• Title/Summary/Keyword: Trichloroethylene

Search Result 340, Processing Time 0.027 seconds

Characteristic of Permeability with the Sand, Calcium Bentonite and Solidifier Mixtures according to Selective Reaction of TCE (트리클로로에틸렌(TCE) 선택적 반응에 따른 모래, 칼슘-벤토나이트 및 겔화제 혼합차수물의 투수 특성)

  • Yun, Seong Yeol;Choi, Jeong Woo;Oh, Minah;Lee, Jai-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • To improvement the swelling characteristics of the existing cutoff wall against the moisture, the permeability of the sand, calcium bentonite and solidifier mixture according to the contact with trichloroethylene (TCE) was evaluated. Characteristics analysis and the permeability test of the research materials were performed. The permeability was decreased as the mixing ratio of the calcium bentonite was increased and it was increased as the mixing ratio of the solidifier was increased. In conclusion, when mixing 15% of calcium bentonite and more than 30% of solidifier, the permeability coefficient in the underground water movement was analyzed as more than α × 10-4 cm/sec showing that it does not block the underground water movement. In addition, as the permeability coefficient of mixtures after TCE reaction was analyzed as less than α ×10-7 cm/sec, it satisfied the condition of blocking layer (less than 1.0 × 10-6 cm/sec). Therefore, the calcium bentonite and solidifier can be utilized as barrier that showing the characteristic of percolation ability conversion in soil and underground water contaminated with TCE.

Evaluating the Micronucleus Induction Potential for the Genotoxicity Assay Using the Human Skin Model, KeraSkinTM (인공피부모델 KeraSkinTM을 이용한 유전독성 평가)

  • Lee, Su-Hyon;Jung, Haeng-Sun;Kim, Seol-Yeong;Kim, Hye Soo;Lim, Kyung-Min;Chung, Young-Shin;Choe, Tae-Boo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.3
    • /
    • pp.211-216
    • /
    • 2016
  • Micronucleus test is genotoxicity assay for detection of micronuclei in the cytoplasm of interphase cells. The reduction and replacement of in vivo toxicity testing on animals require the development of in vitro models to predict the genotoxicity or other tests for cosmetic products. In this study, we evaluated a genotoxicity assay for topically applied chemicals using a three-dimensional human reconstructed skin model, KeraSkin$^{TM}$. Two genotoxins, mitomycin C (MMC) and methyl methanesulfonate (MMS), induced significant dose-related increases in cytotoxicity and micronuclei induction in the skin model. In contrast, two non-genotoxins, 4-nitrophenol (4-NP) and trichloroethylene (TCE), induced cytotoxicity but not micronucleus formation. In conclusion, micronucleus test using human skin model may be useful for predicting in vitro genotoxic potentials of cosmetic products.

The study on the measurement of volatile organic compounds in the air of A and B industrial area (모 공단 대기 중 휘발성 유기화합물 측정에 관한 연구)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.130-144
    • /
    • 2004
  • Recently, the air pollution in A and B industrial area has become one of the most important issues, then 60 VOCs in the area were measured using a highly sensitive method. The VOCs were adsorbed onto Carbotrap using air sampler and subsequently desorbed by a thermal desorber system into gas chromatograph-mass spectrometry (TDS-GC-MS). The peaks of all compounds had good chromatographic properties and offered very sensitive response for the EI-MS (SIM). Method detection limits (MDL) ranged from 0.01 to 0.1 ppt(v/v), and linearities of calibration curves were over 0.995. We analyzed total 90 atmosphere air samples of A and B industrial complex using the method. Benzene, toluene, ethylbenzene, xylene, n-hexane, fluorotrichloromethane, carbon tetrachloride, 1,2-dichloroethane, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, styrene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, sec-butylbenzene and naphthalen were identified as the major compounds in the air, and their average concentrations were 0.81, 5.02 1.30, 3.0, 0.81, 37.9, 0.07, 0.15, 0.15, 0.79, 0.06, 0.33, 0.03, 0.12, 0.23, and 0.35 ppb(v/v), respectively. The concentrations of VOCs were low in summer and high in fall or winter. When the concentrations detected in air compare with WHO's norm, no case exceed it.

