• Title/Summary/Keyword: Tube 방향

Search Result 375, Processing Time 0.028 seconds

Pressure Distribution over Tube Surfaces of Tube Bundle Subjected to Two-Phase Cross-Flow (이상 유동에 놓인 관군의 표면에 작용하는 압력 분포)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Two-phase vapor-liquid flows exist in many shell and tube heat exchangers such as condensers, evaporators, and nuclear steam generators. To understand the fluid dynamic forces acting on a structure subjected to a two-phase flow, it is essential to obtain detailed information about the characteristics of a two-phase flow. The characteristics of a two-phase flow and the flow parameters were introduced, and then, an experiment was performed to evaluate the pressure loss in the tube bundles and the fluid-dynamic force acting on the cylinder owing to the pressure distribution. A two-phase flow was pre-mixed at the entrance of the test section, and the experiments were undertaken using a normal triangular array of cylinders subjected to a two-phase cross-flow. The pressure loss along the flow direction in the tube bundles was measured to calculate the two-phase friction multiplier, and the multiplier was compared with the analytical value. Furthermore, the circular distributions of the pressure on the cylinders were measured. Based on the distribution and the fundamental theory of two-phase flow, the effects of the void fraction and mass flux per unit area on the pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure on the tube by a numerical method. It was found that for low mass fluxes, the measured two-phase friction multipliers agree well with the analytical results, and good agreement for the effect of the void fraction on the drag coefficients, as calculated by the measured pressure distributions, is shown qualitatively, as compared to the existing experimental results.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change (튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구)

  • Jeon Yong-Han;Kim Nam-Jin;Kim Chong-Bo
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.28-34
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the Hour has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mom Nusselt number of the former was greater thu that of the latter.

Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD (전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석)

  • Nam, Ki-Won;Min, Jun-Kee;Jeong, Ji-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.491-499
    • /
    • 2010
  • Heat transfer performance of tube bundles have long been investigated since they were widely used. Most of previous experimental and numerical works for tube bundles were performed with tube diameter in the range of 25~51mm and Reynolds number of $8.000{\leq}Re{\leq}30.000$. Recently, tube bundles with small diameter tube collects interests since the mini-channel tube provides higher compactness. The present work aims to investigate the applicability of previous correlations available in the open literature to the tube bundles with small diameter of 1.5mm and $3.000{\leq}Re{\leq}7.000$. A commercial CFD package was used to analyze the thermal-hydraulic performance of them. The results show that the Zukauskas correlation developed for larger diameter tube and higher Reynolds number are still in good agreement with them within the discrepancy of 4.7%. The analyses also show that the Nuselt number increases with a decrease in the longitudinal pitch.

Characteristics Improvement of Luminous-Tube Transformer using FEM (유한요소법을 이용한 네온관 전원공급용 변압기의 특성개선연구)

  • Song, Hyuk-Jin;Shin, Pan-Seok;Park, Kyu-Young
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.143-145
    • /
    • 1997
  • 특수변압기의 일종인 네온 변압기의 기본원리와 특성을 조사하고 원가절감, 효율향상등 특성개선을 위하여 누설자속의 해석기술과 규소강판의 압연방향에 따른 자속의 영향, 압연방향성 코아의 형상설계방향 등을 제시한다.

  • PDF

Hollow tube Prism (중공형 원통 프리즘)

  • Gong, Hong-Jin;Choi, Jin;Park, Young-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.124-125
    • /
    • 2003
  • 레이저 광선이 발명이 된 이래로 레이저 빔을 360도 전 방향으로 발사시키는 광학적 장치의 필요성이 매우 컸으며, 이를 이용한 응용장치가 많이 있다. 그러나, 불행히도 이제까지 레이저 빔을 360도 전 방향으로 발사시키는 광학적인 단일 요소가 개발된 적이 없었다. 이 레이저 빔을 360도 전 방향으로 발사시키는 광학적 장치는 회전거울 혹은 회전 홀로그램을 이용한 것이 고작이었다. 하지만, 이러한 회전식장치는 장치의 복잡성, 회전 모터의 회전축의 오차 등 여러 가지 불편한 점이나, 유지보수의 어려움 등을 가지고 있었다. (중략)

  • PDF

On Quasi-Static Crushing of a Stiffened Square Tube (보강된 정사각형 단면 강관의 정적 압괴거동에 관한 연구)

  • Paik, Jeom Kee;Chung, Jang Young;Chun, Min Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • A series of quasi-static crushing tests were carried out on thin-walled square tube specimens with axial and/or circumferential stiffeners including unstiffened specimens. The effective crushing length and mean crushing strength of the test specimens were investigated. Using the equivalent plate thickness approach, a simplified analytical model for predicting the mean crushing strength of stiffened square tubes has been developed.

  • PDF

Effect of Circumferential Wall Heat Conduction on Boundary Conditions for Convection Heat Transfer from a Circular Tube in Cross Flow (원관 주위의 대류 열전달에서 경계조건에 대한 원주방향 열전도의 영향)

  • 이상봉;이억수;김시영
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.39-45
    • /
    • 2001
  • With uniform heat generation from the inner surface of the cylindrical heater placed in a cross flow boundary condition, heat flow that is conducted along the wall of the heater creates a non-isothermal surface temperature and non-uniform heat flux distribution. In the present investigation, the effects of circumferential wall heat conduction on convection heat transfer is investigated for the case of forced convection around horizontal circular tube in cross flow of air. The wall conduction number which can be deduced from the governing energy equation should be used to express the effect of circumferential wall heat conduction. It is demonstrated that the circumferential wall heat conduction influences local Nusselt numbers of one-dimensional and two-dimensional solutions.

  • PDF

A Study on the Weld Line Position Optimization for Hydroforming (Hydroforming을 위한 Weld line 최적배치에 관한연구)

  • 전병희
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.160-168
    • /
    • 2000
  • Hydroforming is a metal forming process that enables circular metal tubes to be formed in to the parts with the complex cross section along the curved axial direction. Recently this hydroforming process is largely used for the production of the automotive parts. This paper presents the results of tube bending and hydroforming simulations in cases of the varying weld line positions of the tube. Ten cases of prebending and hydroforming simulations are carried out to find the optiaml weld line position.

  • PDF

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF