• Title/Summary/Keyword: Trip Bar

Search Result 6, Processing Time 0.017 seconds

Partial Discharge Characteristics of Ultra-High Voltage Cable Insulators by Needle Electrode (침 전극에 의한 초고압 케이블 절연재료의 부분방전 특성)

  • Kim, Gyun-Sig;Choi, Beom-Kyu;Byun, Doo-Gyoon;Cho, Kyung-Soon;Kim, Gwi-Yeol;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.477-480
    • /
    • 2004
  • In other to estimate an electrical properties of the cross linked polyethylene cable, the partial discharge properties due to charge of electrode shape(needle and bar) and void size were investigated at room temperature. Fast trip and breakdown time were appeared by the closed of needle electrode. The trip and breakdown voltage depend on insulator thickness. As the result, confirmed larger effect of void size than effect of insulator thickness. The effect of voids size than influence of insulation thickness was dominated by internal an electrode of inner insulators.

  • PDF

A Study on the Retained Austenite and Tensile Properties of TRIP Type High Strength Steel Sheet with Cu (Cu 함유 TRIP형 고장력 강판의 잔류오스테나이트 및 인장특성에 관한 연구)

  • Kang, C.Y.;Kim, H.J.;Kim, H.G.;Sung, J.H.;Moon, W.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.3
    • /
    • pp.231-239
    • /
    • 1999
  • Volume fraction and morphology of retained austenite, tensile properties of TRIP type high strength steel sheet with Fe-C-Si-Mn-Cu chemical composition have been investigated. The retained austenite of granular, bar and film type existing in specimen was obtained after intercritical annealing and austempering. The granular type retained austenite increased with increase of intercritical annealing and austempering temperature. With increase of intercritical annealing temperature, retained austenite and carbon contents increased. Maximum contents of retained austenite was obtained by austempering at $400^{\circ}C$. The maximum tensile strength was obtained by austempering at $450^{\circ}C$ and maximum elongation was obtained at $400^{\circ}C$. T.S${\times}$E.L value increased with increase of retained austenite contents due to the elongation strongly controlled by contents of retained austenite, but tensile strength was affected with various factors such as bainitic structure etc.

  • PDF

Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS (PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.8-13
    • /
    • 2014
  • The purpose of this study is to analyze the damage pattern when overcurrent is applied to a thermal magnetic type molded case circuit breaker (MCCB) using a Primary Current Injection Test System (PCITS). When an overcurrent of 150 A was applied to the PCITS for 5 seconds with the trip bar of an MCCB being damaged, it was found that the surface of the temperature control device (bimetallic strip) positioned at the right was significantly carbonized. When an overcurrent of 300 A was applied to the PCITS for 5 s under the same conditions, the entire temperature control device was deteriorated, becoming flattened and in close contact with the MCCB. When an overcurrent of 450 A was applied to the PCITS for 5 s, the coil of the temperature control device was melted and disconnected. In addition, it was observed that the contacts, the enclosure and upper cover were deformed and there was a trace of carbonization on them. When approximately 3 s had elapsed after an overcurrent of 600 A was applied, white smoke occurred inside the MCCB and a flame was radiated out, after which the overcurrent supply stopped with "phutt" (whomp) sound. It was observed that when the same type of MCCB is damaged by a general flame, the surfaces of its handle, terminal, arc divider (extinguisher) and temperature control device were carbonized uniformly. In addition, it was found that the trip bar of the operating mechanism was melted down and the metal operation pin was moved while being tripped.

Comparison of Standards for a 1ϕ 2 W MCCB and Study on the Evaluation of Heat Resistance Characteristics (1ϕ 2 W MCCB의 기준 비교 및 내열 특성 평가에 관한 연구)

  • Choi, Chung-Seog;Lee, Jae-Hyuk
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • This study obtained the following results by analyzing the standards related to a $1{\phi}$ 2W MCCB and evaluating its heat resistance characteristics. Since KS C 8321 corresponds to IEC 60947-2 standards, most of the related regulations are similar. The NFPA, which presents the user oriented safety regulations, contains no details about tests or inspections, etc., but it does specify in detail the regulations directly related to safety. It can be seen that KS C 8321 classifies in detail the items about tests and inspections. However, IEC 60947-2 and IEEE C37.51 simplified the test and inspection items or omitted some of them. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state. In addition, most of the fixing hanger was melted down, losing their function. When applying thermal stress to the MCCB at $90^{\circ}C$, it showed nothing peculiar, but the fixing hanger was partly deformed at $105^{\circ}C$ and $120^{\circ}C$. It was found that the fixing hanger was deformed and the name plate was discolored at $150^{\circ}C$. It can be seen from the analysis of the internals of the MCCB that the trip bar has been melted away and that the up and down operator has moved up. The experiment performed by applying a withstanding voltage of 6 kV for 60 s showed that all items remained intact. In addition, the evaluation of the insulation performance performed by applying DC 500 V using an insulation-resistance tester showed good insulation performance.

