• 제목/요약/키워드: Trapezoidal rule

검색결과 78건 처리시간 0.023초

Bioequivalence of Boryung Torsemide Tablet to Torem Tablet (Torasemide 10 mg) by High Performance Liquid Chromatography/UV Detector

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Chan-Ho;Kim, Se-Mi;Kim, Dong-Ho;Park, Sun-Ae;Kim, Kyung-Ran;Hur, Hyeon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권5호
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two torasemide tablets, Torem tablet (Roche Korea Co., Ltd., Korea, reference drug) and Boryung Torsemide tablet (Boryung Pharmaceutical Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (furosemide) to human serum, serum samples were extracted using 5 mL of ethyl acetate. Compounds were analyzed by reverse-phase HPLC method with UV detection. This method showed linear response over the concentration range of 0.05 ug/mL with correlation coefficient of 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ug/mL which was sensitive enough for pharmacokinetic studies. Twenty-eight healthy male Korean volunteers received each medicine at the torasemide dose of 20 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of torasemide were monitored by an HPLC-UV for over a period of 12 hr after the administration. $AUC_{t}$(the area under the serum concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum serum drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{t}$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_{t}$ ratio and the $C_{max}$ ratio for Boryung Torsemide/Torem were log 0.97-10g 1.03 and log 0.93log 1.12, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Boryung Torsemide tablet and Torem tablet are bioequivalent.

코자 정(로자탄 칼륨 50 mg)에 대한 로자르탄 정의 생물학적동등성 (Bioequivalence of LosartanTM Tablet to CozzarTM Tablet (Losartan Kalium 50 mg))

  • 김용원;박완수;김성수;서지형;조성희;이헌우;류재환;이경태
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권2호
    • /
    • pp.131-136
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two losartan tablets, $Cozaar^{TM}$ tablet (MSD Korea. Co., Ltd., Seoul, Korea, reference drug) and $Losartan^{TM}$ tablet (DaeWon Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the losartan kalium dose of 100 mg in a $2\;{\time}\;2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of losartan were monitored by an LC-MS/MS for over a period of 12 hr after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Cozaar^{TM}/Losartan^{TM}$ were $log\;0.97{\sim}log\;1.12\;and\;log\;0.93{\sim}log\;1.23$, respectively. These values were within the acceptable bioequivalence intervals of $log\;0.80{\sim}log\;1.25$. Taken together, our study demonstrated the bioequivalence of $Cozaar^{TM}$ and $Losartan^TM$ with respect to the rate and extent of absorption.

로아큐탄 연질캡슐(이소트레티노인 10 mg)에 대한 니메겐 연질캡슐의 생물학적동등성 (Bioequivalence of NimegenTM Soft Capsule to RoAccutane® Soft Capsule (Isotretinoin 10 mg))

  • 양승권;나숙희;장규영;이윤영;윤미경;유수현;이경률;이희주
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권4호
    • /
    • pp.255-261
    • /
    • 2007
  • A bioequivalence study of $Nimegen^{TM}$ soft capsule (Medica Korea Pharma. Co., Ltd.) to $RoAccutane^{(R)}$ soft capsule (Roche Korea Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Thirty healthy male Korean volunteers received each medicine at the isotretinoin dose of 60 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of isotretinoin were monitored by a high performance liquid chromatography (HPLC) for over a period of 48 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48 hr) was calculated by the linear trapezoidal rule method. $C_{MAX}$ (maximum plasma drug concentration) and $T_{MAX}$ (time to reach $C_{MAX}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{MAX}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{MAX}$ ratio for $Nimegen^{TM}/RoAccutane^{(R)}$ were $log0.860{\sim}log0.98\;and\;log0.85{\sim}log1.00$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Nimegen^{TM}\;and\;RoAccutane^{(R)}$ with respect to the rate and extent of absorption.

Enhanced Variable Structure Control With Fuzzy Logic System

  • Charnprecharut, Veeraphon;Phaitoonwattanakij, Kitti;Tiacharoen, Somporn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.999-1004
    • /
    • 2005
  • An algorithm for a hybrid controller consists of a sliding mode control part and a fuzzy logic part which ar purposely for nonlinear systems. The sliding mode part of the solution is based on "eigenvalue/vector"-type controller is used as the backstepping approach for tracking errors. The fuzzy logic part is a Mamdani fuzzy model. This is designed by applying sliding mode control (SMC) method to the dynamic model. The main objective is to keep the update dynamics in a stable region by used SMC. After that the plant behavior is presented to train procedure of adaptive neuro-fuzzy inference systems (ANFIS). ANFIS architecture is determined and the relevant formulation for the approach is given. Using the error (e) and rate of error (de), occur due to the difference between the desired output value (yd) and the actual output value (y) of the system. A dynamic adaptation law is proposed and proved the particularly chosen form of the adaptation strategy. Subsequently VSC creates a sliding mode in the plant behavior while the parameters of the controller are also in a sliding mode (stable trainer). This study considers the ANFIS structure with first order Sugeno model containing nine rules. Bell shaped membership functions with product inference rule are used at the fuzzification level. Finally the Mamdani fuzzy logic which is depends on adaptive neuro-fuzzy inference systems structure designed. At the transferable stage from ANFIS to Mamdani fuzzy model is adjusted for the membership function of the input value (e, de) and the actual output value (y) of the system could be changed to trapezoidal and triangular functions through tuning the parameters of the membership functions and rules base. These help adjust the contributions of both fuzzy control and variable structure control to the entire control value. The application example, control of a mass-damper system is considered. The simulation has been done using MATLAB. Three cases of the controller will be considered: for backstepping sliding-mode controller, for hybrid controller, and for adaptive backstepping sliding-mode controller. A numerical example is simulated to verify the performances of the proposed control strategy, and the simulation results show that the controller designed is more effective than the adaptive backstepping sliding mode controller.

