Sensor State Isolation for Wastewater Based on Influent Characteristics Methodology (물질수지분석을 이용한 하수처리장 유입수질 측정 센서의 상태 진단)

  • Baek Jiwon;Kim Jongrack;You Kwangtae;Kim Yejin
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.4
    • /
    • pp.168-178
    • /
    • 2024
  • Wastewater treatment plants are constantly exposed to influent wastewater that is constantly changing. This poses a major challenge to the operation of the plants. It is crucial to have a rapid and accurate measurement of the influent concentrations of wastewater in order to maintain and optimize treatment performance, as well as to develop energy-saving strategies. While laboratory measurements provide the highest accuracy in determining influent water quality, they are inevitably time-consuming procedures. In order to cope with the ongoing disturbances from wastewater influent, absorption-based optical measuring instruments have been developed. These instruments can detect the influent water quality in a short amount of time, improving their practicality and reliability. However, when these optical measuring instruments malfunction, the accuracy of the measured values decreases, leading to unreasonable operation of the treatment plant. This paper proposes a method for detecting anomalies in optical water quality measurement devices. The Harmony Search algorithm is used to validate the measured water quality values and detect abnormalities such as contamination or physical anomalies in the measurement apparatus. To assess the performance of the developed algorithm in detecting anomalies, validation was conducted by installing it in a field-scale wastewater treatment plant. The results consistently showed that the developed fault detection method for optical water quality measurements equipment provided acceptable results for normal, temporary abnormal, and long-term abnormal conditions.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

A Study on the Correlation between Pulse Energy and Sasang Constitutional Syndromes (맥 Energy와 사상체질병증의 연계 연구)

  • Kim, Dal-Rae;Kim, Sun-Hyung
    • The Journal of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.26-39
    • /
    • 2009
  • Objectives: Pulse energy values recorded with an add-pres sure-type pulse apparatus were correlated with Sasang constitutional syndromes in order to match pulse energy values with Sasang prescriptions. Methods: The pulse energy values were measured with Daeyo Pulse Apparatus at the Gwan pulse point of both wrists. Prescriptions were divided into two major categories of interior syndromes or exterior syndromes, and categorized according to major component herbs specific to each of the four Sasang constitutions, and the relationship between the pulse energy and each groups divided by their prescription was studied. Results: About 10% of all people had nonmal pulse energy values. 10% had values over normal range, and $70\sim80%$ had lower values than normal. The normal range of pulse energy was regarded as being between 450 and 700. Conclusions: 1. For patients of the Soeum constitution, prescriptions without Panax ginseng is suitable for patients with high pulse energy, and prescriptions containing Panax ginseng are suitable for patients who have lower pulse energy. 2. All prescriptions for the Soyang constitution containing Rehmannia radix preparata or Comus officinalis are suitable for patients who have lower pulse energy, and prescriptions containing Rehmannia radix or Gypsum fibrosum are applicable to patients with pulse energy values higher than normal. 3. Most prescriptions for the Taeum constitution containing Semen coicis or Semen castaneae are suitable for patients with lower pulse energy, and prescriptions containing Radix puerariae or Radix et rhizoma rhei can be prescribed for patients who have lower pulse energy levels. 4. The Taeyang constitutional prescription Ogapijangcuck-tang is suitable for patients who have higher pulse energy levels and Mihudeungsikjang-tang is better for patients with lower than normal pulse values. As described above, the pulse energy level of each patient can be matched with a specific Sasang constitutional prescription. If this relationship is taken into consideration with other conventional symptoms, it can be helpful in diagnosis, improving efficacy of treatment, and be used as objective evidence.

  • PDF

A Study of Cadmium Recovery from LCC Crucible Using Solid-liquid Separation Method (고-액 분리법을 이용한 LCC 도가니에서의 카드뮴 회수에 관한 연구)

  • Park, Dae-Yeob;Kim, Tack-Jin;Kim, Jiyong;Kim, Kyung-Ryang;Kim, Si-Hyung;Shim, Joon-Bo;Peak, Seungwoo;Ahn, Do-Hee
    • Journal of Advanced Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.431-436
    • /
    • 2011
  • This study was carried out to reduce the problem during distillation process, which separate U, TRU (TRans Uranium) metal electro deposit, Cd and LiCl-KCl eutectic salt generating from LCC (Liquid Cadmium Cathode) electro winning process. The cadmium recovering apparatus was manufactured to separate for each metal using solid-liquid separation method. The apparatus consists of the first sieve for the separation of U and TRU metal electrodeposit, the second sieve for the separation of LiCl-KCl eutectic salt, cadmium collection basket, and a heating furnace. In addition, the size of each sieve is 2 mm to 3 mm. In this experiment, a metal wire was employed to replace TRU metal electrodeposit and U, which exist actually in a LCC crucible. In the solid state, The LiCl-KCl is separated at 340℃ at which the solid and the liquid of the remaining cadmium and LiCl-KCl eutectic salt coexists in each, after the metal wire separated at 500℃. As a result, it seems that it would be beneficial to set the processing condition in the distillation process with the additional treatment process of cadmium and LiCl-KCl eutectic salt.

