• Title/Summary/Keyword: Tricuspid valve, replacement

Search Result 141, Processing Time 0.026 seconds

Surgical treatment of Ebstein`s Anomaly-Report of 6 cases- (Ebstein 기형의 외과적 치료-6례 보고-)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.506-511
    • /
    • 1987
  • Increased clinical interest, stimulated by newer diagnostic techniques, has made it apparent that Ebstein`s anomaly represents a spectrum of right heart abnormalities. In the usual case, the septal and posterior leaflets of the tricuspid valve are not attached to the true annulus, but are displaced distally into the ventricle. Also the degree of malattachment and the structural deformities of the cusps may vary greatly. Recently we experienced 6 cases of Ebstein`s anomaly who underwent corrective operation in our hospital. Five patients were operated by plication and annuloplasty techniques based on the construction of a monocusp valve by the use of the anterior leaflet. Remained one was operated on by tricuspid valve replacement using No 31 mm C-E tissue valve. There was no operative mortality and the postoperative courses were relatively good with marked symptom improvement.

  • PDF

Clinical Experience of Multiple Valve Replacement (다중판막치환술에 대한 임상적 연구)

  • 조창훈
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1346-1353
    • /
    • 1992
  • From Febrary 1984 to July 1992, 138 cases of multiple valve replacements were performed at the Department of Thoracic and Cardiovascular Surgery, Dongsan Medical Center, Keimyung University. There were 81 females and 57 males, and their ages ranged from 19 to 60 years [mean age, 40.1$\pm$10.9 years]. Thirteen of these patients had undergone previous cardiovascular procedures, with an average of 76.3 months between procedures[range, 3 to 180 months]. Mitral and aortic valve replacement were done in 135 patients, 2 underwent triple valve replacement and 1 underwent mitral and tricuspid valve replacement. Associated procedures were necessary in 20 patients[14.5%]. The operative mortality was 5.8% and the most common cause was low cardiac output. Late follow-up of 83% has been accomplished in 130 early survivors, with a late mortality of 5.9%. The late mortality was due to valve thrombosis in 2 patients, cerebral infarction in 1, heart failure in 1, arrhythmia in 1, and bleeding in l. Of those patients who survived, New York Heart Association functional class improved significantly[from 70% class III and IV before to 88% class I and II after]. Actuarial survival rate including all deaths was 88.8% at 8 years. The follow-up studies revealed that thromboembolism, reoperation and bleeding rate were 1.2%/patient-year, 0.85% /patient-year and 0.57%/patient-year at 8 years postoperatively. We concluded that valve thrombosis, embolism, and anticoagulant-related hemorrhage were the main risk factors of longterm survival of patients.

  • PDF

Short-term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis (St. Jude 기계판막의 단기및 중기 성적)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • St.Jude Medical cardiac valve replacement was performed in 322 patients: 191 had mitral, 58 had aortic, 72 had double valve and 3 had tricuspid valve replacement. Motality rate in early period was 2.8%[9 patients]. The most common cause of early death was low cardic output syndrome. Follow up extended from 1 to 90 months[mean: 34 months] in 292 patients among 313 in all surviving patients [93.6%]. There were thrombolic complications in eighteen patients. The probability of free from thromboembolism at 5 yerars in MVR, AVR and DVR were 84.7%, 91.8% and 90.2% respectively. And also, actuarial event free rate at 5 years in MVR, AVR and DVR were 80.1%, 82.2%, and 81.4% respectively. There were fourteen late death during follow up period: six from thromboembolism, one from hemorrhage and the others from non valve related -or unknown complications. The acturial survival rate at 5 years were 93.1% in mitral, 92.1% in aortic and 97.1% in double valve replacement. In conclusion, the performance of the St. Jude Mecanical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

Early and Mid-term Results for Repair of Ebstein's Anomaly (엡스타인 기형에 대한 수술적 치료의 조기 및 중기 결과)