  • PDF

Toxicokinetics of paraquat in Korean patients with acute poisoning

  • Kim, Hak-Jae;Kim, Hyung-Ki;Lee, Hwayoung;Bae, Jun-Seok;Kown, Jun-Tack;Gil, Hyo-Wook;Hong, Sae-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제20권1호
    • /
    • pp.35-39
    • /
    • 2016
  • To conduct a kinetic study of paraquat (PQ), we investigated 9 patients with acute PQ intoxication. All of them ingested more than 20 ml of undiluted PQ herbicide to commit suicide and arrived at our hospital early, not later than 7 h after PQ ingestion. The urine dithionite test for PQ in all of the nine patients was strongly positive at emergency room. Blood samples were obtained every 30 min for the first 2~3 h and then every 1 or 2 h, as long as the clinical progression was stable among the patients for 30 h after PQ ingestion. The area under the plasma concentration-time curve ($AUC_{inf}$), which was extrapolated to infinity, was calculated using the trapezoidal rule. Toxicokinetic parameters, such as the terminal elimination half-life, apparent oral clearance, and apparent volume of distribution ($V_d/F$) were calculated. The maximum PQ concentration ($C_{max}$) and the time to reach maximum PQ concentration ($T_{max}$) were also obtained. Plasma PQ concentrations in nine patients were well described by a bi-exponential curve with a mean terminal elimination half-life of $13.1{\pm}6.8h$. $C_{max}$ and $AUC_{inf}$ were $20.8{\pm}25.7mg/l$ and $172.5{\pm}160.3h{\cdot}mg/l$, respectively. Apparent volume of distribution and apparent oral clearance were $50.9{\pm}61.3l/kg$ and $173.4{\pm}111.2l/h$, respectively. There were a significant correlation (r=0.84; p<0.05) between the PQ amount ingested and $C_{max}$. $AUC_{inf}$ also showed a significant correlation (r=0.83; p<0.05) with the PQ amount ingested. These correlations provide evidence that PQ has dose-linear toxicokinetic characteristics.

메바코 정 (로바스타틴 20 mg)에 대한 로바로드 정의 생물학적 동등성 (Bioequivalence of Lovaload Tablet to Mevacor Tablet (Lovastatin 20 mg))

  • 송우헌;김정민;조성완;김재현;임종래;신희종;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제28권4호
    • /
    • pp.283-288
    • /
    • 1998
  • Lovastatin, one of the potent cholesterol-lowering agents, is an inactive lactone prodrug which is metabolized to its active open acid, lovastatin acid (LVA). Bioequivalence study of two lovastatin preparations, the test drug ($Mevacor^{\circledR}$: Chungwae Pharmaceutical Co., Ltd.) and the reference drug ($Lovaload^{\circledR}$: Chong Kun Dang Pharmaceutical Co., Ltd.), was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Fourteen healthy male volunteers, $23.9{\pm}3.9$ years old and $67.6{\pm}8.0$ kg of body weight in average, were divided randomly into two groups and administered the drug orally at the dose of 160 mg as lovastatin in a $2{\times}2$ crossover study. Plasma concentrations of lovastatin acid were analysed by HPLC method for 12 hr after administration. The extent of bioavailability was obtained from the plasma concentration-time profiles of total lovastatin acid after alkaline hydrolysis of the plasma samples. By alkaline hydrolysis, trace amounts of unmetabolized lovastatin were converted to lovastatin acid. The $AUC_{0-12hr}$ was calculated by the linear trapezoidal rule method. The $C_{max}$ and $T_{max}$ were compiled directly from the plasma drug concentration-time data. Student's t-test indicated no significant differences between the formulations in these parameters. Analysis of variance (ANOVA) revealed that there were no differences in AUC, $C_{max}$, and $T_{max}$ between the formulations. The apparent differences between the formulations were far less than 20% (e.g., 7.07, 5.77 and 1.18% for AUC, $C_{max}$, and $T_{max}$, respectively). Minimum detectable differences(%) between the formulations at ${\alpha}=0.05$ and $1-{\beta}=0.8$ were less than 20% (e.g., 17.2, 15.1, and 15.9% for AUC, Cmax, and Tmax, respectively). The 90% confidence intervals for these parameters were also within ${\pm}20%$ (e.g.. $-5.20{\sim}19.3$, $-5.00{\sim}16.5$, and $-10.2{\sim}12.5%$ for AUC, $C_{max}$, and $T_{max}$, respectively). These results satisfied the bioequivalence criteria of KFDA guidelines, indicating that the two formulations of lovastatin were bioequivalent.

