• Title/Summary/Keyword: Treatment Equipment

Search Result 943, Processing Time 0.027 seconds

Removal Ratio of Nitrogen & Phosphorus according to Sewage Inflow in the Biological Treatment(Biological Nutrient Removal)Process (유입하수에 따른 BNR에서의 N과 P 제거율에 관한 연구)

  • Lee, Han-Seob;Choi, Sung-Bu;Chung, Kwang-Bo;Ahn, Sung-Hwan;Kim, Kyung-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.669-678
    • /
    • 2014
  • The amount of waste water generated from the domestic sources is consistently increasing in proportion to economic growth, and the conventional activated sludge process is widely being used for general waste water treatment. But the ministry of environment becomes stringthent treatment standards of N and P (less than 20mg/L of N, 2mg/L of P) to prevent the eutrophication of lake water, and therefore highly advanced treatment technology is required not only in the existing treatment plants where the activated sludge process is being used, but also in newly constructed treatment plants for the treatment of N and P. This study is aimed at highly operating the engineering technology method was developed by domestic to eliminate N and P at the same time. Experiments were conducted in the treatment plant located in Yong In city. The bioreactor was started from the principal equipment for the elimination of N and P and the elimination of organic compounds. It consists of an internal recycle piping from the end of the aerobic tank to the anoxic tank and external recycle piping from the final settling basin to the denitrification tank. By experiment of 4 types separate inflow of waste water to the denitrification tank and the anaerobic tank, and changes in staying time at the anoxic tank and the aerobic tank, the elimination of organic compounds in each type and the relationship in the efficiency between the elimination of N and P were researched.

A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot (슬러리 양돈분뇨의 최적 고액분리 방안 연구)

  • Park, Seung-Kyun;Choi, Jae-Gil;Chung, Yoon-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.60-70
    • /
    • 2000
  • The swine wastewater from slurry feedlot has been a social problem in Korea since the proper treatment is very difficult. Therefore, a practical study on the Solid-Liquid separation of swine wastewater from slurry feedlot was carried out as a pan of pretreatment for the successful biological treatment. The appropriate type of coagulant and optimum dosage were proposed for the most efficient Solid-Liquid separation and the best Solid-Liquid separation methods for different size of feedlot were determined through the tests with field-scaled Solid-Liquid separation equipment. The appropriate coagulant for the conditioning of dewatering property was E-851, which is a cationic polyelectrolyte made of polyacrylamide, and the optimum dosage was 0.24~0.6% of unit solids weight. Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, High-speed Screw Decanter, Low-speed Screw Decanter, and Dissolved Air Flotation Process had been investigated in this study. According to the results, the Screw Press was the best dewatering equipment for the small & medium size for feedlot and low-speed Screw Decanter was the best for the large size feedlot & public owned treatment facilities for the primary Solid-Liquid separation, and the most suitable secondary treatment process was DAF. On the other hand, reductions for the requirement of bulking agent and organic loading by Solid-Liquid separation process were 94.8% and 84.7%, respectively Therefore, the Solid-Liquid separation process must be required for the successful treatment of swine wastewater from slurry feedlot.

  • PDF

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

Consideration on the Concentration of the Active Substances Produced by the Ballast Water Treatment System (선박평형수 처리장치의 활성물질 농도에 관한 고찰)

  • Kim, Eun-Chan;Oh, Jeong-Hwan;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • The International Maritime Organization (IMO) adopted the International Convention for the Control and Management of Ships' Ballast Water and Sediments in 2004 to prevent the transfer of aquatic organisms via ballast water. Thirty-four ballast water treatment systems were granted IMO active substance basic approval, among which twenty systems were granted final approval. This paper is an in-depth consideration of the mechanism principles of the treatment systems that received active substance basic or final approval from IMO, and on the concentration of Total Residual Oxidant (TRO). The TRO maximum allowable discharge concentration was reduced by neutralization equipment, resulting with a concentration lower than 0.2 ppm. However, between various treatment systems TRO maximum allowable dosage showed large differences, ranging from 1 to 15 ppm. The discrepancies of treatment allowable dosage concentration between different treatment systems are largely due to the properties of species and water conditions such as the temperature and turbidity, rather than the characteristics of treatment systems and the type or presence of filters etc.

Effect of speech therapy of patient with Velopharyngeal incompetence using CPAP (CPAP를 활용한 비인강폐쇄부전 환자의 언어치료 효과)

  • Oh Yoo-Kyung;Lee Yong-keun;Park Rae-Yon;Kim In-Soo;Shin Hyo-Keun;Kim Hyun-Gi
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.8 no.1
    • /
    • pp.39-44
    • /
    • 2005
  • Velopharyngeal incompetence(VPI) is that soft palate and muscle of posterolateral pharyngeal wall can not close velopharyngeal port properly. Thing that prior to treatment for patient with VPI is to evaluation about nasopharyngeal closing function. This data is important for making a treatment plan and assesment of treatment effect to improve nasopharyngeal closing function. There are two ways of VPI assessment. The one is subjective method by auditory finding, the other is objective method by using equipment for language test. Using only subjective way is not adequate for evaluation of VPI because of low trust, so doing both two methods simultaneously help to make a diagnosis and assessment exactly. CPAP is effective method to treat hypernasality. This new treatment technique intensify oropharyngeal muscle for nasopharyngeal closing by direct resistance training. Becase conventional treatments have limitation, so many research about treatment effectiveness of CPAP are being studied. This study aims that we compare our result from Korean VPI patients with result about treatment effect in other advanced country, to make CPAP Treatment Questionares and to find ways that improve oropharyngeal closing function an[1 maximally increase language treatment effect.