  • Lee Chang-Ha;Hwang Seong Wook;Lim Hong Gook;Kim Woong-Han;Kim Chong Whan;Lee Cheul
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.284-290
    • /
    • 2005
  • We evaluated the early and mid-term results for repair of Ebstein's anomaly. Material and Method: Between January 1989 and June 2004, 29 patients underwent repair of Ebstein's anomaly. The median age was 11.4 years (4 days-50 years). Tricuspid insufficiency equal to or greater than grade 3 was present in 21 $(72.4\%)$ patients. Surgical techniques included tricuspid valve repair with vertical plication of the atrialized ventricle (n=14), Carpentier's technique (n=7), tricuspid valve replacement (n=4), systemic-to-pulmonary arterial shunt (n=2), tricuspid valve repair (n=1), and Fontan operation (n=1). Bi-directional cavopulmonary shunt (BCPS) was required in 5 patients. Among the 2 neonates, one patient underwent successful biventricular repair, and the other patient underwent systemic-to-pulmonary arterial shunt. Follow-up was possible in 21 patients $(75\%)$, and the average follow-up was 37.6 months (3 months-11.3 years). Result: There were $1(3.4\%)$ early and 1 late deaths. Reoperation was required in 4 patients. Two patients underwent tricuspid valve re-replacement, and the other 2 tricuspid valve repair. At recent follow-up, only 2 patients showed tricuspid insufficiency equal to or greater than grade 3, and most patients showed clinical improvement. Excluding the patients who underwent tricuspid valve replacement, the actuarial rate of freedom from reoperation at 1 and 5 years were $94.7\%\;and\;79.0\%$, respectively. Conclusion: Tricuspid valve repair was possible in most patients with good mid-term outcome. Most patients showed clinical and hemodynamic improvement. Indications for the BCPS should be clarified.

Open heart surgery of Ebstein's anomaly -Report of 12 cases- (Ebstein 기형에 대한 개심술 -12례 보고-)

  • Ahn, Hyuk;Park, Yee-Tae;Rho, Joon-Ryang;Suh, Kyung-Phill;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.157-163
    • /
    • 1983
  • Ebstein's anomaly is a rare congenital cardiac malformation oand the ideal surgical correction seems controversial at present, and some problems are left unsolved in the surgical correction of this anomaly. Between June 1978 and June 1982, 12 patients with Ebsteins' anomaly underwent corrective open heart surgery at Seoul National University Hospital. Except for one patient, who had no ASD, all had a huge right atrium, secundum type ASD, and definite atrialized right ventricle. Typically, displaced tricuspid valve leaflets were found in all cases, but the degree of displacement and deformity were variable. In the point of NYHA functional classification, five were in class II, six were in class III, and one was in class IV. Ten patients were operated on by tricuspid valve replacement and pication. Two patients were operated on only by plication and annuloplasty techniques, and in all cases, ASD was closed. Postoperatively, four patients suffered from complete A-V block, and two of them died immediately. The remaining two patients took pacemaker generator implantation with good results. The other eight patients were in good condition. Tricuspid valve replacement using tissue valve and plication of the atrialized rght ventricle seems to be a good method of surgical correction for Ebstein's anomaly.

  • PDF

Surgical Correction of Ebstein's Anomaly -11 cases- (Ebstein 기형의 외과적 치료 - 11례 -)

  • 이선희;김시훈;윤정섭;김치경;조건현;왕영필;곽문섭;김우찬
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1202-1206
    • /
    • 1996
  • Ebstein's anomaly is an unusual and a rare congenital cardiac malformation but characteristic abnormality of the development of the tricuspid valve, right atrium and ventricle. The characteristic findings are a displaced tricuspid valve with a septal leaflet spiralling into the right ventricle. The surgical correction is variable and are left unsolved problem in surgical treatment of anomaly. Between January 1988 & December 1995, we experienced 11 cases of Ebstein's anomaly and associated cardiac anomalies are ASD, PFO, ASD with VSD. The typically displaced tricuspid valve leaflet was found in all cases. In the NYHA functional classification, three were in class II, seven were in class III, and one was in class IV. Nine patients were operated by tricuspid annuloplasty & plication with Danielson's method and two patients were done by tricuspid valve replacement with plication, and in all cases associated anomaly was corrected. Postoperatively, five patients suffered from complication - low cardiac output syndrome, arrhythmia and wound infection. There was no operative mortality and the postoperative courses were relatively good conditions with more improvement of symptoms.