Photoinhibition Induced Alterations in Energy Transfer Process in Phycobilisomes of PS II in the Cyanobacterium, Spirulina platensis

  • Kumar, Duvvuri Prasanna;Murthy, Sistla D.S.
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.644-648
    • /
    • 2007
  • Exposure of algae or plants to irradiance from above the light saturation point of photosynthesis is known as high light stress. This high light stress induces various responses including photoinhibition of the photosynthetic apparatus. The degree of photoinhibition could be clearly determined by measuring the parameters such as absorption and fluorescence of chromoproteins. In cyanobacteria and red algae, most of the photosystem (PS) II associated light harvesting is performed by a membrane attached complex called the phycobilisome (PBS). The effects of high intensity light (1000-4000 ${\mu}mol$ photons $m^{-2}s^{-1}$) on excitation energy transfer from PBSs to PS II in a cyanobacterium Spirulina platensis were studied by measuring room temperature PC fluorescence emission spectra. High light (3000 ${\mu}mol$ photons $m^{-2}s^{-1}$) stress had a significant effect on PC fluorescence emission spectra. On the other hand, light stress induced an increase in the ratio of PC fluorescence intensity of PBS indicating that light stress inhibits excitation energy transfer from PBS to PS II. The high light treatment to 3000 ${\mu}mol$ photons $m^{-2}s^{-1}$ caused disappearance of 31.5 kDa linker polypeptide which is known to link PC discs together. In addition we observed the similar decrease in the other polypeptide contents. Our data concludes that the Spirulina cells upon light treatment causes alterations in the phycobiliproteins (PBPs) and affects the energy transfer process within the PBSs.

Color Enhancement of the Type II and Type I aB Brown Diamonds into Colorless by HPHT Process (고온고압법에 의한 Type II, Type I aB 갈색 다이아몬드의 색향상)

  • Song, Jeong-Ho;Song, Oh-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.3
    • /
    • pp.221-225
    • /
    • 2012
  • It is possible to enhance the color of the natural diamond with a high pressure high temperature(HPHT) process. We employed a pyrophyllite tube cell and cubic press apparatus for HPHT treatment on the brown colored Type II (5.6 GPa/ $1700^{\circ}C$/ 52 min), and Type I aB(5.6 GPa/ $1650^{\circ}C$/ 30 min) diamond samples. We investigated the microstructure, Types, fluorescence, properties of the diamonds with an optical microscopy, FT-IR, photoluminescence(PL) spectroscopy, Diamond-View, and micro-Raman spectroscopy. Two tinted brown diamonds changed into colorless just after the HPHT process. Optical microscopy showed that no crack and significant inclusion evolution occurred during the HPHT process except the small graphite spot appeared in Type I aB sample. FTIR spectrum confirmed that no Type, amber center, and platelet defect change with the HPHT treatment. Diamond-View could not distinguish the HPHT treated diamonds from the naturals. PL spectroscopy showed that N3 and H3 color centers remained even after HPHT process. Consequently, we successfully changed the color of diamonds into colorless by 5.6 GPa HPHT process.

Effect of Tauroursodeoxycholic Acid on Ischemia/Reperfusion Injury in Isolated Rat Heart (타우로우루소데옥시콜린산이 흰쥐의 적출심장에서 허혈 및 재관류 손상에 미치는 영향)

  • 한석희;이우용;박진혁;이선미
    • Biomolecules & Therapeutics
    • /
    • v.7 no.4
    • /
    • pp.354-361
    • /
    • 1999
  • In this study, the effects of tauroursodeoxycholic acid (TUDCA) on ischemia/ reperfusion injury were investigated on isolated heart perfusion models. Hezrts were perfused with oxygenated Krebs-henseleit solution (pH 7.4, $37^{\cire}C$) on a Langendorff apparatus. After equilibration, isolated hearts were treated with TUDCA 100 and 200 $\mu\textrm{M}$ or vehicle (0.02% DMSO) for 10 min before the onset of ischemia in single treatment group. In 7 day pretreatment group. TUDCA 50, 100 and 200 mg/kg body weight were given orally for 7 days before operation. After global ischemia (30 min), ischemic hearts were reperfused for 30 min. The physiological (i.e. heart rate, left ventricdular developed pressure, coronary flow, double product, time to contracture formation) and biochemical (lactate dehydrogenase; LDH) parameters were evaluated. In vehicle-treated group, time to contracture formation was 810 sec during ischemia, LVDP was 34.0 mmHg at the endpoint of reperfusion and LDH activity in total reperfusion effluent was 34.3 U/L. Single treatment with TUDCA did not change the postischemic recovery of cardiac function, LDH and time to contractur compared with ischemic control group. TUDCA pretreatment showed the tendency to decrease LDH release and to increase time to contracture and coronary flow. Our findings suggest that TUDCA does not ameliorate ischemia/reperfusion-reduced myocardial damage.

