Guideline for Imaging Dose on Image-Guided Radiation Therapy (영상유도방사선치료에 있어 영상선량 가이드라인)

  • Cho, Byung Chul;Huh, Hyun Do;Kim, Jin Sung;Choi, Jin Ho;Kim, Seong Hoon;Cho, Kwang Hwan;Cho, Sam Ju;Min, Chul Kee;Shin, Dong Oh;Lee, Sang Hoon;Park, Dong Wook;Kim, Kum Bae;Choi, Sang Hyoun;Kim, Hye Young;Ahn, Woo-Sang;Kim, Tae Hyeong;Han, Su Cheol
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.1-24
    • /
    • 2013
  • As image-guided radiation therapy (IGRT) has been commonly used for more accurate patient setup and monitoring tumor movement during radiation therapy, the necessity for management of imaging dose is increased. However, it has not been an interest issue to radiation therapy communities because the imaging dose is much lower than the therapeutic dose. However, since the cumulative dose from 4DCT and repeated imaging for daily setup verificationin would not be ignorable, appropriate dose management based on ALARA (As Low As Reasonably Achievable) principle is required. In this study, we aimed that (1) survey on imaging equipments and modalities used for IGRT, (2) estimation of IGRT imaging dose depending on treatment types and equipments, (3) collecting data of effective dose on treatment sites from each equipment and imaging protocol, and thus finally provide guideline for imaging dose reduction and optimization.

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

The Effected Factors on Customer Satisfaction of Medical Service and Willingness to Revisit among Selected Hospital Users in a Local City (일 지방 도시의 종합병원 이용자들의 의료서비스 만족도와 재이용 의사에 미치는 요인)

  • Seo, Seung-Hee;Park, Jong-Young;Han, Sung-Hyun
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.89-100
    • /
    • 2005
  • Objectives: This study was to find the effected factors on customer satisfaction for medical service and the willingness to revisit among hospital users Methods: The data was collected by a questionnaire survey from February 1 to April 30, 2004, and 600 samples have been analysed among users of university hospital, private hospital and public hospital in a local city. Results and Conclusions: The satisfaction total score to use hospital was 113.54 points(out of 175 point), these scores were constituted 39.10 points(out of 55 point) on satisfaction score for kindness of hospital employee, 36.28 points(out of 60 point) for equipment utilization and service formality, 18.59 points(out of 30 point) for environmental status and 19.57 points(out of 30 points) for reliability in medical examination and treatment service. The factors effected on satisfaction total score to use hospital were type of visiting hospital, age of customer, convenience to visit the hospital, experience of using other hospitals(R2=0.171). The effected factors of willingness to revisit scores were such as satisfaction score in medical examination and treatment service, satisfaction score of kindness hospital employee, experience of health examination and age of customer($R^2=0.370$). In conclusion, to raise the response's willingness to revisit. This must be reinforced by employee's kindness education and medical service quality.

  • PDF

A study on the manufacturing method and usefulness of Bolus-helmet used for malignant scalp tumor patients (악성두피종양환자에게 사용되는 보루스헬멧(Bolus-helmet)의 제작방법 및 유용성에 관한 연구)

  • Lee, joung jin;Moon, jae hee;Kim, hee sung;Kim, koon joo;Seo, jung min;Choi, jae hoon;Kim, sung gi;Jang, in gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.15-24
    • /
    • 2021
  • This study is about the introduction and usefulness evaluation of the manufacturing method of the bolus-helmet. Helmet-production for the treatment of scalp tumor patients has been tried and will continue in many creative and various ways. However, Most of the research data did not significantly reduce the psychological burden and physical and physical discomfort that the patient had to bear due to the time and economic cost required for the production of the helmet, the convenience of production, and the complexity of the process. In addition, recently, studies using more advanced technologies and equipment such as 3D-printer technology, which are being studied as a way to increase the treatment effect, are being introduced, but the time, economic cost, and psychological and physical burden are still the sole responsibility of the patient. Isn't it getting worse? The reality is that the thoughts of concern cannot be erased. Therefore, by maintaining the physical properties of the bolus and manufacturing a helmet without incurring additional costs, the physical and physical discomfort aggravated to the patient was reduced and the procedure and time for helmet manufacturing were minimized. In this way, it was possible to reduce the time, economic cost, and physical discomfort required for the production of the helmet, and it was also possible to minimize the psychological burden of the patient, although it is invisible. Additionally, in evaluating the usefulness of helmets, we are able to continuously seek and develop ways to reduce the air-gap interval, and as a result, we will be able to introduce a method to keep it within 2.0mm along with the manufacturing method through this study. I feel very welcome. Finally, I hope that anyone working in the Department of Radiation Oncology will be able to easily manufacture the helmet required for radiation therapy using a bolus through the guide-line on helmet manufacturing provided by this institute. I hope and hope that if you have any questions or inquiries that arise during the production process, please feel free to contact us through the researcher's e-mail or mobile phone at any time.

A Study on the Relationship among Skin Care Situations, Skin Care Recognition, and Skin Care Satisfaction by Gender in Medical Skin Care Center Patients: - Focused on Females and Males in Hainan Province, China-

  • Jia, Yue;Kim, Kyeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.173-181
    • /
    • 2021
  • Chinese people have increasingly high interests in skin care and trust and prefer medical institution products and equipment to treat skin problems. The purpose of this study is to examine skin types and skin care situations, skin care recognition, and skin care satisfaction by gender in medical skin care center patients from in their 10s to 50s in Hainan Province, China. The questionnaire survey consisted of general characteristics(n=8), skin care situations(n=6), skin care recognition(n=11), and skin care satisfaction(n=21). A total of 328 questionnaires were researched from December 21, 2020 to January 9, 2021 using WeChat and Wenjuanxing program. Data were analyzed by SPSSWIN 21.0. Frequency analysis was applied for general characteristics, skin care situations, skin care recognition, and skin care satisfaction and Cronbach's α was used for the reliability of skin care recognition and satisfaction. The relationship among skin care situations, skin care recognition, and skin care satisfaction was analyzed by χ2 test and t-test. As a result, the common skin types by gender was dry skin in females and oily skin in males. The highest skin trouble was melasma and pigments in females and pimple in males. The most common way to manage troubled skin was homecare in both females and males, followed by the dermatology department in females and pharmacy in males, suggesting a significant difference. The common period of skin trouble was from one year to three years and the most effective way to improve skin was good life habit, followed by laser treatment in both females and males. The most important consideration to choose a hospital was a famous franchise hospital and the most important matters in management was doctor or skin care professionalism. Skin care and treatment recognition was high in external effects for females and internal effects for males. Skin care satisfaction was high in service for females and effect for males. Skin care satisfaction was significantly higher in males than in females. In conclusion, there was a difference in skin types, skin troubles, skin problems, skin care ways, and skin care satisfaction by gender in Chinese medical skin care center patients. Therefore, this study suggests the development of various products and the need of systematic management programs.

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Facters Affecting Recurrence after Video-assisted Thoracic Surgery for the Treatment of Spontaneous Pneumothotax (자연기흉에 대한 비디오흉강경수술후 재발에 영향을 미치는 요인들)

  • 이송암;김광택;이일현;백만종;최영호;이인성;김형묵;김학제
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.448-455
    • /
    • 1999
  • Background: Recent developments in techniques of video-assisted thoracic surgery(VATS) and endoscopic equipment has expanded the application of video-assisted surgical procedures in the field of thoracic surgery. Especially, it will probably become the treatment of choice of spontaneous pneumothorax(SP). There is, however, a high recurrence rate, high cost, and paucity of long-term results. We report the results of postoperative follow-up and analyze perioperative parameters affected to recurrence, retrospectively. Material and Method: From march 1992 to march 1997, 276 patients with spontaneous pneumothorax underwent 292 VATS procedures. Conversion to open thoracotomy was necessitated in eight patients, and this patients excluded from the study. Result: The sex distribution was 249 males and 31 females. The mean age was 28.1 12.2 years(range, 15 to 69 years). Primary SP was 237cases(83.5%) and secondary SP was 47cases(16.5%). The major underlying lung diseases associated with secondary SP were tuberculosis 27cases(57.4%) and emphysema 8cases (38.3%). Operative indications included Ipsilateral recurrence 123(43.9%), persistent air-leak 53(18.9%), x-ray visible bleb 40(14.3%), tension 30(10.7%), contralateral recurrence 21(7.5%), uncomplicated first episode 8(2.9%), bilateral 3(1.1%), complicated episode 2(0.7%). Blebs were visualized in 247cases(87%) and 244cases(85.9%) performed stapled blebectomy. Early postoperative complications occurred in 33 cases(11.6%): 16 prolonged air-leak more than 5 days(four of them were required a second operation and found missed blebs); 5 bleeding; 5 empyema; 2 atelectasis; 1 wound infection. No deaths occured. The mean operative time was 52.8 23.1 minutes(range, 20 to 165 minutes). The mean d ration of chest tube drainage was 5.0 4.5 days(range, 2 to 37 days). The mean duration ofhospital stay was 8.2 5.5 days (range, 3 to 43days). At a mean follow-up 22.3 18.4 months(range, 1 to 65 months), 12 patients(4.2%) were lost to follow-up. There were 24 recurrences and seven patients underwent second operation and 6 patients(85.7%) were found the missed blebs. 12 perioperative parameters(age, sex, site, underlying disease, extent of collapse, operative indication, size of bleb, number of bleb, location of bleb, bleb management, pleural procedure, prolonged postoperative air-leak) were analyzed statistically to identify significant predictors of recurrence. The significant predictors of recurrence was the underlying disease[17.0%(8/47): 6.8%(16/237), p=0.038], prolonged postoperative air-leakage[37.5%(6/16): 6.7%(18/268), p=0.001], and pleural procedure [11.4%(19/167): 4.3%(5/117), p=0.034]. Blebectomy has less recurrence rate then non-blebectomy [8.2%(20/244) : 10.0%(4/40), p>0. 5]. However, this difference was not statistically significant(p=0.758). Conclusion: We conclude that it is important that we shoud careful finding of bleb during VATS due to reducing of recurrnece, and cases of no bleb identified and secondary spontaneous pneumothorax were indicated of pleurodectomy. VATS is a valid alternative to open procedure for the treatment of spontaneous pneumothorax with less pain, shorter hospital stay, more rapid return to work, high patient acceptance, less scar and exellent cosmetics. But, there is high recurrence rate and high cost, and than it is necessary to evaluate of long-term results for recurrence and to observate carefully during VATS.

  • PDF

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

A Survey on the Perception of the Counterplans of Medical Accident and Dispute of Dental Hygienist (의료사고 및 의료분쟁에 대한 치위생사의 인식도 조사)

  • Oh, Jin-Ho;Kwon, Jeong-Seung;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.1
    • /
    • pp.9-33
    • /
    • 2007
  • In the field of dentistry, there existed relatively few emergency patients or patients who need intensive care and thus had low medical dispute rates. However, these days, there is a general tendency of increased medical disputes. Although many medical disputes are caused by medical accidents of the dentists, because dental assistants are also lawfully involved in practicing dentistry, there is a possibility of medical disputes or medical accidents caused by dental assistants. Therefore, the role of the dental assistants cannot be ignored. This study consists of a survey given to dental hygienists currently working in general hospitals, dental hospitals and private dental clinics. Following is the results of the analysis of 275 respondents' backgrounds, medical disputes rates including patients' complaints, their understanding of medical regulations and their general understanding of overall dental practice and medical disputes. 1. 251 of 274(91.6%) respondents doubted the risk of medical accident and dispute. 2. 81(29.5%) dental hygienist experienced complaint from patients. They have been working in the private dental clinic, the rate of this experience was high. 3. 349 case of 1805(19.3%) the complaints by patients, highest percentage among its category, were those regarding dental fees and poor service. 4. 129 case of 1805(7.1%) patients' complaints, highest percentage among it's subcategory, were those regarding the absence of explanations of precautions or request of agreements before dental treatment. 5. 252 of 267 (94.4%) dental hygienists chart after a scaling treatment. However, only 55(20.7%) dental hygienists chart the fact of explaining the precautions. 6. 6(2.2%) dental hygienists do not inspect patients' medical history, if patients don't mention it. 7. 104 of 274(38.0%) dental hygienists responded to be capable of administering first aid treatment. 8. 115(41.8%) dental hygienists have a first aid kit and equipment. 9. In case of medical dispute, 268(97.8%) dental hygienists respond that, charting plays a big role in resolving the dispute. 10. In case of medical dispute, 272(93.3%) dental hygienists respond that, explanation and agreement before treatment have an important role in settlement of dispute 11. Only 160(58.4%) dental hygienists responded correct answer that the duration of keeping medical records is 10 years. 12. 124(45.3%) respondents thought that it is legal for a dental hygienist to take a panoramic dental X-ray, 71(25.9%) respondents thought that it is legal practice cervical resin treatment by dental hygienist, and 37(13.5%) respondents thought that it is legal extract primary teeth by dental hygienist. 13. 24(18.76%) respondents thought that it doesn't matter to tell patient's state to others 14. 272(99.27%) responded that receiving education for the prevention of medical disputes was needed and of them, 61.0% thought it was urgent. 15. 186(64.2%) has never had classes regarding the prevention of medical disputes while in school and 212(77.4%) has not had the same type of classes after graduating from school. 16. 256(93.4%) responded that there will be even more of an increased number of medical disputes. Among them, 83.3% of respondents though that due to the increased opportunity of acquiring information through the internet and mass media. The study shows that 29.5 percentage of dental hygienists have experienced the medical disputes and complaints and they are lack of recognition of medical regulations and dental hygienist's official duty. So, there is a big potential of the percentage to increase. Therefore, the correct understanding of explaining precautions and requesting agreement before dental treatments and performing them are mandatory. Moreover, classes regarding the prevention and counterplans of medical disputes need to be widely offered.