• Title/Summary/Keyword: Trimmed Method

Search Result 99, Processing Time 0.022 seconds

Consolidation Test Method Considering Sample Deformation Due to Stress Release by Sampling (시료채취에 의한 응력해방시 시료변형을 고려한 압밀시험)

  • Kim Jae-Young;Takada Naotoshi
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.99-105
    • /
    • 2004
  • When a saturated clay is sampled from a borehole in an undisturbed manner, the exerted negative pore water pressure restricts the volume expansion. The vertical and horizontal stresses to which the clay was subjected in the ground are smaller and larger than this isotropically confining stress equivalent to the mean principal stress in the ground, respectively. Therefore the sample expands vertically and shrinks laterally under an undrained condition. In the ordinary consolidation test, the sample thus deformed is trimmed to fit the inside of the consolidometer ring. Thus, the specimen generates larger consolidation displacement due to confining larger horizontal stress when in-situ effective pressure is loaded. The specimen does not reproduce the in-situ consolidation behavior, In this paper, considering sample deformation, the test specimen is made to expand laterally to fit the inside of the ring in the undrained manner when the in-situ effective pressure is loaded. And applicability of this proposed test procedure was verified; results from the conventional consolidation test procedure are also discussed.

Study on Performance Analyses on Coaxial Co-rotating Rotors of e-VTOL Aircraft for Urban Air Mobility (도심 항공 교통을 위한 전기동력 수직 이착륙기의 동축 동회전 로터의 성능해석 연구)

  • Lee, Yu-Been;Park, Jae-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.12
    • /
    • pp.1011-1018
    • /
    • 2021
  • This numerical study conducts the modeling and the hover performance analyses of coaxial co-rotating rotor(or stacked rotor), using a rotorcraft comprehensive analysis code, CAMRAD II. The important design parameters such as the index angle and axial spacing for the coaxial co-rotating rotor are varied in this simulation study. The coaxial co-rotating rotor is trimmed using the torque value of the upper rotor of the previous coaxial counter-rotating rotor or the total thrust value of the previous coaxial counter-rotating rotor in hover. The maximum increases in the rotor thrust is 1.84% for the index angle of -10° when using the torque trim approach. In addition, the maximum decreases in the rotor power is 4.53% for the index angle of 20° with the thrust trim method. Thus, the present study shows that the hover performance of the coaxial co-rotating rotor for e-VTOL aircraft can be changed by the index angle.

A study on the residual stress and spring back of thermoformed films (열성형 공정에서 발생하는 필름의 잔류응력 및 스프링 백에 관한 연구)

  • Park, Du-Yong;Park, Dong-Hyun;Lee, Ho-Sang
    • Design & Manufacturing
    • /
    • v.16 no.1
    • /
    • pp.27-35
    • /
    • 2022
  • Thermoforming is a plastic manufacturing process that applies a force to stretch a film of heated thermoplastic material over an engineered mold to create a 3-dimensional shape. After forming, the shaped part can then be trimmed and finished to specification to meet an end-user's requirements. The process and thermoplastic materials are extremely versatile and can be utilized to manufacture parts for a very wide range of applications. In this study, based on K-BKZ nonlinear viscoelastic model, thermoforming process analysis was performed for an interior room-lamp. The predicted thickness was minimum at the corner of a molded film, and maximum at the center of the bottom. By using the Taguchi method of design of experiments, the effects of process conditions on residual stresses were investigated. The dominant factors were the liner thickness and the film heating time. As the thickness of the liner increased, the residual stress decreased. And it was found that the residual stress decreased significantly when the film heating temperature was higher than the glass transition temperature. A thermoforming mold and a trimming mold were manufactured, and the spring back was investigated through experiments. The dominant factors were film heating time, liner thickness, and lower mold temperature. As the film heating time and liner thickness increased, the spring back decreased. In addition, it was found that the spring back decreased as the lower mold temperature increased.

Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems

  • Teng Ma;Tiwu Peng;Yang Lin;Mindi Zhang;Guanghui Ren
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.145-154
    • /
    • 2023
  • PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems. MATERIALS AND METHODS. A full-arch preparation digital model was set up with three internal designs, including solid, hollow, and grid. These were printed using three different resin printers with nine models in each group. After scanning, each data was imported into the 3D data processing software together with the master cast, aligned and trimmed, and then put into the 3D data analysis software again to compare the overall and marginal deviation whose results are expressed using root mean square values and color maps. To evaluate the trueness of the resin model, the test data and reference data were compared, and the precision was evaluated by comparing the test data sets. Color maps were observed for qualitative analysis. Data were statistically analyzed by one-way analysis of variance and Bonferroni method was used for post hoc comparison (α = .05). RESULTS. The influence of different internal structures on the accuracy of 3D printed resin models varied significantly (P < .05). Solid and grid models showed better accuracy, while the hollow model exhibited poor accuracy. The color maps show that the resin models have a tendency to shrink inwards. CONCLUSION. The internal structure design influences the accuracy of the 3D printing model, and the effect varies in different printing systems. Irrespective of the kind of printing system, the printing accuracy of hollow model was observed to be worse than those of solid and grid models.