Volatile Organic Compounds contamination in some urban runoff and groundwater samples in Seoul City (서울시 도로변 빗물과 지하수의 VOCs오염)

  • 이평구;박성원;전치완;신성천
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.73-91
    • /
    • 2001
  • compounds (VOCs) were selected for assessment of VOCs contamination in some urban runoff and groundwater samples in Seoul. They included 3 aromatic hydrocarbons, 13 alkyl benzenes, 1 ether, 26 halogenated alkanes, 10 halogenated alkenes, and 9 halogenated aromatics. The levels of VOCs in urban runoff and groundwater were measured for samples collected in March 2000, June 2000 and November 2000 in Seoul City. A total of 78 samples (44 run-off water, 27 groundwater, and 7 samples from 4 urban wastewater treatment plants in Seoul) were collected and analysed by GC-MS with purge and trap. After examination of the runoff, it was concluded that alkyl benzenes and aromatic hydrocarbons were organic compounds which were significantly impacted by traffic flows in Seoul. Of 62 VOCs, only 11 VOCs were not detected in runoff samples, while 14 VOCs were detected in 27 groundwater samples. The toluene content in the runoff was extremely variable from 0.1ppb to 29,310ppb, depending on the different sampling sites. The concentrations of xylene ranged between 0.07ppb and 2970ppb in the runoff. The concentrations ranged from 0.05ppb to 33.0ppb for benzene, 0.05ppb to 960ppb for ethylbenzene, 0.08ppb to 20ppb for trichloromethane (chloroform) , 0.03ppb to 4.30ppb for trichloroethylene(TCE) and 0.1ppb to 50ppb for 1,1,2-trichloroethane. From the preliminary study of groundwater from some wells in Seoul, the most frequently detected VOCs are djchlorornethane(methylene chloride), trichloromethane(chloroform) and toluene. Most of aromatic hydrocarbons, alkyl benzenes and other solvents generally lower than detection limits.

  • PDF

A Study for Reductive Degradation and Surface Characteristics of Hexachloroethane by Iron Sulfide ($FeS,\;FeS_{2}$) (황화철($FeS,\;FeS_{2}$)을 이용한 헥사클로로에탄의 환원적 분해반응과 표면특성에 관한 연구)

  • Park Sang-Won;Kim Sung-Kuk;Heo Jae-Eun
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.35-42
    • /
    • 2006
  • The following results were obtained in the reductive degradation of hexachloroethane (HCA), and surface characteristics by using iron sulfide ($FeS,\;FeS_{2}$) mediators. HCA was degraded to pentachloroethane (PCA), tetrachloroethylene(PCE), trichloroethylene(TCE) and cis-l,2-dichloroethylene (cis-1,2-DCE) by complicated pathways such as hydrogenolysis, dehaloelimination and dehydrohalogenation. FeS had more rapid degradation rates of organic solvent than $FeS_{2}$. In liquidsolid reaction, the reaction rates of organic solvents were investigated to explain surface characteristics of FeS and $FeS_{2}$.. To determine surface characteristics of FeS and $FeS_{2}$, the specific surface area and surface potential of each mineral was determined and the hydrophilic site ($N_{s}$) was calculated. The specific surface area ($107.0470m^{2}/g\;and\;92.6374m^{2}/g$) and the $pH_{ZPC}$ of minerals ($FeS\;PH_{ZPC}=7.42,\;FeS_{2},\;PH_{ZPC}=7.80$) were measured. The results showed that the Ns of FeS and $FeS_{2}$ were $0.053\;site/mm^{2}\;and\;0.205\;site/mm^{2}$, respectively. $FeS_{2}$ had more hydrophilic surface than FeS. In other words, FeS have more hydrophobic surface site than $FeS_{2}$.

Desorption Efficiency of Various Cosolvents for Organic Solvent Mixtures Collected on Activated Charcoal Tube (활성탄관에 포집된 혼합 유기용제의 보조탈착용매 변화에 따른 탈착률 비교)

  • Kim, Kang Yoon;Ro, In Bong;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.209-221
    • /
    • 1996
  • The purpose of this study was to find a suitable cosolvent to $CS_2$ so that desorption efficiency can be improved for both polar and non-polar organic solvent mixtures collected on an activated charcoal tube. Cosolvents added to $CS_2$ include: DMF(N,N-dimethylformamide): $CS_2$ (v/v 1:99), DMF:$CS_2$(v/v 3:97), BC (butyl carbitol, 2-(2-butoxy ethoxy) ethanol):$CS_2$(v/v 1:99), and BC:$CS_2$(v/v 3:97)). The results obtained were as follows : 1. Comparing the desorption efficiency of $CS_2$ with those of $CS_2$ with 1, 3, 5 % DMF and 1, 3 % BC cosolvents for two different groups of charcoal tubes each containing 8 different polar and non-polar organic solvents with 3 different concentration levels, the desorption efficiencies of the cosolvent-added $CS_2$ increased significantly for all polar organic solvents regardless of concentration levels tested. For non-polar organic solvents, no noticeable improvement was detected except xylene and trichloroethylene. The desorption efficiency of xylene increased significantly while that of trichloroethylene increased significantly at the lowest concentration level tested. 2. Either 5 % DMF or 3 % BC was the most suitable cosolvent because the desorption efficiency for non-polar organic solvent mixtures was similar or slightly improved compared with that of $CS_2$, while those of for polar organic solvent mixtures were above 75 % except for cyclohexanone. 3. The smallest variations in desorption efficiency represented by the ratio calculated from the maximum to minimum desorption efficiency for all concentration levels tested were found when 3 % BC was used as a cosolvent. The above results indicate that the desorption efficiency of $CS_2$ particularly for polar organic solvent mixtures collected on a charcoal tube can be significantly improved by the use of cosolvents such as 5 % DMF or 3 % BC. A caution, however, is in order for selecting a cosolvent whenever the cosolvent itself is being used in the workplace or the impurities contained in the cosolvent may interfere with the analytical results. In addition, to improve desorption efficiencies for such organic solvents as cyclohexanone or ketones, it is recommended to use suitable collection and desorption media other than the traditional method of charcoal tube collection/$CS_2$ desorption.

  • PDF

Exposure of Carcinogens in Electronics Industries and Strategy for Control of Carcinogens: Using Work Environment Measurement Database (2013-2017) in Korea (한국 전자산업에서 작업환경측정을 통해 파악된 발암물질들 노출 특성과 발암물질관리 방안: 작업환경측정자료(2013-2017)를 중심으로)

  • Mia, Son;Jaewon, Yun;Yu Seoung, Hwang;Mijin, Park;MinSeo, Choi;Mi-Young, Lee;Domyung, Paek
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.302-324
    • /
    • 2022
  • Objectives: The objective of this study is to investigate exposure to occupational carcinogens in the nationwide electronics industries and to establish a strategy for control of occupational carcinogens in South Korea. Methods: We evaluated occupational carcinogens as defined by International Agency for Research on Cancer (IARC) using a nationwide work environment measurement database on the electronics industry in South Korea measured between 2013 and 2017 in accordance with the Occupational Safety and Health Act. Results: The number of occupational carcinogens found in the electronics industry in South Korea were: 20 for IARC Group 1, 14 for Group 2A, and 30 for Group 2B. The occupational carcinogens (Group 1) most frequently exposed were strong-inorganic-acid mists containing sulfuric acid (sulfuric acid), welding fumes, mineral oils (untreated or mildly treated), nickel compounds, silica dust, crystalline substances in the form of quartz or cristobalite, formaldehyde, arsenic and inorganic arsenic compounds, chromium (VI) compounds, trichloroethylene, cadmium and cadmium compounds, vinyl chloride, ethylene oxide, wood dust, beryllium and beryllium compounds, 1,3 butadiene, benzene, and others. Among them, the carcinogens (Group 1) exceeding the acceptable standard were trichloroethylene, formaldehyde, and ethylene oxide. The working environment measurement system as regulated by Occupational Safety and Health Act is not properly assessed and managed for occupational carcinogens in South Korea. A component analysis for all materials used should be set up to practically reduce occupational carcinogens. A ban on the use of occupational carcinogens and the development of alternative materials are needed. The occupational carcinogens below the acceptable standards should be carefully examined and a new standard for exposure needs to be established. Conclusions: The Occupational Safety and Health Act should be improved to identify and monitor occupational carcinogens at work sites. A strategy for occupational safety and health systems should be provided to give direction to workers' needs and right to know.

