  • The fin and tube heat exchanger using a two-port tube has in air-conditioner heat exchanger because heat transfer performance. This study investigates the feasibility of a fin and tube heat exchanger using two-port copper tube by mechanical expansion. The optimum size of the tube-expanding bullet for the heat exchanger using two-port tube was through numerical calculation. The heat exchanger using a two-port tube was fabricated by mechanical expansion, and the heat exchanger performance was evaluated condensation and evaporation experiments. Compared to the heat exchanger of a conventional circular tube, the pressure drop per unit length of the heat exchanger with a two-port tube decreased. Compared to the heat exchanger using a conventional circular tube, the overall heat transfer coefficient of heat exchanger with a two-port tube increased up to 13% in the case of condensation, and up to 25% in the case of evaporation. The two-port tube heat exchanger outperforms conventional heat exchanger for air conditioner with a inner grooved circular tube.

Understanding of Laminar Burning Velocity within a Length Scale Domain (길이 스케일이 관여된 층류 화염의 연소 속도 이해)

  • Jung, Yongjin;Lee, Min Jung;Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.77-78
    • /
    • 2015
  • Laminar burning velocities have been predicted by constant volume combustion chamber, counter flow burner and others. In this study, the measured flame propagation velocities in an assembled annular stepwise diverging tube were plotted with respect to equivalence ratio, length scale, and velocity scale. Three dimensional approach to understand the flame propagation velocity including laminar burning velocity is investigated, and the surface provides the correlation among quenching distance, propagation velocity, and equivalence ratio.

  • PDF

Study on Buckling Instability of Expansion Tube using Finite Element Method (유한요소법을 이용한 팽창튜브의 좌굴불안전성에 관한 연구)

  • Choi, Won-Mok;Kwon, Tae-Su;Jung, Hyun-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • Since the kinetic energy is dissipated through plastic deformation energy generated in expanding process of the tube by a die. In order to successfully absorb the kinetic energy there should be no buckling in the expansion tube during expanding process. The buckling instability of the expansion tubes is affected by the initial boundary conditions, tube thickness and length. In this study, the effects of the tube thickness except length and initial boundary condition on the buckling instability are studied using a finite element method. In addition, Analysis procedure for nonlinear post-buckling analysis of expansion tube is established. There are three kinds of finite element analysis procedures for buckling analysis of expansion tube, quasi-static analysis, linear buckling analysis and nonlinear post-buckling analysis. The effect of the geometry imperfections defined as linear superimposition of buckling modes is considered in the nonlinear post-buckling analysis. The results of finite element analysis indicate that the buckling load increase with increase of thickness of tube and geometry imperfection. Finial buckling shapes are changed with respect to the geometry imperfection.

Shape Optimization of S-tube for Heat Exchanger Used in High Temperature Environment Using FE Analysis and DOE (유한요소법과 실험계획법을 이용한 고온 열교환기용 S-관의 형상 최적화)

  • Jeong, Ho-Seung;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.497-503
    • /
    • 2012
  • The aim of this study was to optimize S-tube shape of heat exchanger in term of reducing the size of tube bundle and improving the mechanical properties such as the thermal stress and resonance. The geometric parameters such as offset length, the straight distance between one end and other end of tube, the tube length in straight portion and fillet radius was assessed as a valid parameters. The structural analysis was performed to estimate the structural characteristics. Main effect analysis was performed to investigate the main effect for the various geometric parameters. The response surface methodology was employed to establish mathematical approximation models as a function of the geometric parameters of the S-tube. Also, The optimization was performed to optimize geometric parameters of S-tube using the regression equations and optimization tool. The optimized tube shape has been proposed. Those could be used in the heat exchanger design used in high temperature.

The study on the buckling instability of tube type crash energy absorber (튜브형 충돌에너지흡수부재의 좌굴불안전성에 대한 연구)

  • Choi, Won-Mok;Jung, Hyun-Sung;Kwon, Tae-Su
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1564-1570
    • /
    • 2007
  • There are normally two types of the energy absorbers used in the crashworthiness of trains. The first is a structure type, which mainly used in not only the primary structures of the train but also the crash energy absorbers at the accident. The second is a module type, which just absorbs the crash energy independent of the primary structures and attached to the structures of the train. The expansion and inversion tube are widely used as the module type crash energy absorbers, especially in the train. The tubes should not be buckled under the load acting on the end of the tube in longitudinal direction during absorbing the crash energy. The buckling stability of the tubes is affected by the boundary conditions, thickness and length of tube. In this study, the effects of the length and thickness of the tubes on the buckling load are studied by using the ABAQUS, a commercial finite element analysis program, and then presents the guideline to design the tube. The analysis processes to compute the buckling load consist of a linear buckling analysis and a nonlinear post-buckling analysis. The buckling modes are evaluated by the linear buckling analysis, as using these modes, the buckling loads are computed by the nonlinear post-buckling analysis.