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

The Effective Reduction Method of Unstable Zygomatic Arch Fracture with Thermo-Splint (Thermo-splint를 이용한 불안정한 관골궁골절에 대한 효과적인 고정방법)

  • Kim, Sun Heum;Lee, Soo Hyang;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Song, Wu Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.110-115
    • /
    • 2008
  • Purpose: The objective of this study is to propose an effective management of unstable zygomatic arch fracture. The reduction methods of arch fracture were relatively simple but the maintenance of reduction state is very troublesome. On this, authors introduce an effective management method of unstable zygomatic arch fracture. Methods: Authors experienced 23 cases of unstable segmental zygomatic arch fractures and used Thermo-splint in all cases. All the arch fractures were reduced through Gillies' approach under the general anesthesia. After the reduction, the most effective suspension points were marked on the covering skin of the fractured arch. A needle of heavy nonabsorbable suture material was inserted toward the marking site under the reduced zygomatic arch. And then Therm-splint was dipped in the hot water, and we got the splint pattern of patient face. Reshaped Thermo-splint was trimmed and fixated with previous suspension suture materials. More additive suspension was done if necessary. The splint was applied for in two to three weeks postoperatively. Results: In all the cases, good cosmetic and functional results were observed without severe complications. There were 4 cases of incomplete reductions but they also had no specific problems. There were no facial nerve symptom and scar(stitch mark). Postoperative slight tenderness and trismus were completely subsided after removal of the splint. Conclusion: The Thermo-splint safely protect and maintain the postoperative reduction state. The application, maintenance and removal were easy and simple. It could be reformed to any contour of face and had enough rigidity for supporting. Above all these things, effective prevention of displacement and easy manipulation were significant merit. Authors experienced good results with Thermo-splint, and would introduce it for another method of management of zygomatic arch fracture.

A Collaborative Filtering-based Recommendation System with Relative Classification and Estimation Revision based on Time (상대적 분류 방법과 시간에 따른 평가값 보정을 적용한 협력적 필터링 기반 추천 시스템)

  • Lee, Se-Il;Lee, Sang-Yong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.2
    • /
    • pp.189-194
    • /
    • 2010
  • In the recommendation system that recommends services to a specific user by using the estimation value of other users for users' recommendation service, collaborative filtering methods are widely used. But such recommendation systems have problems that exact classification is not possible because a specific user is classified to already classified group in the course of clustering and inexact result can be recommended in case of big errors in users' estimation values. In this paper, in order to increase estimation accuracy, the researchers suggest a recommendation system that applies collaborative filtering after reclassifying on the basis of a specific user's classification items and then finding and correcting the estimation values of the users beyond the critical value of time. This system uses a method where a specific user is not classified to already classified group in the course of clustering but a group is reorganized on the basis of the specific user. In addition, the researchers correct estimation information by cutting off the subordinate 10% from the trimmed mean of samples and then applies weight over time to the remaining data. As the result of an experiment, the suggested method demonstrated about 14.9%'s more accurate estimation result in case of using MAE than general collaborative filtering method.

Storage stability of dry-aged beef: the effects of the packaging method and storage temperature

  • Choe, Juhui;Kim, Kwan Tae;Lee, Hyun Jung;Oh, Jungmin;Kim, Hyun Cheol;Park, Bumjin;Choi, Yang Il;Jo, Cheorun
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.2
    • /
    • pp.211-218
    • /
    • 2018
  • Different packaging methods and storage temperatures were tested to determine the storage stability of beef dry-aged for 21 days based on microbial, physicochemical, and sensory qualities. After completion of the dry aging, the dried surface of beef sirloin was trimmed off, and the beef was packaged using two different methods (oxygen-permeable wrap or vacuum packaging) and stored at different temperatures ($3{\pm}2^{\circ}C$ or $-23{\pm}2^{\circ}C$) for 0, 7, 14, or 21 days. Lipid oxidation and the sensory quality of the dry-aged beef were not affected by the packaging method and storage temperature during storage. No microbial growth was observed over the storage period in the vacuum-packaged dry-aged beef, regardless of the storage temperature. However, dry-aged beef in the oxygen-permeable wrap packaging showed microbial spoilage with 8.82 log CFU / g at day 7 of the refrigerated storage. The vacuum-packaged dry-aged beef showed the lowest values (p < 0.05) in $a^*$ and chroma at days 14 and 21 at $3^{\circ}C$, and days 7 and 14 at $-23^{\circ}C$, respectively. Therefore, it is recommended that dry-aged beef with wrap packaging stored in refrigerated conditions should be consumed as quickly as possible due to microbial growth. For long-term storage, dry-aged beef should be frozen because freezing can extend the color stability up to day 21 of storage without adverse effects on the hygienic or meat quality aspects of dry-aged beef.

Computed tomography investigation of the three-dimensional structure and production method of White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (CT 조사를 통한 청화백자투각연당 초팔괘문연적의 3차원적 구조와 제작방법에 대한 고찰)

  • Na, Ahyoung;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.1-8
    • /
    • 2021
  • This study investigated White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (hereinafter, the "water dropper") in the collection of the National Museum of Korea using computed tomography (CT). A replica was produced to examine both the structure and its original production method. The CT scanning identified no joint lines or pores in the clay, which suggests that the body (the lower part of the water dropper) was shaped in a single piece using a mold and was then matched with a mold-formed lid (the upper part of the water dropper). The inner container of the body portion was roughly trimmed with a bamboo knife so that its upper surface could be securely attached to the bottom of the lid and prevent any leakage in the joined surface. It appears that the inner container for storing water was made first in a cylindrical shape that met the unit of quantity used at the time and could be easily formed by molding. It was transformed into a trapezoid shape during the process of combining it with the lid. A cylindrical inner container was reproduced using silicon 3D printing to compare its capacity with that of the original inner container. The comparison revealed that the reproduced container had a capacity of 152.5㎖, whereas the original container holds approximately 168.6㎖, a figure similar to three hop (around 174㎖) in Joseon-period units of quantity. Since the capacity of the cylindrical inner container corresponds to a known measure from the late Joseon dynasty, it is likely that the water dropper was originally produced to contain a cylindrical inner container.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.