  • PDF

Reducing lesion incidence in pork carcasses by heating foot-and-mouth disease vaccine before injection

  • Cho, Jaesung;Ko, Eun Young;Jo, Kyung;Lee, Seonmin;Jang, Sungbong;Song, Minho;Jung, Samooel
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.4
    • /
    • pp.634-639
    • /
    • 2020
  • Objective: This study was conducted to investigate the effect of heating of foot-and-mouth disease (FMD) vaccine before injection, on the incidence of lesions at the injection site (pork butt), amount of discarded meat, and economical benefit. Methods: In total, 101,086 piglets raised in 30 farms, were vaccinated in the neck with 2 mL of FMD vaccine at 56 d and 84 d of age using a commercial syringe. The heat treatment group (48,511 pigs) was injected with the FMD vaccine after it had been heated in a water bath at 40℃ for 20 min. After slaughter, the incidence of lesions on the pork butt was inspected, and the subsequent amount of discarded meat was recorded. Results: Heat treatment of FMD vaccine reduced the incident rate of lesions on the pork butt (p<0.01). Overall, 17.81% of the pigs in the heat treatment group had lesions, while the incident rate in the control group was 21.70%. The amount of discarded meat per head of total pigs and per head of pigs with lesions were significantly lower in the heat treatment group than the control group (p<0.01). Thus, the proportion of discarded meat to dressed carcass was lower in the heat treatment group (0.249%) compared with the control group (0.338%) (p<0.01). Farms that rear 1,000 sows can gain 1,863,289 KRW (1,600 USD) in one year when they adopt heat treatment of FMD vaccine before injection. Conclusion: Heat treatment of FMD vaccine using simple heat equipment (water bath) can be effective in reducing lesions caused by FMD vaccination and increase the economic benefits in pig farms.

Electrodeposition behaviors of zinc from neutral chloride baths at high current density (중성염화물욕에서 아연의 고전류밀도 전착특성)

  • 김영근
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.4
    • /
    • pp.219-228
    • /
    • 1996
  • Neutral Zinc Electroplating(NZE) utilizing the electrolyte of pH 6 to 8 has advantages in waste treatment and the protection of equipment. NZE is beneficially used in chromating treatment, but the limiting current density and the current efficiency are low. Therefore this study is investigated to analyse the characteristics of NZE and to obtain high current density and current efficiency. The deposition potential of zinc in the NZE bath is about 110mV, which is lower than acidic bath. The current density possibily increases up to 60A/d$\m^2$ in lower complexing agent content and pH 6. More than 90% of cathodic current efficiency was obtained in NZE bath. The NZE morphology shows smaller grains than acidic bath. The addition of 4$m\ell$/1 second brightener gives finer morphology. As pH becomes higher, (002) plan decreases and (100), (101) and (110) planes increase in the no additives solution.

  • PDF

A Study on Wear Characteristics of Degraded Stainless Steel (열화된 스테인리스강의 마모특성에 관한 연구)

  • Cho, Sung-Duck;Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.21-30
    • /
    • 2017
  • This study deals with the characteristics of degraded stainless steel. Stainless steel is heat treated to ensure mechanical properties when designing or manufacturing machinery parts or equipment. In this study, the mechanical properties and wear characteristics of three kinds of stainless steels after artificially heat-treated at 753 K~993 K, where chrome depletion occurs near the grain boundary, were evaluated. The microstructure and fracture surface were also observed. From the results, friction coefficient and wear loss decreased with increasing the heat treatment temperature regardless of the type of stainless steel. Also, as the tensile strength increased, the friction coefficient and wear loss decreased. Wear loss showed proportional to a tendency to increase with increasing friction coefficient.

A study on mold design for microscopic bubble-producing air diffusers and on mold manufacture (미세기포 발생 산기장치 금형의 설계와 제작에 관한 연구)

  • Lee, Eun-jong;Choi, Kye-kwang;Kim, Sei-hwan
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2013
  • Sewage treatment plants are energy hogs. Among many, aeration systems account for 40-50 percent of the total energy use. To save energy, strengthening oxygen transfer characteristics is necessary. In order to do so, microscopic bubble-creating equipment is a prerequisite. This study focuses on microscopic bubble-producing air diffuser manufacture to save energy and enhance oxygen transfer.

  • PDF

Spontaneous Lead Breakage in Implanted Spinal Cord Stimulation Systems

  • Kim, Tae-Hun;Lee, Pyung-Bok;Son, Hye-Min;Choi, Jong-Bum;Moon, Jee-Youn
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.78-81
    • /
    • 2010
  • Spinal cord stimulation (SCS) has become an established clinical option for treatment of refractory chronic pain. Current hardware and implantation techniques for SCS are already highly developed and continuously improving; however, equipment failures over the course of long-term treatment are still encountered in a relatively high proportion of the cases treated with it. Percutaneous SCS leads seem to be particularly prone to dislocation and insulation failures. We describe our experience of lead breakage in the inserted spinal cord stimulator to a complex regional pain syndrome patient who obtained satisfactory pain relief after the revision of SCS.