• 제목/요약/키워드: Trios

검색결과 46건 처리시간 0.027초

Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study

  • Gozde, Kaya;Caglar, Bilmenoglu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.388-398
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept. MATERIALS AND METHODS. Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed. For the control group, the gypsum model was scanned 10 times with an industrial scanner. The first of the 10 virtual models obtained from the industrial model was chosen as the reference model. For trueness, the data of the 14 dental scanners were superimposed with the reference model; for precision, the data of all 14 scanners were superimposed within the groups. Statistical analyses were performed using the Kolmogorov-Smirnov, Shapiro-Wilks, and Dunn's tests. RESULTS. Primescan showed the highest trueness and precision values (P < .005), followed by the iTero 5D scanner (P < .005). CONCLUSION. Some of these digital scanners can be used to make impressions within the All-on-4 concept. However, the possibility of data loss due to artifacts, reflections, and the inability to combine the data should be considered.

치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구 (Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation)

  • 박주희;설정환;이준재;이승표;임영준
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.104-115
    • /
    • 2018
  • 목적: 본 연구는 현재 시판되고 있는 구강스캐너를 사용하여 구강스캐너 정확도 평가를 위해 국제표준이 제안하고 있는 모형의 스캔이미지 획득이 가능한 지 분석하고, 이를 통해 표준모델이 가지고 있는 문제점을 파악하는 데 있다. 연구 재료 및 방법: ISO12836과 ANSI/ADA no.132에서 규정하는 국제표준을 참고하여 3D 프린터기를 이용하여 모델을 제작하였으며, 모델스캐너와 두 가지 구강스캐너를 이용하여 스캔을 하였다. 스캔이미지 획득 정도를 3등급으로 분류하여 스캐너의 성능을 비교하였으며, 모델 표면의 상태에 따른 이미지 획득 능력도 비교하였다. 결과: 모델 스캐너가 모든 모델에서 가장 우수한 이미지를 얻을 수 있었으며 TRIOS3는 둥근 형태의 구조물, CS3500은 각진 형태의 구조물에 대한 이미지 재현이 좋은 결과를 보였다. 표준 모델의 표면상태에 따른 스캔이미지 재현에서는 초경석고 모델이 스캐너 종류와 관계없이 가장 우수하였다. 3D 프린팅 모델의 경우, 표면에 파우더 처리를 한 모델에서 가장 우수한 스캔이미지를 얻을 수 있었다. 결론: ISO12836과 ANSI/ADA 132의 표준모델의 경우, 구강스캐너의 field of view (FOV)를 벗어나는 구조물을 스캔할 때 서로 다른 면인 것을 구분하는 기준점이 존재하지 않게 되면 연속적인 스캔 및 정합과정에서 정확한 이미지를 나타내지 못한다는 것을 알 수 있었다. 그러므로 단순한 패턴의 반복과 대칭구조를 가지지 않는 새로운 표준모델이 필요하다고 여겨진다.

Comparing the accuracy of six intraoral scanners on prepared teeth and effect of scanning sequence

  • Diker, Burcu;Tak, Onjen
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.299-306
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the accuracy of six recently introduced intraoral scanners (IOSs) for single crown preparations isolated from the complete arch, and to determine the effect of scanning sequence on accuracy. MATERIALS AND METHODS. A complete arch with right and left canine preparations for single crowns was used as a study model. The reference dataset was obtained by scanning the complete arch using a highly accurate industrial scanner (ATOS Core 80, GOM GmbH). Six different IOSs (Trios, iTero, Planmeca Emerald, Cerec Omnicam, Primescan, and Virtuo Vivo) were used to scan the model ten times each. The scans performed with each IOS were divided into two groups, based on whether the scanning sequence started from the right or left quadrant (n=5). The accuracy of digital impression was evaluated using three-dimensional analyzing software (Geomagic Studio 12, 3D Systems). The Kruskal Wallis and Mann- Whitney U statistical tests for trueness analysis and the One-way ANOVA test for precision analysis were performed (α=.05). RESULTS. The trueness and precision values were the lowest with the Primescan (25 and 10 ㎛), followed by Trios (40.5 and 11 ㎛), Omnicam (41.5 ㎛ and 18 ㎛), Virtuo Vivo (52 and 37 ㎛), iTero (70 and 12 ㎛) and Emerald (73.5 and 60 ㎛). Regarding trueness, iTero showed more deviation when scanning started from the right (P=.009). CONCLUSION. The accuracy of digital impressions varied depending on the IOS and scanning sequence used. Primescan had the highest accuracy, while Emerald showed the most deviation in accuracy for single crown preparations.

