• 제목/요약/키워드: Transverse overturning

검색결과 4건 처리시간 0.018초

Analysis of Static Lateral Stability Using Mathematical Simulations for 3-Axis Tractor-Baler System

  • Hong, Sungha;Lee, Kyouseung;Kang, Daein;Park, Wonyeop
    • Journal of Biosystems Engineering
    • /
    • 제42권2호
    • /
    • pp.86-97
    • /
    • 2017
  • Purpose: This study aims to evaluate the applicability of a tractor-baler system equipped with a newly developed round baler by conducting stability analyses via static-state mathematical simulations and verification experiments for the tractor equipped with a loader. Methods: The centers of gravity of the tractor and baler were calculated to analyze the transverse overturning of the system. This overturning of the system was analyzed by applying mathematical equations presented in previous research and comparing the results with those obtained by the newly developed mathematical simulation. For the case of the tractor equipped with a loader, mathematical simulation results and experimental values from verification experiments were compared and verified. Results: The center of gravity of the system became lower after the baler was attached to the tractor and the angle of transverse overturning of the system steadily increased or decreased as the deflection angle increased or decreased between $0^{\circ}$ and $180^{\circ}$ on the same gradient. In the results of the simulations performed by applying mathematical equations from previous research, right transverse overturning occurred when the tilt angle was at least $19.5^{\circ}$ and the range of deflection angles was from $82^{\circ}$ to $262^{\circ}$ in counter clockwise. Additionally, left transverse overturning also occurred at tilt angles of at least $19.5^{\circ}$ and the range of deflection angles was from $259^{\circ}$ to $79^{\circ}$ in counter clockwise. Under the $0^{\circ}$ deflection angle condition, in simulations of the tractor equipped with a loader, transverse overturning occurred at $17.9^{\circ}$, which is a 2.3% change from the results of the verification experiment ($17.5^{\circ}$). The simulations applied the center of gravity and the correlations between the tilt angles, formed by individual wheel ground contact points excluding wheel radius and hinge point height, which cannot be easily measured, for the convenient use of mathematical equations. The results indicated that both left and right transverse overturning occurred at $19.5^{\circ}$. Conclusions: The transverse overturning stability evaluation of the system, conducted via mathematical equation modeling, was stable enough to replace the mathematical equations proposed by previous researchers. The verification experiments and their results indicated that the system is workable at $12^{\circ}$, which is the tolerance limit for agricultural machines on the sloped lands in South Korea, and $15^{\circ}$, which is the tolerance limit for agricultural machines on the sloped grasslands of hay in Japan.

저층부에 약층과 비틀림 비정형성을 가진 고층 비정형 RC벽식 구조물의 지진응답 (Seismic Response of a High-Rise RC Bearing-Wall Structure with Irregularities of Weak Story and Torsion at Bottom Stories)

  • 이한선;고동우
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.81-91
    • /
    • 2003
  • 최근 우리나라의 대도시에서는 주거와 상업기능을 동시에 갖는 복합용도의 건축물이 많이 건설되고 있는데, 이러한 건물은 대부분 하부골조에서 연층, 약층 또는 비틀림 비정형을 띠게 된다. 본 논문의 목적은 이러한 건물의 지진응답을 실험을 통해 관찰하는 것으로서 1:12 축소모델의 진동대 실험을 통해 다음과 같은 결론에 이르렀다. 1) 구조물의 불확실성으로 인한 우발비틀림을 예측하는 것은 정적해석에 의한 방법보다 동적해석에 의한 방법이 더 타당하였다. 2) 횡운동과 비틀림운동이 연관되어 있을 때, 전도모멘트는 지진방향 뿐만 아니라 지진방향에 수직인 방향으로도 상당부분 작용하였으며, 일반적인 해석프로그램에서 수행하는 모드해석법으로는 이와 같은 거동을 예측하기에 부적절하였다. 3) 모드형상과 BST 다이아그램을 통해 대상구조물과 같은 건물의 주요 진동모드와 파괴양상을 쉽게 예측할 수 있었다.

산지하천의 스텝-풀 연속체 복원설계 (Restoration design of step-pool sequence in mountain streams)

  • 김기흥
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.29-43
    • /
    • 2020
  • 본 연구의 목적은 하천복원에 스텝-풀 연속체를 적용하기 위해 기존 연구결과에서 스텝-풀의 기하구조, 형성 과정, 수리 기능, 복원 및 생태 기능과 관련된 사항을 검토하여 설계기준 및 세부설계 모델을 제시하는 것이다. 분석 및 검토결과를 바탕으로 스텝 간격과 하폭의 비, 단위스텝경사와 하상경사의 비, 및 스텝 높이와 입경 비로서 스텝-풀의 구조 및 규모에 대한 설계기준을 제시하였고, 스텝의 구조적 안정성 확보를 위해서는 키스톤 이론을 근거로 전도에 대한 안정성 해석방법을 설계기준으로 제시하였다. 세부설계 개념으로서 스텝-풀의 평면, 종단 및 횡단 구성에 키스톤과 아치스톤에 대한 겹침구조를 적용한 배치 모델을 제안하였다.

고층 철근콘크리트 건축구조모델의 지진응답에 대한 해석적 모사 (Analytical Simulation of the Seismic Response of a High-Rise RC Building Model)

  • 이한선;이정재;정동욱
    • 한국지진공학회논문집
    • /
    • 제12권5호
    • /
    • pp.1-10
    • /
    • 2008
  • Taft N21E 지진파를 사용하여 1:12 축소된 모델로 여러번의 진동대 실험을 저층부 2개층에 비틀림과 연층을 가지는 17층 고층 철근콘크리트 건물에 대해 지진 거동을 조사하기 위해 수행했었다. 이 거동의 주요 특징은 (1) 연약 골조가 거대한 비탄성 변형을 받은 후 변형이나 비틀림에서 비틀림 모드까지 현저한 진동의 갑작스런 변화, (2) 이러한 모드 변화에 따른 비틀림 강성의 갑작스런 증가, (3) 비틀림 모드에서 월의 요곡(warping) 거동, 그리고 (4) 진동대 거동의 반대 방향에만 생기는 전도모멘트 양상을 보여주었다. 본 연구에서는 이러한 성과를 Perform3D라는 비선형 해석 프로그램을 사용하여 위 특성을 모사하기 위해 노력하였다. 이 소프트웨어에서 가용한 비선형 모델과 함께 그의 장점과 단점을 해석 및 실험 결과의 비교를 통해 제시하였다.