• Title/Summary/Keyword: True Time

Search Result 994, Processing Time 0.025 seconds

Effect of Reverse Screw Elements on the Residence Time Distribution in Twin-Screw Extruder (이륜형 압출기의 체류시간 분포에 대한 역피치 스크류의 효과)

  • Lim, J.K.;Wakamiya, S.;Noguchi, A.;Lee, C.H.
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.208-212
    • /
    • 1985
  • The residence time distributions were measured experimentally to determine the effect of reverse screw elements at various screw configurations in twin screw extruder. A simple model was used to estimate the number of filled C-chamber on the forwarding screw. The inclusion of reverse-screw elements resulted in the increase of median residence time and the broadening of color distribution. True residence time was affected by using the reverse screw elements just before the die. The number of filled C-chamber was decreased with the increase of screw revolution speed at the same screw configuration.

  • PDF

Design of a 10 GHz Phased-Array Antenna Using CFG True Time-Delays (CFG 실 시간지연 선로를 사용한 10 GHz 위상 배열 안테나의 설계)

  • 이갑용;최연봉;신종덕;김부균;이상배
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3C
    • /
    • pp.241-247
    • /
    • 2002
  • In this paper, we proposed a continuously variable true time-delay for transmit linear phased-array antenna sing chirped fiber gratings(CFGs) and a tunable laser source. Average group delay-slope of the CFG was treasured to be 177 ps/nm at L-, S-, and X-band. Simulation results show that the maximum gain of the transmit linear phased-array antenna with the beam steering angle of 180$^{\circ}$ is 11.6 dB at 10 GHz.

A Case Report of Gallbladder Duplication (중복담낭 1예)

  • Choi, Byung-Uk;Cho, Yong-Pil;Yoo, Shi-Joon;Kim, In-Koo;Min, Pyung-Chul
    • Advances in pediatric surgery
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 1996
  • Congenital duplication of the gallbladder, including true duplication and septated gallbladder, is an uncommon but potentially complicated malformation. It presents biliary colic associated with acute or chronic cholecystitis. It can be diagnosed preoperatively by various imaging tools such as real-time ultrasonography, biliary scintigraphy, oral cholecystography, or endoscopic retrograde cholangiography. It can be safely managed by either laparoscopic or open procedures. This report describes a 6-year-old girl with true duplication of gallbladder diagnosed preoperatively by real-time ultrasonography and treated by open cholecystectomy.

  • PDF

The Semantics of the English Progressive and the Imperfective Paradox

  • Yeom, Jae-Il
    • Language and Information
    • /
    • v.7 no.2
    • /
    • pp.139-161
    • /
    • 2003
  • The progressive in English is taken to be an operator which takes a non-stative predicate and returns a predicate which denotes a process with a temporal frame around some definite time or event. When, it is combined with a predicate which has a culmination in the event, the sentence means that the culmination has not come yet. So the event denoted by the base predicate is not true at the current time. On the other hand, when it is combined with a predicate which has no culmination in the event, the event denoted by the base predicate is taken to be true. In this paper, this is explained by the semantics of the progressive based on the notion of contributiveness. I propose that a progressive sentence is verified by some subevents which are contributive to the current situation and the progress of the event beyond the threshold level of the event denoted by the base predicate. A sub-situation is contributive if the addition of it to the previous situation is more likely to lead to the whole situation than the previous situation.

  • PDF

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

A Study on the Property Analysis of Software Reliability Model with Shape Parameter Change of Finite Fault NHPP Erlang Distribution (유한고장 NHPP 어랑분포의 형상모수 변화에 따른 소프트웨어 신뢰성 모형의 속성 분석에 관한 연구)

  • Min, Kyung Il
    • Journal of Information Technology Applications and Management
    • /
    • v.25 no.4
    • /
    • pp.115-122
    • /
    • 2018
  • Software reliability has the greatest impact on computer system reliability and software quality. For this software reliability analysis, In this study, we compare and analyze the trends of the properties affecting the reliability according to the shape parameters of Erlang distribution based on the finite fault NHPP. Software failure time data were used to analyze software failure phenomena, the maximum likelihood estimation method was used for parameter estimation. As a result, it can be seen that the intensity function is effective because it shows a tendency to decrease with time when the shape parameters a = 1 and a = 3. However, the pattern of the mean value function showed an underestimation pattern for the true values when the shape parameters a = 1 and a = 2, but it was found to be more efficient when a = 3 because the error width from the true value was small. Also, in the reliability evaluation of the future mission time, the stable and high trend was shown when the shape parameters a = 1 and a = 3, but on the contrary, when a = 2, the reliability decreased with the failure time. Through this study, the property of finite fault NHPP Erlang model according to the change of shape parameter without existing research case was newly analyzed, and new research information that software developers can use as basic guideline was presented.

Time Constant of a Fine-Wire Thermocouple Immersed to Fluids (유체에 잠겨있는 가는 열전대의 시간상수 측정)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.190-199
    • /
    • 1998
  • a new measuring method is suggested to determine the time constant of a thermocouple wire to be applied for the measurement of the true fluid temperatures in varying flow states. Based on the techniques of internal heating which are commonly used to measure mean time constants we extend the existing method to measure instantaneous time constants continuously. A method of measurement and analysis is presented and verified experimentally.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Using MIM Software 3-D PET / CT imaging for the evaluation of radiation therapy on the clinical application of research (MIM 소프트웨어를 이용한 3-D PET/CT 영상의 방사선치료 평가를 위한 임상적용에 관한 연구)

  • Lee, SangHo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.249-255
    • /
    • 2015
  • In this study, through the additional information of the PET / CT images by utilizing the basic data of TPS clinical application on the basis of the image re-forming synthetic function, the True-D technology and MIM software for continued research and development in combination, based on the combination-work between the respective images, reducing the time and cost of useful reading in clinical wide use of image width, efficient, effective tool for tumor targeting at diagnosis and radiation therapy by use as, by using the precise therapeutic effect determination, the time taken to read in the clinical, unnecessary and expect to a can reduce the additional examination by the creation of tumor patients read reports and PACS such asWe expect to be utilized for compatibility development with other software to evaluate the performance of PET / CT equipment.

Compensation Algorithm of Beamforming Error for Wideband Conformal Array Antenna (광대역 컨포멀 위상 배열 안테나의 빔형성 열화 보상 알고리즘)

  • Yoon, Ho-Joon;Lee, Kang-In;Nam, Sang-Wook;Chung, Young-Seek;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.6
    • /
    • pp.478-486
    • /
    • 2017
  • In this paper, we propose an algorithm for the wideband beamforming in a conformal phased array antenna by compensating the errors. For the wideband beamforming, we used the True Time Delay(TTD), which was fabricated on the RF circuit board to obtain long delay lines. Beamforming errors in the conformal array antenna are the mutual coupling between the array elements, the dispersive error in the TTD circuit, and the quantization error by the digital control. We apply the compensation algorithm to the conformal phased array antenna of wideband 2~4 GHz, and verify the usefulness by comparing the results with the experiment results.