Differential Parental Transmission of Markers in BCL3 among Korean Cleft Case-parent Trios

  • Park, Beyoung-Yun;Sull, Jae-Woong;Park, Jung-Yong;Jee, Sun-Ha;Beaty, Terri H.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2009
  • Objectives : Isolated cleft lip with or without cleft palate(CL/P) is among the most common human birth defects, with a prevalence of approximately 1 in 700 live births. The B-Cell Leukemia/lymphoma 3(BCL3) gene has been suggested as a candidate gene for CL/P based on association and linkage studies in some populations. This study tests for an association between markers in BCL3 and isolated, non-syndromic CL/P using a case-parent trio design, while considering parent-of-origin effects. Methods : Forty case-parent trios were genotyped for two single nucleotide polymorphisms(SNPs) in the BCL3 gene. We performed a transmission disequilibrium test(TDT) on individual SNPs, and the FAMHAP package was used to estimate haplotype frequencies and to test for excess transmission of multi-SNP haplotypes. Results : The odds ratio for transmission of the minor allele, OR(transmission), was significant for SNP rs8100239(OR=3.50, p=0.004) and rs2965169(OR=2.08, p=0.027) when parent-of-origin was not considered. Parentspecific TDT revealed that SNP rs8100239 showed excess maternal transmission. Analysis of haplotypes of rs2965169 and rs8100239 also suggested excess maternal transmission. Conclusions : BCL3 appears to influence risk of CL/P through a parent-of-origin effect with excess maternal transmission.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.

Botcillus subtilis에서 인삼 saponin의 triol fraction에 의한 C-AMP농도 감소가 filament생성에 미치는 효과 (Effect of Triol Fraction of Ginseng Saponin on Filamentous Formation through Reduction in C-AMP Concentration in Bacillus subtizis.)

  • 조영동;최수영
    • Journal of Ginseng Research
    • /
    • 제7권1호
    • /
    • pp.63-67
    • /
    • 1983
  • Bacillus subtilis grown on medium containing 0.1% trios fraction, 0.005% sodium deoxycholate, and 0.05% taurocholate respectively was shown to grow as filamentous form and contain 2.3 x 10-5M, 1 x 10-5M, and 2.3${\times}$10-5M of intracellular C-AMP, respectively. The concentration was 3 or 4 times lower than that of the control. But concentrations of extracellula: C-AMP were similar to that of the control. Such decrease in C-AMP concentration was shown to parallel with decrease in autolysin activity indicating 40% and 20% lower activity of Bacillus subtilis grown on medium containing 0.05% and 0. l% triol fraction respectively than that of the control, The activity was also shown to be in inverse proportion with the formation of filament .

  • PDF

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.

한국인 자폐 스펙트럼장애에서 Tryptophan 2,3 Dioxygenase(TDO2)유전자 다형성-가족 기반 연구 (Family-Based Association Study of Tryptophan-2,3 Dioxygenase(TDO2) Gene and Autism Spectrum Disorder in the Korean Population)

  • 김순애;박미라;조인희;유희정
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제18권2호
    • /
    • pp.123-129
    • /
    • 2007
  • Objectives: Autism is a complex neurodevelopmental spectrum disorder with a strong genetic component. Previous neurochemical and genetic studies have suggested the possible involvement of the serotonin system in autism. Tryptophan 2,3-dioxygenase(TDO2) is the rate-limiting enzyme in the catabolism of tryptophan, which is the precursor of serotonin synthesis. The aim of this study was to investigate the association between the TDO2 gene and autism spectrum disorders(ASD) in a Korean population. Methods: The patients were diagnosed with ASD on the basis of the DSM-IV diagnostic classification outlined in the Korean version of the Autism Diagnostic Interview-Revised and Autism Diagnostic Observation Schedule. The present study included the detection of four single nucleotide polymorphisms(SNPs) in the TDO2 gene(rs2292536, rs6856558, rs6830072, rs6830800) and the family-based association analysis of the single nucleotide polymorphisms in Korean ASD trios using a transmission disequilibrium test(TDT) and haplotype analysis. The family trios of 136 probands were included in analysis. 87.5% were male and 86.0% were diagnosed with autism. The mean age of the probands was $78.5{\pm}35.8$ months(range: 26-264 months). Results: Two SNPs showed no polymorphism, and there was no significant difference in transmission in the other two SNPs. We also could not find any significant transmission in the haplotype analysis(p>.05). Conclusion: We could not find any significant statistical association between the transmission of SNPs in the TDO2 gene and ASD in a Korean population. This result may not support the possible involvement of the TDO2 gene in the development of ASD, and further exploration might be needed to investigate other plausible SNP sites.