  • PDF

Clinical Analysis of St. Jude Medical Valve Replacement (St. Jude Medical 기계판의 임상적 연구)

  • 손영상
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.960-969
    • /
    • 1989
  • Results of St. Jude Medical valve replacement are presented in 171 patients who underwent operation from January 1983 through June 1989. The patients were 79 males and 92 females with ages ranging from 12 to 71 years. Total 211 of St. Jude Medical valves were implanted: 148 in mitral position, 57 in aortic position, 6 in tricuspid position. The follow-up was from 2 to 76 months with a cumulative period of 375 patient-year. The actuarial survival at 1 year, 3 year and 5 year were 92.1 %, 87.6 % and 86.3% respectively. The linearlized incidences of valve failure, thromboembolism, thrombotic obstruction, anticoagulation related hemorrhage and all valve related complication were as follows: 0.5 %/pt-yr, 0.5 %/pt-yr, 0.5 %/pt-yr, 1.1 %/pt-yr, and 2.4 %/pt-yr, respectively. The performance of the St. Jude Medical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prostheses such as thromboembolism and thrombotic obstruction.

  • PDF

Clinical Analysis of Bileaflet Mechanical Valve Replacement (Bileaflet Mechanical Valve의 임상적 고찰)

  • Kim, Mun-Hwan;Jin, Seong-Hun
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.677-685
    • /
    • 1993
  • Experience with bileaflet mechanical valve replacement at the Inha Hospital in 192 patients, operated on from June 1986 until April 1993. Two hundred fourty-one prostheses [51 Duromedics, 79 St.Jude Medical, and 111 CafboMedics]were implanted during the total 195 operations. Mitral valve replacment[MVR]was done in 113 cases, aortic valve replacement[AVR]in 34, tricuspid valve replacement[TVR]in 2, and double valve replacement[DVR]in 46 cases.Of the total patients, 63.0% were women and 37.0% were men. The mean age of the patients was 40.8 years, ranged from 14 to 67years. Overall early mortality was 9.2\ulcorner%[18 out of 195]; 9.7%[11 out of 113]for MVR, 14,7% [5 out of 34]for AVR, and 4.3%[2 out of 46]for DVR. All of the operative survors were followed over a period of one to 83 months with a mean of 37 months, for total 543 patient-years. So far, eleven patients[6.7% of the long-term survivors]were lost to follov-up after a mean postoperative follow-up of 22.8 months. There were nine late deaths; three deaths due to prostetic valve endocarditis, two due to persistent heart failure, one due to cerebral hemorrhage, one due to aortic dissection after Bentall oreration, and two sudden deaths. Actuarial survival rate at 6.9 years was 94.8%, There were seventeen valve-related complications; three prosthetic valve thromboses, three thrombembolisms, three instances of prosthetic valve endocarditis, two paravalvular leakages, and six hemorrhagic complications related to anticoagulation. The actuarial rate of freedom from all valve-related complications at 6.9years was 91.3%. There were significant decreases in the heart size postoperatively that can be demonstrated by comparison of cardio-thoracic ratios on simple chest X-ray and left ventricle dimensions on echocardiography. We conclude that this midterm follow-up shows good results in terms of hemodynamics and durability although further long-term evaluations are mandatory.

  • PDF

Triple Valve Replacement -A report of two cases- (삼판막 이식수술 (2례 보고))

  • 박표원
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.100-104
    • /
    • 1980
  • Simultaneous triple valve replacements were performed in two patients on January and April 1980 at Seoul National University Hospital. The first case was 17 years old male patient with a history of exertional dyspnea for 7 years. He was in class III by the NYHA functional classification and diagnosed as aortic insufficiency, mitral steno-insufficiency and tricuspid insufficiency. The second case was 46 years old male patient suffered from exertional dyspnea for 5 years, He was in class IV and diagnosed as aortic stenoinsufficiency, mitral stenoinsufficiency and tricuspid insufficiency. Triple valve replacements were performed under the deep hypothermia and pharmacologic cardiac arrest with aortic cross clamping for 80 minutes to 159 minutes. Total extracorporeal circulation time were 197 and 176 minutes respectively. The postoperative courses were uneventful.