• 제목/요약/키워드: Triple test

검색결과 211건 처리시간 0.025초

MJM 주입공법의 현장적용성에 관한 연구 (A Study on the Application of MJM for Ground)

  • 천병식;최춘식;노종륜;이승준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.437-442
    • /
    • 2005
  • The high pressure jet grouting method is mainly used in the grouting. But, this method has problems that the scale and strength of improved body is not constant with ground condition. Considering these problems, triple rod MJM that results in the high-strength effect by the technology of the injected ${\phi}7mm$ cement mortar was developed. In this MJM, the unconfined strength is estimated with the various combination ratio and engineering characteristic, strength improvement effect of improved body, was checked through the field test. It is known that the application of MJM was verified with ground and construction condition.

  • PDF

Effects of Offset Gate on Programing Characteristics of Triple Polysilicon Flash EEPROM Cell

  • Kim, Nam-Soo;Choe, Yeon-Wook;Kim, Yeong-Seuk
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권3호
    • /
    • pp.132-138
    • /
    • 1997
  • Electrical characteristics of split-gate flash EEPROM with triple polysilicon is investigated in terms of effects of floating gate and offset gate. In order to search for t the effects of offset gate on programming characteristics, threshold voltage and drain current are studied with variation of control gate voltage. The programming process is believed to depend on vertical and horizontal electric field as well as offset gate length. The erase and program threshold voltage are found to be almost constant with variation of control gate voltage above 12V, while endurance test indicates degradation of program threshold voltage. With increase of offset gate length, program threshold voltage becomes smaller and the drain source voltage just after program under constant control gate voltage becomes higher.

  • PDF

Helicobacter heilmannii 균 감염이 확인된 개에서의 위장염 발생 증례 (Gastritis in a Dog Infected with Helicobacter heilmannii)

  • 황철용;윤화영;한홍율
    • 한국임상수의학회지
    • /
    • 제19권3호
    • /
    • pp.375-378
    • /
    • 2002
  • A 3-year-old intact female korean pungsan dog showing chronic intermittent vomiting and anorexia was admitted to The Veterinary Medical leaching Hospital of Seoul National University. The patient had been received antiemetics, antacids or proton pump inhibitor for these symptoms but had not been recovered yet. All results of physical examination, complete blood count, serum chemical analysis, fecal test and radiography were normal. Gastric endoscopic examination was also performed and gastritis with hemorrhage on near antrum region was detected. In PCR assay of bioptic gastric tissues for detecting Helicobacter species infection, Helicobacter heilmannii infection was confirmed. After receiving triple therapy with amoxicillin, metronidazole and omeprazole for 21 days, all symptoms were recovered and had not been occurred again. Helicobacter heilmannii also were not detected.

CNC 선반가공(旋盤加工)에서 절삭조건(切削條件)에 따른 알루미늄의 표면(表面)거칠기 변화(變化) (The Surface Roughness of Aluminium Material according to Cutting Conditions in the CNC Lathe Working)

  • 김태욱;손기동
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.201-208
    • /
    • 2002
  • The machine tool which operates by hand is replacing by CNC machine tool to improve the quality of the product and the productivity in modem mechanic industry. The precision of machine part is influenced greatly the surface roughness by cutting condition of machine tool. So this study was performed to examine the aluminium surface roughness of section according to change of strength rating, nose radius, cutting speed, using live center. The results of this study are as follows; 1. In the case of 56mm diameter of test piece(length is below triple of diameter), whether establish the live center or not, doesn't influence to the surface roughness, and it is possible to make product without the live center. 2. The average surface roughness of 42mm diameter(length is quadruple of diameter) is similar to the 56mm diameter in the cutting condition of nose radius 0.8mm and cutting speed 140mm/min, but there are increases and differences in other cutting conditions. 3. In the case of test piece length more 70m/min(140m/mm) and nose radius improved greatly using the live center. 4. In the case of test piece length is quintuple of diameter, the nose radius must choose big tool and increase the cutting speed in preference live center establishment availability to improve that is surface roughness. Conclusively, if aluminum test piece length is fewer than triple of diameter, can process without establishing live center. If aluminum test piece length is more than quintuple of diameter, cutting conditions to improve surface roughness are (1) cutting speed (2) nose radius (3) whether the live center uses or not.