  • PDF

엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구 (Evaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study)

  • ;박지만
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.282-289
    • /
    • 2020
  • 목적:본 연구의 목표는 다른 유형의 엔도크라운(endocrown) 와동 형태를 세 가지 다른 구강스캐너로 디지털 인상을 채득하였을 때의 정확성을 평가하는 것이다. 재료 및 방법: 두 개의 인체 하악 대구치를 협측벽이 있는 것(Class 2)과 협측벽이 없는(Class 3), 두 가지 엔도크라운 지대주 디자인으로 치아형성 하였다. 와동 디자인 2종을 레퍼런스로 탁상용 스캐너(E3, 3shape)와 세 개의 다른 구강스캐너, Trios 3 (3shape, TRI group), Cerec Omnicam (Dentsply Sirona, CER group), i500 (Medit Corp., I5 group)로 스캔하였다. 표준 테셀레이션 언어(.stl) 데이터 세트를 얻어, 계측 소프트웨어에서 불러들였다. 각 구강스캐너로 획득한 반복된 스캔 데이터 사이의 편차에 기초하여 정밀도(precision)를 평가하였다. 기준 데이터와 반복하여 얻은 구강스캔 사이의 편차로서 진도(trueness)를 평가 하였다. 상호작용을 탐지하기 위해 데이터는 일변량 분산분석(ANOVA)을 사용하여 통계적으로 분석하였고, 실험군의 비교 분석을 위해 데이터는 .05의 유의 수준에서 일원 분산분석 및 사후 Tukey 테스트로 분석하였다. 결과: I5 군의 두 와동 형태에 대한 편차값은 진도의 측면에서 다른 구강스캐너 군에 비해 낮았다. 두 와동 디자인 모두에서 TRI 군은 다른 구강스캐너군 보다 우수한 정밀도를 보였다. 결론: 구강스캐너의 다양한 기술과 다양한 엔도크라운 치아형성 디자인이 디지털 스캔의 정확도에 영향을 미쳤다.

구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례 (Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report)

  • 장윤정;김홍준;송미경;문지은;이한라;박찬익
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.234-243
    • /
    • 2015
  • 디지털 기술의 발달로 무치악 부위의 임플란트 수복 시 그 진단과 치료 과정 전반에 걸쳐 구강 내 3차원 정보를 데이터화하여 보철물을 제작하는 것이 가능해졌다. 전통적인 인상채득 방식을 이용하여 모델을 만들고 이것을 스캔하여 보철물을 제작하던 CAD/CAM 이용 방식에서 벗어나 디지털 인상 코핑(scanbody)을 사용함으로써 모델 없이 디지털 인상을 채득하고 임플란트 임시 보철물 및 해부학적 지대주를 제작하는 술식으로 변화하고 있다. 그러나 아직 이러한 술식은 활발히 이루어지고 있지 않으며 특히 심미성이 요구되어 연조직 외형의 인기가 중요한 상악 전치부 임플란트 즉시 부하에서의 사용은 그 사례가 많지 않다. 이에 따라 본 증례 보고에서는 3명의 상악 전치부 단일 임플란트 수복 환자에서 디지털 인상 코핑(scanbody)을 체결한 후 구강 내 스캐너인 CEREC Omnicam (Sirona, Bensheim, Germany) 또는 Trios (3shape, Copenhagen, Denmark)로 디지털 인상채득을 통해 임플란트 지대주 및 임시 보철물을 제작하였다. 그 결과 디지털 인상채득을 통한 편리성, 정확성 그리고 최종 보철물의 양호한 심미성을 얻어 보고하고자 한다.