• Title/Summary/Keyword: Trifluoro-acylation

Search Result 4, Processing Time 0.018 seconds

Chiral Separation of Derivatized Racemic Alcohols on Substitued Cyclodextrin Stationary Phases by Capillary Gas Chromatography (모세관 기체 크로마토그래피에 의한 치환된 Cyclodextrin 정지상을 이용한 알코올 유도체의 키랄분리)

  • Lee, Sun-Haing;Seo, Yeong-Ju;Lee, Kwang-Pill
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.94-102
    • /
    • 1995
  • S-Hydroxypropyl(PH) ${\beta}$-cyclodextrin(hydrophilic), dialkyl(DA)-cyclodextrin(hydrophobic), trifluoroacetyl(TA) ${\gamma}$-cyclodextrin(intermediate) stationary phases were used for gas chromatographic separation of racemic alcohols and their derivatives. All the alcohols used for this experiment were derivatived by using trifluoro acetic anhydride, acetic anhydride, or trichloro acetic anhydride. It is apparent that the enantioselectivity of the enantiomeric pairs was very dependent on the type of acylation reagent. The best experimental condition of optical resolution of the alcohols and their derivatives was different on the polarity of the solute molecules. The chiral separation was also studied depending on temperature, polarity of the column, and hydrogen bonding ability and steric effect between the alchols and CD stationary phase. The chiral recognition mechanism is dependent not upon the kinds of the chiral stationay phases but upon the derivatization of the racemic alchols.

  • PDF

Comparison of the Analytical Method for 3-Monochloropropane-l,2-diol in Food (식품 중 3-monochloropropane-1,2-diol의 분석법 비교 연구)

  • Yoo, Seung-Seok;Oh, Chang-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.360-365
    • /
    • 2007
  • The studies for the derivatization of 3-monochloropropane-1,2-diol (3-MCPD) were performed mainly as acylation with HFBI (heptafluorobutyrylimidazole), alkylation with PBA (phenylboric acid) and silylation with BSTFA (N,O-bis[trimethylsilyl]trifluoroacetamide). Also silylation with MTBSTFA(N-methyl-N-[tert.-butyldimethylsilyl] trifluoroacetamide) and acylation with MBTFA (N-Methyl-bis[trifluoro-acetamide]) were also considered. Except the TBDMS derivative of 3-MCPD, all the derivatives were detected well. The derivatives of 3-MCPD with HFBI, PBA and BSTFA showed below 10 ${\mu}g/kg$ which was sensitive enough to satisfy Korea maximum residue limit 0.3 mg/kg. Among the tested adsorbents, Extrelut20 and Florisil were evaluated as the proper adsorbents to eliminate the soy sauce matrix for 3-MCPD. Ethyl acetate was the most efficient eluent with good recovery rate. The desired surrogate compound and internal standard were 1,2-butanediol and 1,2-dibromo-3-chloropropane, respectively. The limit of detection for PB-MCPD and TMS-MCPD were 10.16 and 7.06 ${\mu}g/kg$ on GC/MSD, respectively. HFB-MCPD derivative showed the lowest detection limits 2.98 and 5.32 ${\mu}g/kg$ by GC/ECD and GC/MSD, respectively.

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.