  • PDF

Effects of the Active Static Stretching and Eccentric Exercise of Hamstring Muscles on Flexibility, Strength, and Agility Performance

  • Kang, Ji-Hun;Kang, Eun-Hyo;Jeon, Jeongwoo;Hong, Jihoen;Yu, Jaeho;Kim, Jinseop;Kim, Seong-Gil;Lee, Dongyeop
    • 대한통합의학회지
    • /
    • 제10권2호
    • /
    • pp.115-123
    • /
    • 2022
  • Purpose : The hamstring is a group of three muscles, biceps femoris, semitendinosus, and semimembranosus, placed behind the thigh. The hamstring is one of the most commonly injured muscles and usually occurs during high-speed, high-intensity exercise. The purpose of this study was to investigate the effect of static stretching and eccentric exercise of hamstrings on flexibility, strength, and functional performance. Methods : This study was conducted on 28 healthy adults. Subjects were divided into a static stretching group (n=15) and an eccentric exercise group (n=13). Subjects measured hamstring flexibility (active knee extension test), hamstring strength (concentric and eccentric peak torque), and functional performance (triple hop for distance and modified 20 m sprint). The intervention was conducted three times a week for six weeks. To compare the difference between values before and after the intervention, paired t-test was used, and an independent t-test was used to compare between groups. Results : In both groups, the active knee extension test, concentric peak torque, triple hop test, and 20 m sprint significantly increased after the intervention compared to before the intervention (p<.05). However, no significant difference was found in eccentric peak torque after intervention in both groups (p>.05). No significant difference was found between the two groups in the effect on the variables (p>.05). Conclusion : Both interventions were found to be effective for flexibility, concentric strength, and functional performance. Eccentric exercise and static stretching are recommended to improve the flexibility and functional performance of the hamstring. This study's results will be considered essential data on the effectiveness of static stretching and eccentric exercise.

유선형 스텝 선형을 적용한 35 knot급 고속활주선의 성능평가에 대한 고찰 (A Review on the Performance Test of a High-Speed Planing Hull with 35 knot Speed by Appling the Streamlined Step of Hull Form)

  • 문병영;고호남;이기열
    • 한국해안·해양공학회논문집
    • /
    • 제30권3호
    • /
    • pp.95-102
    • /
    • 2018
  • 고속 주행시 마찰저항을 감소시키기 위해 선체의 선저부분의 모양을 변화시키는 등 최근 관련 분야의 개발이 이루어지고 있는 바, 본 개발에서는 기하학적으로 고속활주선의 스텝 단면을 유선형(streamlined type) 구조로 제작해 침수 표면적에 의한 마찰저항의 최소화를 목적으로 준비하였다, 본 개발의 목적은 어업의 각종 위급상황 및 안전성을 고려한 고속활주선의 구조설계를 기반으로 하여 어업의 특수성 및 작업특성(어군 추적 및 어획물 출하)을 고려한 최적선형으로서 유선형 마찰저감형 고속활주선을 제작하는데 그 목표가 있으며, 이 과정에서 제작된 성과물에 대한 성능평가를 수행하여 정량적 목표치를 확보하고자 함에 본 기술개발 논문의 소개 배경이 있다.