A Study of the Living Culture of Transnational Married Women and of Children's Outdoor Plays in their Hometown : Jilin Province - Jian in China (이주여성 출신 지역 생활문화와 아동놀이에 관한 연구 : 중국 길림성 집안시를 중심으로)

  • Song, Soon
    • Journal of Families and Better Life
    • /
    • v.28 no.1
    • /
    • pp.131-143
    • /
    • 2010
  • The purpose of this study is to understand the living culture of transnational married women and to analyze the out door play of children in their hometown. The data was collected through observation from 27th June to 7th July 2008 in Jian, Jilin Province China. The children's play and lifestyles were observed, and data pertaining to the culture of the people were collected by a teacher and staff. We also visited the residents for housing information. The results are given below. 1. They dressed in Korean clothes on festive days and the boys put on a hood. They had eating habits which included cooking for themselves or buying semi-manufactured goods but did not use, instant food. The housing habits involved a combination of cooking and heating by Korean floor heating system(Ondol). They utilized outdoor space to grow vegetables. Those with a fulltime job(teacher) preferred to live in an apartment but an apartment was too expensive. Public utility charges and traffic expenses were cheap. 2. The main festive days are the lunar New Year's Day and Chuseok. The children returned home and enjoyed the festive day with their parents. The language used are Korean language and Chinese. Some Korean words and phrases in Jian Joseonjok have different meanings as compared to how they are used in Korea. A capping ceremony did not to celebrate becoming an adult from an adolescent. Couples performed a wedding ceremony at a wedding hall attended by their parents and invited relatives from both families. The relatives gave the couple a wedding gift. They did not go on a wedding trip as it was not affordable but instead spent their wedding night at a hotel in this culture. When someone dies, they bury the body after cremation. They perform a memorial service for three years on the birthday of the departed. They have a banquet on the 60th birthdays with their relatives and neighbours and are typically presented with a carp for longevity. 3. They understand capitalism and therefore send their children to school to improve their social position. The Korean and Chinese languages are required subjects in school. The students choose a second language(English or Russian). They prefer English class but at the time of this study an English class was not offered at the school in Jian Joseonjok. Therefore the children entered a Chinese school. 4. The children play outdoor games such as Y$\acute{a}$o J$\grave{i}\bar{a}$(要家), X$\grave{i}$ang g$\grave{i}$(象棋), T$\grave{i}\grave{a}$o p$\acute{i}$ j$\grave{i}$n(r)(跳皮節), D$\grave{o}$uch ing g$\grave{u}$n 凍冷根, B$\bar{e}$i B$\bar{e}$i 背背, and soccer. They play games according to the season.

The Effect of the Circuit Exercise and Conventional Exercise on Walking Ability in Chronic Stroke (순환운동과 전통적 운동이 만성 뇌졸중환자의 보행능력에 미치는 효과)

  • Song, Woo-Seok;Park, Min-Chull;Shim, Je-Myung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.193-201
    • /
    • 2010
  • Purpose : This study achieved to search the effect of the circuit exercise and conventional exercise on walking ability(walking speed, endurance, dynamic balance, speed, endurance and pedestrian crossing) in chronic stroke. Methods : Since is diagnosed by stroke, to 30 chronic stroke patients who more than 1 year past the 15 circuit exercise group, the 15 conventional exercise group random the circuit exercise group applied circuit exercise 3th 8 weeks each week after neurological treatment because assigning and the conventional exercise group executed round trip walk exercise in parallel bar 3th 8 weeks each week after neurological treatment. The data of 25 patients who complete experimental course were statistically analysed. Results : The results of this dissertation were as following : 1) There were significantly increased after experimental of 10 meter walk test, 6 minutes walk test and Timed "Up and Go" test in circuit exercise group (p<.001). 2) There were significantly increased after experimental of 2, 4 and 6 lane road crossing mobility in Walking circuit exercise group(p<.01). 3) There were significantly differences after experimental of 10 meter walk test, 6 minutes walk test and Timed "Up and Go" test change quantity between circuit exercise group and conventional exercise group(p<.05). 4) There were correlations were found between the TUG test and 2, 4 and 6 lane road (2 lane road; r=.463, p<.01., 4 lane road; r=515, p<.01., 6lane road; r=.710, p<.01), and there were correlations were found between the 10 meter walk test and 6 minutes walk test(r=.595, p<.01), TUG test(r=.662, p<.01) and 6 lane road(r=.527, p<.01). Conclusion : Even if improvement of walk function through training consists in room, transfer of actuality pedestrian crossing is no change outside the room. Because it is much variable of the weather, seasonal factor, temperature, pedestrian number, state of underneath etc. outside the room. Then, in room after direction promotion of walk function to be promotion of walk function in actuality life and need development of connectable training method consider.