  • PDF

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권5호
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.

박사르®정 4 밀리그램(라시디핀 4 mg)에 대한 라니디엠®정 4 밀리그램의 생물학적동등성 (Bioequivalence of LANIDIEM® Tablet 4 mg to Vaxar® Tablet 4 mg(Lacidipine 4 mg))

  • 이윤영;김혜진;나숙희;조경희;장문선;박영준;이희주
    • Journal of Pharmaceutical Investigation
    • /
    • 제40권2호
    • /
    • pp.125-131
    • /
    • 2010
  • A bioequivalence study of LANIDIEM$^{(R)}$ tablet 4 mg (Samil. Co., Ltd.) to Vaxar$^{(R)}$ tablet 4 mg (GlaxoSmithKline Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Forty healthy male Korean volunteers were enrolled in the study and thirty six volunteers completed the study according to the protocol. Thirty six volunteers received each medicine at the lacidipine dose of 4 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of lacidipine were monitored by a high performance liquid chromatography - tandem mass spectrometry (LC-MS/MS) for over a period of 24 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for LANIDIEM$^{(R)}$/Vaxar$^{(R)}$ were log 0.8102~log 1.0417 and log 0.8493~log 1.1439, respectively. These values were within the acceptable bioequivalence intervals of log 0.80~log 1.25. Thus, our study demonstrated the bioequivalence of LANIDIEM$^{(R)}$ tablet 4 mg and Vaxar$^{(R)}$ tablet 4 mg with respect to the rate and extent of absorption.

Bioequivalence of Cholicerin Soft Capsule to Gliatilin Soft Capsule (Choline Alphoscerate 400 mg)

  • Kang, Hyun-Ah;Kim, Se-Mi;Kang, Seung-Rae;Kang, Min-Sun;Lee, Sang-No;Kwon, In-Ho;Yoo, Hee-Doo;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제40권2호
    • /
    • pp.109-115
    • /
    • 2010
  • The purpose of the present study was to evaluate the bioequivalence of two choline alphoscerate soft capsules, Gliatilin soft capsule (Daewoong Pharmaceuticals Co., Ltd.) and Cholicerin soft capsule (Sam Chun Dang Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Serum concentrations of choline after oral administration of choline alphoscerate were determined using a validated LC/MS/MS method. This method showed linear response over the concentration range of 0.5-20 ${\mu}g$/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 100 ${\mu}L$ of serum was 0.5 ${\mu}g$/mL which was sensitive enough for pharmacokinetic studies. Thirty six healthy male Korean volunteers received each medicine at the choline alphoscerate dose of 1200 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Blood samples were taken at predetermined time intervals up to 8 hr. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 8 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Cholicerin/Gliatilin were log0.9998-log1.1172 and log0.9938-1.0944, respectively. These values were within the acceptable bioequivalence intervals of log0.80-log1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Cholicerin soft capsule and Gliatilin soft capsule are bioequivalent.

Bioequivalence Evaluation of Two Brands of Zolpidem Tartrate 10 mg Tablets(Zanilo and Stilnox) in Healthy Male Volunteers

  • Ryu, Ju-Hee;Lee, Heon-Woo;Lee, Hyun-Su;Kang, Il-Mo;Seo, Ji-Hyung;Kang, Jin-Yang;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권5호
    • /
    • pp.343-348
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two zolpidem tartrate tablets, Stilnox tablet(Sanofi-aventis Korea, reference product) and Zanilo tablet(ChoDang Pharm Co., Ltd., Korea, test product), according to the guidelines of Korea Food and Drug Administration(KFDA). After adding an internal standard(cimetropium), 250 ${\mu}L$ plasma samples were extracted using 1.3 mL of ethyl acetate. Extracted compounds were analyzed by HPLC with triple-quadrupole mass spectrometry. This method for determination of zolpidem is proved accurate and reproducible with the limit of quantitation of 1 ng/mL in human plasma. Twenty-four healthy male Korean volunteers received each medicine at the zolpidem tartrate dose of 10 mg in a $2{\times}2$ crossover study. There was one-week washout period between the doses. Plasma concentrations of zolpidem were monitored for over a period of 8 hr after the administration. $AUC_{0-t}$(the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{0-t}$ and $C_{max}$. No significant sequence effect was found for all of the bio-availability parameters indicating that the crossover design was properly performed. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25(e.g., log 0.92-log 1.06 for $AUC_{0-t}$, log 0.96-log 1.13 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that Zanilo tablet is bioequivalent to Stilnox tablet.