• Title/Summary/Keyword: Tricuspid insufficiency

Search Result 69, Processing Time 0.028 seconds

Surgical Treatment of Isolated Primary Tricuspid Insufficiency except Ebstein`s Anomaly - Report of 2 Cases - (Ebstein`s anomaly 이외의 격리성 원발성 삼천판 부전증[isolated primary tricuspid insufficiency]의 수술 치험 2례)

  • Baik, Hee-Jong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.24 no.9
    • /
    • pp.907-912
    • /
    • 1991
  • Isolated primary tricuspid insufficiency except Ebstein`s anomaly is rare disease. Recently we experienced two cases of isolated primary tricuspid insufficiency and treated successfully with annuloplasty or valve replacement. We could not classify our case as one of the classification of isolated tricuspid insufficiency, because the morphology and microscopic finding did not suggest any similar variety.

  • PDF

Tricuspid Valve Insufficiency due to Intracardiac Migration of a Stent Inserted into Rt. Subclavian Vein to the Right Ventricle after the Treatment of Central Venous Stenosis (중심정맥 협착 환자에서 우측 쇄골하정맥에 삽입한 스텐트의 우심실 이동으로 인한 삼첨판막 폐쇄부전 치험)

  • Cho, Seong-Ho;Cho, Sung-Rae;Park, Eok-Sung;Kim, Jong-In
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.739-742
    • /
    • 2010
  • Two stents were placed across the right subclavian vein due to stenosis of the right subclavian vein in a 40-year-old patient with chronic renal failure on hemodialysis. During the follow up period, one of stents migrated into the right ventricle inducing tricuspid valve insufficiency. Percutaneous stent removal had failed and the stent was removed by open heart surgery with Tricuspid valve repair with a good result, and then we report the case.

Tricuspid Valve Repair for Tricuspid Valve Insufficiency Following a Cardiac Stab Injury - One case report - (심장 자상 후에 발생된 삼첨판막 폐쇄부전의 삼첨판막 성형술 - 1예 보고 -)

  • Kim, Dong-Hyun;Lee, Seong-Jin;Lee, Chol-Sae;Lee, Kihl-Rho;Lee, Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.376-379
    • /
    • 2007
  • A 51-year-old male was admitted three month previously with a cardiac stab injury and he underwent direct cardiac repair He had no problem after this event. He complained of dyspnea that stalled 2 months after the original injury. Echocardiography showed severe tricuspid regurgitation and so, chordac replacement and ring annuloplasty was performed. Herein we report on a case of tricuspid valve repair for treating tricuspid insufficiency following a cardiac stab injury.

Triple Valve Replacement -A report of two cases- (삼판막 이식수술 (2례 보고))

  • 박표원
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.100-104
    • /
    • 1980
  • Simultaneous triple valve replacements were performed in two patients on January and April 1980 at Seoul National University Hospital. The first case was 17 years old male patient with a history of exertional dyspnea for 7 years. He was in class III by the NYHA functional classification and diagnosed as aortic insufficiency, mitral steno-insufficiency and tricuspid insufficiency. The second case was 46 years old male patient suffered from exertional dyspnea for 5 years, He was in class IV and diagnosed as aortic stenoinsufficiency, mitral stenoinsufficiency and tricuspid insufficiency. Triple valve replacements were performed under the deep hypothermia and pharmacologic cardiac arrest with aortic cross clamping for 80 minutes to 159 minutes. Total extracorporeal circulation time were 197 and 176 minutes respectively. The postoperative courses were uneventful.

  • PDF

Tricuspid Valve Insufficiency Complicating Tetralogy Of Fallot (삼첨판막폐쇄부전증을 동반한 활로씨 4 증후군[1예 보고])

  • 조대윤
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.229-232
    • /
    • 1980
  • Approximately 5 percent of infective endocarditis are limited to the right side of the heart, the tricuspid valve being the usual site of involvement. Usually there is no underlying cardiac disease, and the vegetations occur on previously normal tricuspid leaflets. This paper reports a case of bacterial endocarditis involving the bio-tricuspid valve in a patient with tetralogy of Fallot, and who required prosthetic valve replacement in addition to surgical therapy for the congenital lesions.

  • PDF

Severe Tricuspid Insufficiency after Correction of Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery(ALCAPA) (ALCAPA 교정후 발생한 심한 삼첨판 폐쇄부전)

  • 백만종;김웅한;오삼세;류재욱;공준혁
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.724-728
    • /
    • 2001
  • We report a case of an 8 years and 11 month-old male patient who had developed severe tricuspid insufficiency(TI) after correction of anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA). Transthoracic echocardiogram and coronary angiography confirmed ALCAPA, ischemic mitral regurgitation and trivial TI. He underwent direct reimplantation of the left coronary artery to the aortic root by using additional cannulation at the main pulmonary artery for arterial inflow and cardioplegia delivery to the left coronary artery. After the correction of ALCAPA, transesophageal echocardiogram(TEE) revealed good antegrade flow at the aortic implantation site of the left coronary artery and severe TI(Gr III-IV/IV). Cardiopulmonary bypass was reestablished and tricuspid valve was repaired with Kay-type annuloplasty, artificial chordae formation and chordal shortening plasty. The postrepair TEE revealed trivial to mild TI.