  • PDF

Manufacturing and Characteristics Analysis of PU/MWNT Composite Film for Forming (발포용 PU/MWNT 복합필름의 제조와 특성분석)

  • Park, Jun-Hyeong;Kim, Jeong-Hyun;Kim, Seung-Jin
    • Textile Coloration and Finishing
    • /
    • v.22 no.4
    • /
    • pp.362-372
    • /
    • 2010
  • This paper surveys the physical properties of the multiwall carbon nanotube (MWNT) and polyurethane composite film for improvement of mechanical properties and electrical characteristics. The modification of MWNT was carried out by acid treatment with nitric and sulphuric acid mixed solution, and then followed by thermal treatment for enhancing MWNT dispersion with polyurethane. This modified MWNT was mixed with polyurethane by changing the loading content of MWNT and dispersion time under the dimethylformamide solution in the ultrasonic wave apparatus. Various physical characteristics of the modified PU/MWNT films were measured and analyzed in terms of the loading content and dispersion time. The maximum absorbance of the PU/MWNT films were observed with the 2wt% loading at dispersion times of 2 and 24 hour, respectively. The minimum electrical volume resistivity of PU/MWNT film was shown at the loading content of 0.5wt% or more irrespective of dispersion treating time. However the optimum condition was assumed to 2wt% loading at dispersion time of 2 hours by assessing the surface profile of the film using video microscope. The breaking stress and strain of the PU/MWNT film decreased with increasing loading content, but no change of physical properties was shown with increasing in dispersion time.

Experimental Studies of quantitative evaluation using HPLC and safety of Bee Venom Acupuncture (봉독침의 봉독함량분석과 LD50 및 조직학적 소견 관찰)

  • Jang, Seong-Bong;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.9 no.1
    • /
    • pp.155-165
    • /
    • 2006
  • Objectives : This study was conducted to carry out quantitative evaluation and safety of Bee Venom Acupuncture. Methods : Content analysis was done using HPLC, measurement of $LD_{50}$, and histological observations were made on the skin and muscles. Results : 1. According to HPLC analysis, each BVA-1 contained approximately $0.36{\mu}g$, and BVA-2 contained approximately $0.54{\mu}g$. But the volume of coating was so minute, slight difference exists between each needle. 2. LD50 of mouse with BVA-1 was 16 counts and this is equivalent to 640 needles/kg, making Bee Venom Acupuncture safe treatment apparatus. 3. Regardless of the number of needles, there was no sign of blood stasis or inflammation detected on the skin and muscle tissues. Conclusion : Above results indicate that the Bee Venom Acupuncture can complement shortcomings of syringe usage as a part of Oriental medicine treatment, but extensive researches should be done for further verification.

Change of Lumbar Multifidus Muslce Recorded Simultaneously by Ultrasound Imaging during Upper Extremity Lifting Movement in Chronic Low Back Pain Patients (만성 요통 환자의 상지 기능적 동작시 초음파에 나타나는 다열근의 변화)

  • Jang, Won-Seok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose : The purpose of this study is change of lumbar multifidus muslce recorded simultaneously by ultrasound imaging during upper extremity functional movement in chronic low back pain patients. The subject were consisted of 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women. Methods : 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women is voluntary participated for the research. Subjects were positioned in standing. Multifidus size were measured from L4 vertebral segement. The ultrasound imaging apparatus(Sonoace 6000, Medison, Korea) was epuipped with a 5-MHz convex array transducer. The upper extremity lifting movement used to activate the multifidus was then measured. Results : Results of the analysis showed that at the L4 vertebral leves, healthy asymptomatic subjects had significantly larger multifidus muscle compared with chronic LBP subjects. Conclusion : This study will be used as treatment method of patient with chronic LBP. The multifidus muscle in chronic LBP patients clinical significance. Most of chronic LBP patients have multifidus contraction pattern. Especially multifidus contraction in L4 vertebral segement. So chronic LBP patients necessary multifidus muscle release treatment.

  • PDF