  • PDF

Simulation of the effects of a non-adiabatic capillary tube on refrigeration cycle (비단열 모세관의 영향을 고려한 냉동 사이클 시뮬레이션)

  • Park, Sang-Goo;Son, Ki-Dong;Jeong, Ji-Hawn;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.255-262
    • /
    • 2008
  • The simulation of refrigeration cycle is important since the experimental approach is too costly and time-consuming. The present simulation focuses on the effect of capillary tube-suction line heat exchangers (CT-SLHX), which are widely used in small vapor compression refrigeration systems. The simulation of steady states is based on fundamental conservation equations of mass and energy. These equations are solved simultaneously through iterative process. The non-adiabatic capillary tube model is based on homogeneous two-phase model. This model is used to understand the refrigerant flow behavior inside the non-adiabatic capillary tubes. The simulation results show that both of the location and length of heat exchange section influence the coefficient of performance (COP). These results can be used in either design calculation of capillary tube length for refrigeration cycle or effect of suction line heat exchanging on refrigeration cycle.

  • PDF

Acoustic effects of the sound tube and resonance cavity in Korean Brahman Bells (한국범종의 음관과 명동)

  • 이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 1983
  • The presence of the sound tube and resonance cavity is unique in Korea Brahman Bells which is no examples in other country bells in the world. The sound tube erected in the crown is effective to emit the fundamental tone of the bell when the condition of resonant transmissibility is satisfied. The results of our analysis shows that the optimum length of the sound tube in the Bell Emile is 96cm but is not the present length, 77cm. The resonance cavity erected underneath the lip of the Bell Emile is found to be for the resonance of standing waves in the space including both bell cavity and resonance cavity and resonance cavity to the fundamental tone of the bell itself, in order that the strongest vibration can last long by least energy and lengthen the reverberation of the bell. Some historical remarks are also made on the magic flute, MANPASIKJUK, which was in existence in Shilla that can lull all evil waves, such as plagues, storms, droughts, famines and even enemies. The sound tube erected in the crown of the bell was originated in this magic flute. Finally, a strong proposal is advanced on the new national symbol of Korean traditional cultural assets. Indeed, it should be highly recommended that the Great King's Bell Emile would be the only real symbol of our national cultural assets by its own right of excellency and richness in every aspect of arts and sciences.

  • PDF

Flow Characteristics of a Gas-Liquid Slug Flow in Small Vertical Tubes (작은 수직관을 흐르는 기-액 슬러그 유동의 유동특성)

  • Kye, Seok-Hyun;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.246-254
    • /
    • 2013
  • Some characteristics of nitrogen-water slug flow were optically measured, in vertical acrylic tubes of 2, 5 and 8 mm diameter. Bubble velocity, bubble and unit cell lengths were measured, by analyzing the light intensity signals from two sets of dot laser-infrared sensor modules mounted along the transparent tubes. Optical images of the bubbles were also taken and analyzed, to measure bubble shapes and liquid film thickness. It was found that the measured bubble velocities were in good agreement with the empirical models in the literature, except for those measured under high superficial velocity condition in the 2 mm tube. Bubble length was found to be the longest in the 2 mm tube, being 4 to 5 times those of the other tubes. Liquid film was found to have developed early in the 2 mm tube, which made the blunt shape of the bubble head. Liquid film thickness in the 8 mm tube was measured at almost twice those of the other tubes.

Palliative Treatment with Celestin`s tube in Advanced Esophageal Cancer (진행성 식도암의 Celestin`s tube 를 이용한 고식적 치료)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.529-533
    • /
    • 1985
  • Though esophageal cancer was not a common disease, early metastasis and direct extension to adjacent organ were important on the treatment of disease. Therefore, palliative operation was often useful in advanced esophageal cancer. Between June 1985 through July 1985, we treated three cases of inoperable esophageal cancer with Celestin`s endo-esophageal tube by esophageal intubation. Three operations were done under general anesthesia. Celestin`s tube were inserted via oral cavity and additional traction on stomach were applied. After complete insertion of tube was done, the distal end of Celestin`s tube was modified in length. Also stay suture was applied between tube and stomach wall was applied. Postoperative esophagogram revealed good esophageal patency through Celestin`s tube. Clinically, swallowing difficulty was much improved after operation.

  • PDF

Evaluation on the Performance of Design Parameters in Earth Tube System (지중튜브시스템 주요 설계 변수의 성능 평가)

  • Hwang, Yong-Ho;Hwang, Seok-Ho;Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.87-94
    • /
    • 2016
  • Earth tube system can be installed in many ways. However, performance data on earth tube system is still insufficient. Therefore, in this study seven design parameters of earth tube systems were chosen such as underground earth tube length, depth, tube thermal conductivity, thickness, radius, soil conditions, and fan type. And the change effects in the values of the seven parameters on earth tube exit temperatures and heat transfer rate were examined through Energyplus simulations.