  • PDF

Permanent Pacemaker Lead Induced Severe Tricuspid Regurgitation in Patient Undergoing Multiple Valve Surgery

  • Lee, Jung Hee;Kim, Tae Ho;Kim, Wook Sung
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.129-133
    • /
    • 2015
  • Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

The Effects of Tricuspid Annuloplasty on Funcional Tricuspid Regurgitation (기능적 삼첨판 폐쇄부전증 환자에서 판막륜 성형술의 효과)

  • 유경종
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.829-836
    • /
    • 1995
  • Ninety-one adult patients underwent three different methods of annuloplasty and compared them by the amount of tricuspid regurgitation. Group I [n=17 is Kay method, Group II [n=46 is modified Kay method and Group III [n=28 is De Vega and modified De Vega method. Preoperative and postopeative size of the liver and its function, the cardiothoracic ratio, EKG and echocardiogram were analyzed. The follow up was done for all the patients [mean 20.0$\pm$ 8.5 months . The postoperative size of the liver, the postoperative cardiothoracic ratio and the postoperative systolic pressure of the right ventricle decreased significantly compared to preoperative size, ratio and pressure [p=0.0001, p=0.0001, p=0.0001 . But there were no differences between the groups. The results of annuloplasty revealed that tricuspid regurgitation improved postoperatively [p=0.0001 even though there was no statistically significant differences in relation to the methods of annuloplasty. The right ventricular systolic pressure and the amount of regurgitation decreased significantly during the postoperative period by performing 3 different methods of annuloplasty, although we could not find the differences between the three different methods.

  • PDF

Tricuspid Edge-to-Edge Repair Versus Tricuspid Valve Replacement for Severe Tricuspid Regurgitation

  • Jihoon Kim;Heemoon Lee;Ji-Hyun Jung;Jae Suk Yoo
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.775-786
    • /
    • 2023
  • Background and Objectives: Tricuspid valve (TV) repair techniques other than annuloplasty remain challenging and frequently end in tricuspid valve replacement (TVR) in complicated cases. However, the results of TVR are suboptimal compared with TV repair. This study aimed to evaluate the clinical effectiveness of TV edge-to-edge repair (E2E) compared to TVR for severe tricuspid regurgitation (TR). Methods: We retrospectively reviewed 230 patients with severe TR who underwent E2E (n=139) or TVR (n=91) from 2001 to 2020. Clinical and echocardiographic results were analyzed using inverse probability of treatment weighting analysis and propensity score matching. Results: The two groups showed no significant differences in early mortality and morbidities. During the mean follow-up of 106.2±68.8 months, late severe TR and TV reoperation rates were not significantly different between groups. E2E group, however, showed better outcomes in overall survival (p=0.023), freedom from significant tricuspid stenosis (TS) (trans-tricuspid pressure gradient ≥5 mmHg, p=0.021), and freedom from TV-related events (p<0.001). Matched analysis showed consistent results. Conclusions: E2E for severe TR presented more favorable clinical outcomes than TVR. Our study supports that E2E might be a valuable option in severe TR surgery, avoiding TVR.

Clinical Study of Multiple Cardiac Valve Replacement : A Report of 63 Cases (중복심장판막이식의 임상적 고찰 63예 보고)

  • Suh, Kyung-Pill;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.405-413
    • /
    • 1980
  • A total of 63 patients [42 males and 21 females] underwent multiple valve replacement with artificial valves between January 1975 and August 1980 at Seoul National University Hospital. There were 38 patients with aortic and mitral valve replacement, 22 with mitral and tricuspid, and 3 with aortic, mitral and tricuspid valve replacement. The valve lesions varied from trivial to severe and most aortic and mitral valves had mixed stenosis and insufficiency, while tricuspid valves had only insufficiency. The patients were severely symptomatic in majority of the cases, and belonged to the Classes III and IV [III:45, IV:16] of the NYHA functional criteria. Hemodynamic studies were performed on all the patients. The mean pulmonary wedge pressure was remarkably increased to 19.8 mmHg in aortic and mitral valve lesions and 18.0 mmHg in mitral and tricuspid valve lesions. The mean pulmonary arterial pressure was also increased, while the cardiac index was reduced. In 1977, the average perfusion time was 245.5 minutes for aortic and mitral valve replacement and 181.6 minutes for mitral and tricuspid valve replacement. It has progressively declined to 169.2 minutes for aortic and mitral valve replacement and 123 minutes for mitral and tricuspid valve replacement in 1980. The average period of aortic occlusion also declined after the use of cardioplegic solution. Twenty deaths occurred among the 63 patients operated upon, an overall mortality rate of 30.8%. The operative mortality has declined with successive year from a level of 66.7% before 1977 to 21.1% in 1980. Fourteen patients suffered from a list of postoperative complications, which eventually resolved with adequate treatment. All the survivors were enjoying the levels of daily life activities greater than those existing before the operation.

  • PDF