• 제목/요약/키워드: Triggering sensitivity

검색결과 16건 처리시간 0.024초

Development of a Sensitive Bioassay Method for Quorum Sensing Inhibitor Screening Using a Recombinant Agrobacterium tumefaciens

  • Kim Yeon Hee;Kim Young Hee;Kim Jung Sun;Park Sunghoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권4호
    • /
    • pp.322-328
    • /
    • 2005
  • Acylhomoserine lactones (AHLs) are known to be the triggering molecules in the quorum sensing mechanism of many gram-negative bacteria. In order to detect AHL inhibitors that are potential biofilm inhibitors, a convenient and sensitive bioassay was developed based on the $\beta$-galactosidase activity ($\beta$-GAL) of a recombinant Agrobacterium tumefaciens strain. A series of commercially available AHLs were tested for inducing $\beta$-GAL at varying concentrations in agar-plate and liquid cultures of the reporter strain. All AHLs tested exhibited a concentration­dependent induction, and octanoyl homoserine lactone (OHL) showed the highest sensitivity with a detection limit of 0.1 nM in the liquid culture assay. When fimbrolide, a known quorum sensing inhibitor, was added, induction of $\beta$-GAL by OHL was repressed. The repression at a constant OHL concentration was dependent on the fimbrolide concentration with the detection limit below 1 ppm, indicating that this assay is a sensitive method for screening AHL inhibitors.

Aggregation-Induced Emission (AIE) 기반의 Turn-On 형광센서를 이용한 수질 속 중금속 납 이온의 효율적인 검출 (Efficient Detection of Heavy Metal Lead Ions in Aqueous Media using Aggregation-Induced Emission (AIE)-based Turn-on Fluorescence Sensor)

  • 최해민;성현정;차주연;이성호
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.757-765
    • /
    • 2023
  • Lead, a heavy metal widely employed in various industries, continues to pose a threat to both human health and the environment. Therefore, the development of a sensor capable of rapidly and accurately detecting lead(II) ions in real-time at contaminated sites is crucial. In this study, we have engineered a fluorescent sensor with the ability to efficiently detect lead(II) ions under actual environmental conditions, including tap water and freshwater. The compound, tetraphenylethylene carboxylic acid derivative (TPE-COOH), exhibits high selectivity and sensitivity toward lead(II) ions in aqueous solution, where the interaction between TPE-COOH and lead(II) ions leads to its aggregation, thus triggering a fluorescence "turn-on" based on the aggregation-induced emission (AIE) mechanism. Impressively, compound TPE-COOH proficiently detects lead(II) ions within a range of 30 to 100 𝜇M in tap water and freshwater, even in the presence of various interfering substances.

Environment of radio-sources over 8 decades of radio luminosity

  • Karouzos, Marios;Im, Myungshin;Kim, Jae Woo;Lee, Seong Kook;Chapman, Scott
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.41.1-41.1
    • /
    • 2014
  • Although the link between activity in the nuclei of galaxy and galactic mergers has been under scrutiny for several years, it is still unclear to what extent and for which populations of active galaxies merger-triggered activity is relevant. The environment of AGN allows an indirect probe of the past merger history and future merger probability of these systems, suffering less from sensitivity issues while extending to higher redshifts, compared to traditional morphological studies of AGN host galaxies. Here we present results from our investigation of the environment of radio selected sources out to redshift z=2. We employ the first data release J-band catalog from the new near-IR Infrared Medium-Deep Survey (IMS) and 1.4 GHz radio data from the Faint Images of the Radio Sky at Twenty-cm (FIRST) survey and a deep dedicated VLA survey of the VIMOS field, covering a combined total of ~20 sq. degrees. Given the flux limit of the combined radio catalog (0.1 mJy), we probe a radio luminosity range of 10^36-10^44 erg/s. Using the second and fifth closest neighbor density parameters, we test whether active galaxies inhabit denser environments and study these overdensities in terms of both distance to the AGN and its luminosity. We find evidence for a sub-population of radio-selected AGN that resides in significantly overdense environments at small scales, although we do not find significant overdensities for the bulk of our sample. We do not recover any dependence between the AGN radio-luminosity and overdensities. We show that radio-AGN inhabiting the most underdense environments in the field have vigorous ongoing star formation. We interpret these results in terms of the triggering and fuelling mechanism of radio-AGN.

  • PDF

충격 전달에 의한 Gap Test의 폭굉 반응 해석 (A Study on Shock-induced Detonation in Gap Test)

  • 김보훈;강원규;장승교;박정수;여재익
    • 한국추진공학회지
    • /
    • 제20권2호
    • /
    • pp.75-85
    • /
    • 2016
  • 감쇠기를 사이에 두고 여폭약과 수폭약으로 충전된 파이로 착화기는 격벽의 압력 감쇠 현상과 고에너지 물질의 충격 점화 특성을 갖는다. 고폭약의 폭굉 반응 및 비반응 물질 통과에의 폭압 감쇠와 더불어 격벽의 형상 변화를 모사하기 위해서는 충격 전달에 의한 gap test의 폭굉 모델링이 필요하다. 본 연구에서는 오일러리안 레벨셋 기법이 적용된 다중물질 하이드로 코드를 사용하여 pentolite 작약과 열폭압 RDX의 폭발 반응 및 PMMA gap을 통과하는 충격파 전달을 해석함으로써 화약-격벽간 상호작용 및 임계 두께, 음향 임피던스, go/no-go 기폭 점화에 대한 특성을 정량화하였다.

NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰 (Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube)

  • 최용;김종호;김준영;임기천;김상은;최연성;이경한;주관식;김병태
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.82-93
    • /
    • 2000
  • 목적: 이 논문에서는 본 연구진이 개발한 소형 감마카메라 시스템에서 사용한 NaI(Tl)섬광결정-위치민감형 광전자증배관 검출기와 각 전자회로에서의 입 출력 신호특성을 조사하고, 시스템 개발을 위해 각 전자회로에서 결정한 변수들에 대하여 고찰하고자 한다. 대상 및 방법: 크기가 $60{\times}60{\times}6mm^3$인 NaI(Tl) 섬광결정을 위치민감형 광전자증배관에 접합하고, 저항 회로와 전치증폭기, 여러 가지 전자회로, 아날로그-디지털 변환기 그리고 개인용 컴퓨터를 이용하여 소형 감마카메라 시스템을 개발하였다. 섬광결정에서 검출된 신호들을 위치민감형 광전자증배관을 통하여 증폭한 후, 전하분할방법으로 34개의 교차된 양극채널 신호를 4개($X^+,\;X^-,\;Y^+,\;Y^-$) 위치신호로 출력시켰다. 출력된 신호를 전치증폭기와 층폭기를 사용하여 증폭 정형하였으며, 핵기기 모듈(nuclear instrument modules, NIMs)을 이용하여 위치신호와 트리거 신호를 처리하였고, 각 단계에서 신호특성을 분석 고찰하였다. 이 신호들을 아날로그-디지털 변환기와 앵거로직을 사용하여 처리한 후, 일반 개인용 컴퓨터에서 그래픽 프로그램을 이용하여 감마카메라 영상을 구현하였다. 결과: 연구에서 분석 고찰한 신호특성을 그림을 통하여 나타내었으며, 이러한 신호처리를 이용하여 개발한 감마카메라는 약 $8{\times}10^3$ counts/sec/${\mu}Ci$의 계수율을 보였다. 140 keV에 대하여 18% FWHM의 에너지 분해능과 X, Y 방향으로 각각 2.2, 2.3 mm FWHM의 내인성 위치 분해능을 나타내었다. 또한 평행구멍형 조준기를 장착한 상태에서 유방모형에 위치한 $2{\sim}7mm$ 직경의 방사능 분포를 정확하게 영상화할 수 있었다. 결론: 이 연구에서 개발한 소형 감마카메라 시스템을 구성하고 있는 각 전자회로에서 결정한 매개변수와 신호특성 고찰결과를 나타내었다. 이 신호처리 시스템 분석을 통하여 감마선 검출을 이용한 영상표현 기술을 확보할 수 있었으며, 소형 감마카메라 개발을 위한 간단한 신호처리 방법을 고안하여 제시하였다.

  • PDF

NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발 (Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging)

  • 김종호;최용;권홍성;김희중;김상은;최연성;이경한;김문회;주관식;김병태
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.365-373
    • /
    • 1998
  • 목적: 일반 감마카메라는 그 크기(${\sim}500mm$ 폭)가 전신영상 획득에 적합하도록 설계되어있어 유방영상 획득에는 비 이상적이다. 이 연구의 목적은 물리적 영상 저하요인인 배후 방사능과 광자감쇠 효과를 최소화하여 높은 공간분해능과 시스템 민감도를 가지며 유방영상에 적합하도록 소형화된 저가-고성능유방암 진단전용 소형 감마카메라 개발이다. 대상 및 방법: 크기가 $60 mm{\times}60 mm{\times}6 mm$인 NaI(T1) 섬광결정을 위치민감형 광전자증배관에 접합시켜 감마선 측정신호인 $X^+,\;X^-,\;Y^+,\;Y^-$를 얻은 다음, 증폭기 등을 포함한 전자회로(nuclear instrument modules, NIM)를 통하여 검출기로부터 발생하는 위치신호와 트리거 신호를 처리하였다. 이 신호들을 아날로그-디지털 변환기와 앵거로직을 사용하여 분석한 후 감마카메라 영상을 구성하여 일반 개인용컴퓨터에 표현하는 시스템을 개발하였다. 개발된 감마카메라의 1차적인 성능을 평가하기 위해 Tc-99m 점선원을 이용하여 내인성 계수율과 플러드 영상을 획득하였다. 또한 일정간격의 구멍이 있는 구멍 마스크와 직경 2, 3, 4, 5, 6, 7 mm 크기의 구모양에 방사능 용액을 채울 수 있는 유방모형을 제작하여 평행구멍형조준기를 장착하고 영상을 획득하였다. 결과: 개발된 감마카메라는 약 $8{\times}10^3 counts/sec/{\mu}Ci$의 계수율을 보였으며, 공간왜곡은 관찰되나 양질의 플러드 영상과 구멍 마스크 영상을 획득할 수 있었고, 유방모형에 위치한 방사능 분포를 정확하게 영상화할 수 있을 뿐 아니라 최소 2 mm의 방사능 위치를 판별할 수 있는 영상을 획득하였다. 결론: NaI(T1)-위치민감형 광전자증배관를 이용하여 유방영상에 적합한 소형감마카메라를 개발하였다. 추후 선형성, 장균일도 및 불응시간에 대한 보정 알고리즘을 완성하여 적용하고, 정상작동 여부를 검사하기 위한 정도관리 방법을 설정하면, 유방 신티그라피의 정확도를 높이는데 기여할 것이다.

  • PDF