Removal of Chlorinated Organic Compounds Using Crosslinked PDMS Pervaporation Membrane (가교된 PDMS 투과증발 막을 이용한 유기 염소계 화합물의 제거)

  • Kim, Yong Woon;Hong, Yeon Ki;Hong, Won Hi
    • Clean Technology
    • /
    • v.7 no.3
    • /
    • pp.195-202
    • /
    • 2001
  • In this study the trace of chlorinated organic compound in aqueous solution was separated by pervaporation process using crosslinked PDMS (polydimethylsiloxane) membrane. The flux of trichloroethylene(TCE) increased linearly with feed composition but the flux of water was slightly increased. The partial flux of TCE was greater than that of tetrachloroethylene(PCE). The partial flux of TCE was not changed with operating temperature, but increased rapidly with feed flow rates. High crosslinking density causes the reduction of solubility and diffusivity for target component. The reduction of flux and selectivity for TCE is due to the chain immobilization and reduction of diffusivity with crosslinking density.

  • PDF

Oxidative Decomposition of TCE over TiO2-Supported Metal Oxide Catalysts (TiO2에 담지된 금속 산화물 촉매상에서 TCE 산화분해반응)

  • Yang Won-Ho;Kim Moon-Hyeon
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.221-227
    • /
    • 2006
  • Oxidative TCE decomposition over $TiO_2$-supported single and complex metal oxide catalysts has been conducted using a continuous flow type fixed-bed reactor system. Different types of commercial $TiO_2$ were used for obtaining the supported catalysts via an incipient wetness technique. Among a variety of titanias and metal oxides used, a DT51D $TiO_2\;and\;CrO_x$ would be the respective promising support and active ingredient for the oxidative TCE decomposition. The $TiO_2-based\;CrO_x$ catalyst gave a significant dependence of the catalytic activity in TCE oxidation reaction on the metal loadings. The use of high $CrO_x$ contents for preparing $CrO_x/TiO_2$ catalysts might produce $Cr_2O_3$ crystallites on the surface of $TiO_2$, thereby decreasing catalytic performance in the oxidative decomposition at low reaction temperatures. Supported $CrO_x$-based bimetallic oxide systems offered a very useful approach to lower the $CrO_x$ amounts without any loss in their catalytic activity for the catalytic TCE oxidation and to minimize the formation of Cl-containing organic products in the course of the catalytic reaction.

APPLICATION OF A PILOT-SCALE FLUIDIZED-BED REACTOR FOR THE DECONTAMINATION OF GROUNDWATER

  • Ohlen, Ken;Lee, Seong-Taek;Hegemann, Wemer;Jang, Yong-Geun
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.77-80
    • /
    • 2001
  • Groundwater, contaminated predominantly with aromatic compounds and chlorinated ethylene, could be biologically treated in a fluidized-bed reactor with immobilized cells. The decomposition efficiency for the aromatics was over 90% at the retention time of 2.5 h. The chlorinated ethylenes, especially trichloroethylene (TCE) and cis-dichloroethylene (DCE), could be decomposed only insufficiently. No anaerobic methane formation was observed for this groundwater even at a very low dissolved oxygen (DO) concentration of 0.75 mg/L. The variation of DO concentration resulted in an optimal value of 1.5 mg/L. The recycle of air waste could increase the utilization of oxygen. The amount of low boiling pollutants stripped out remained constant with the recycle, while for the higher boiling pollutants the stripping slightly increased. Using air instead of oxygen increases the flow rate of air waste, which is connected to a higher stripping of pollutants. In this investigation, the pollutant concentration in the air waste remained constant. The stripping of main pollutants did not exceed 0.3 %.

  • PDF