates through tubes but no significant relationship between flow rates and osmolalty. Some of hospital-blenderized formula was too viscous to be infused througth tube with gravity drip administration and the recipe of formula requires to be modiifed. On the other hand, commercial formula with the low viscosity flows too rapidly with large bore size tubes. Smaller size of tube must be selected for hyperosmolar solution to decrease possible side effects associated with tube feeding. Two kinds of regression equations for flow rates obtained according to viscosity and tube sizes were also presented for the purpose of practical uses. In conclusion, this study emphasizes that viscosity of fomula, osmolality, patient's tolerance and comfort, caloric density should be considered in the selection of tubes for gravify drip administration.

  • PDF

The Impact of Video Quality and Image Size on the Effectiveness of Online Video Advertising on YouTube

  • Moon, Jang Ho
    • International Journal of Contents
    • /
    • v.10 no.4
    • /
    • pp.23-29
    • /
    • 2014
  • Online video advertising is now an increasingly important tool for marketers to reach and connect with their consumers. The purpose of this study was to empirically investigate the impact of video format on online video advertising. More specifically, this study aimed to explore whether online video quality and image size influences viewer responses toward online video advertising. By conducting an experimental study on YouTube, the results suggested that enhanced video quality of online advertising may have an important impact on effectiveness of the advertising, and the concept of presence is a key to understanding the effects of enhanced video quality in online advertising.

Effects of Microstructure on the Fretting Wear of Inconel 690 Steam Generator Tube

  • Hong, Jin-Ki;Kim, In-Sup;Park, Chi-Yong;Kim, Jin-Weon
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.132-141
    • /
    • 2002
  • The effects of microstructure on fretting wear were investigated in Inconel 690 tube. The microstructure observation indicated that the solution annealing temperature and time affected the grain size of the Inconel 690 tubes. The carbide morphology, along grain boundaries, was mainly affected by thermal treatment time and temperature. The wear test results showed that specimens with larger grain size and with coarse carbides along grain boundaries had better wear resistance. Cracks were found in specimens with carbides along the grain boundary, while few cracks were found in carbide free specimens. It seemed that the carbides on grain boundary assisted crack formation and propagation in carbide containing specimens. On the other hand, the micro-hardness of specimen did not have a major role in fretting wear. It could be inferred from the SEM images of worn surfaces that the main wear mechanism of carbide containing specimen was delamination, while that of carbide free specimen was abrasion.

Identification of nonregular indication according to change of grain size/surface geometry in nuclear power plant (NPP) reactor vessel (RV)-upper head alloy 690 penetration

  • Kim, Kyungcho;Kim, Changkuen;Kim, Hunhee;Kim, Hak-Joon;Kim, Jin-Gyum;Jhung, Myungjo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1524-1536
    • /
    • 2017
  • During the fabrication process of reactor vessel head penetration (RVHP), the grain size of the tube material can be changed by hot or cold work and the inner side of the tube can also be shrunk due to welding outside of the tube. Several nonregular time-of-flight diffraction (TOFD) signals were found because of deformed grains. In this paper, an investigation of nonregular TOFD indications acquired from RVHP tubes using experiments and computer simulation was performed in order to identify and distinguish TOFD signals by coarse grains from those by Primary Water Stress Corrosion Crack (PWSCC). For proper understanding of the nonregular TOFD indications, microstructural analysis of the RVHP tubes and prediction of signals scattered from the grains using Finite Element Method (FEM) simulation were performed. Prediction of ultrasonic signals from the various sizes of side drilled holes to find equivalent flaws, determination of the size of the nonregular TOFD indications from the coarse grains, and experimental investigation of TOFD signals from coarse grain and shrinkage geometry to identify PWSCC signals were performed. From the computer simulation and experimental investigation results, it was possible to obtain the nonregular TOFD indications from the coarse grains in the alloy 690 penetration tube of RVHP; these nonregular indications may be classified as PWSCC. By comparing the computer simulation and experimental results, we were able to confirm a clear difference between the coarse grain signal and the PWSCC signal.

A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room (엑스선 촬영실의 공간산란선 발생 인자에 관한 연구)

  • Na, Soo-Kyung;Han, Sang-Hyo
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.393-399
    • /
    • 2009
  • In this study, we measured the dose distribution of scattered ray in X-ray radiography room using an ion chamber and examined the dependency of scattered ray content on the scattered ray source and exposure condition. To study the factors of scattered ray occurrence in the acryl phantom, we measured the change in the scatted ray content according to the X-ray tube voltage (40~140 kV) and the field size ($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$). For the $35{\times}35\;cm^2$ field size, the side-scattering rate ranged from 3.1% to 14.5%. The scattered ray contributions of the phantom, collimator, X-ray tube and wall were also measured. The scattered ray contribution of the phantom was higher than 95.4% for the entire tube voltage, and those of the collimator, X-ray tube and wall were 2.6%, 1.3% and 0.7%, respectively.

  • PDF

A Study on Bagging Neural Network for Predicting Defect Size of Steam Generator Tube in Nuclear Power Plant (원전 증기발생기 세관 결함 크기 예측을 위한 Bagging 신경회로망에 관한 연구)

  • Kim, Kyung-Jin;Jo, Nam-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.302-310
    • /
    • 2010
  • In this paper, we studied Bagging neural network for predicting defect size of steam generator(SG) tube in nuclear power plant. Bagging is a method for creating an ensemble of estimator based on bootstrap sampling. For predicting defect size of SG tube, we first generated eddy current testing signals for 4 defect patterns of SG tube with various widths and depths. Then, we constructed single neural network(SNN) and Bagging neural network(BNN) to estimate width and depth of each defect. The estimation performance of SNN and BNN were measured by means of peak error. According to our experiment result, average peak error of SNN and BNN for estimating defect depth were 0.117 and 0.089mm, respectively. Also, in the case of estimating defect width, average peak error of SNN and BNN were 0.494 and 0.306mm, respectively. This shows that the estimation performance of BNN is superior to that of SNN.