효소면역법을 이용한 Brucella abortus 항체 검출에 관한 연구 (Studies on enzyme-linked immunosorbent assay(ELISA) for detection of antibody to Brucella abortus)

  • 심항섭;국정희;정봉수;고태오;조중현;박유순
    • 한국동물위생학회지
    • /
    • 제21권2호
    • /
    • pp.107-115
    • /
    • 1998
  • In order to establish a rapid, sensitive and specific diagnostic method for detection of antibody to Brucella abortus, a enzyme-linked immunosorbent assay(ELISA) was adapted. The diagnostic efficacy of the established ELISA was compared with that of the standard tube agglutination test for B abortus. 1. It was found that the optimal concentration of antigen for this ELISA was 5$\mu\textrm{g}$/ml, the optimal dilution of conjugate was 1 : 2000, and the optimal dilution of serum was 1 : 200, respectively. 2. Cut off value in this ELISA was 1,102 that was determined by mean absorbance(at 492nm) of tube agglutination test negative serum added with the triple value of the standared devation. 3. The relationship between the tube agglutination test and ELISA was showen high corresponding rate with sensitivity(96.3%) and specificity(98.1%). 4. The efficacy of the ELISA for detection of B abortus antibody was compared with tube agglutination test In brucellosis outbreak farm. The sensivity of ELSIA was higher than tube agglutination test.

  • PDF

A General Solution of Determining Storage Coefficient From Multi-Step Pumping Test Recovery Data

  • Jin-Yong Lee;Kang-Kun Lee
    • 대한지하수환경학회지
    • /
    • 제7권1호
    • /
    • pp.20-23
    • /
    • 2000
  • 양수시험시 획득되는 회복자료만을 이용하여 저유계수를 추정하는 일반해를 제시하였다. Banton and Bangoy(1996)가 제시한 단 단계(single-step) 양수시험에서 얻는 회복자료를 이용한 저유계수 추정해를 일반적인 다단계 (multi-step)시험 회복자료에도 적용 가능하게 확장한 것이다. 본 연구에서 구한 일반 해를 이용하여 저유계수와 투수계수를 구한 결과 다른 방법으로 구한 결과 값과 잘 일치하였다.

  • PDF

TPS를 고려한 광가입자망에서의 QoS 고찰 (A QoS policy experimentation and evaluation on Optical subscriber network Test bed for deploying TPS(Triple Play Service))

  • 이동열;성민모;김희동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.63-67
    • /
    • 2009
  • In this paper we propose a QoS policy, which is based on both DSCP and SPQ, appropriate to TPS users on optical subscriber network. Then we experiment and evaluate QoS policy through the test bed which emulates real optical subscriber network. In order to perform effective and real experiment on test bed we make test traffic equivalent to 400 TPS users and give it to test bed. The experimental result shows that no packet loss in real time service traffic such as voice, IPTV occurs during more than 4 hours. We think that our proposed QoS policy is a proper method which guarantees the service quality of real time services on optical subscriber network.

  • PDF

FR, NR 측정 방식을 이용한 IPTV 품질에 관한 연구 (A Study on The IPTV Quality Using FR or The NR Measurement)

  • 이재정;남기동;김창봉
    • 대한전자공학회논문지TC
    • /
    • 제46권8호
    • /
    • pp.59-66
    • /
    • 2009
  • 최근 국내 인터넷망의 개선과 TPS(Triple Play Service : 데이터+영상+음성) 서비스를 위한 가입자망의 고도화로 IPTV(Internet Protocol TV) 서비스의 품질에 대한 기대치가 급격히 높아지고 있다 따라서, 가입자의 실시간 동영상 품질을 보장할 수 있는 IPTV 서비스 품질에 대한 국내 품질 기준 및 국제 표준의 재정이 시급히 필요하다. 본 논문은 서비스 사업자 네트워크의 특성과 유사한 환경에서 시험하기 위해 방송/VoD(Video on demand)를 제공하는 헤드엔드 영역과 상용 네트워크 특성을 나타내는 트래픽/라우팅 부하 생성 장비와 네트워크 Impairment 장비 및 다수의 이기종 라우터를 포함하는 네트워크 영역과 가입자 셋탑박스 영역으로 테스트베드를 구축하였다. 그리고 구축된 환경을 이용하여 서비스 환경의 변화에 따른 품질 시험으로 IPTV 서비스의 품질기준 결정에 필요한 특성을 제시한다.