• Title/Summary/Keyword: Transmitting and receiving circuit

Search Result 43, Processing Time 0.023 seconds

Manufacture of Custom IC and System for Multi-channel Biotelemeter (다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작)

  • 서희돈;박종대
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

Automated Wireless Recharging for Small UAVs

  • Jung, Sunghun;Ariyur, Kartik B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.588-600
    • /
    • 2017
  • We develop a wireless, contact free power transfer mechanism that is safer than the direct metallic contact and robust to imperfect alignment on landing at the base station. A magnetic field is created using inductors on both the transmitting and receiving sides. We use the inductive wireless recharging to increase autonomy and decrease the sensor interference by reducing the inductor loop size. By locating four independent small receiver loops and corresponding four circuits around the quadrotor UAV, we can increase safety from circuit malfunctions in comparison to the use of just one loop. On the base station, four folding robotic bars are used to realign the receiver loops over the transmitter loops. After adequate recharging as measured by battery voltages or power consumption at the bae station, the UAV sends a signal to the base station to open the robotic bars and takes off once freed from the robotic bars.

Development of Optical Fiber Displacement Sensor for Non-contact Vibration Measurement in the High Speed Rotation System (고속회전체의 진동 측정용 비접촉 광섬유 변위센서 개발)

  • Lee, Kee-Seok;Hong, Jun-Hee;Shin, Woo-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.50-56
    • /
    • 2005
  • This paper is described a development of an optical fiber displacement sensor. The optical fiber sensor using an intensity modulated measures the displacement between target and sensor. A prototype sensor is composed of a transmitting part, a receiving part and a signal processing circuit. The experiment was conducted not only the sensor performance but also factors that affect intensity. The main performance of this sensor is resolution of 0.37um and the non-linearity $0.7\%$ FS and the dynamic bandwidth of about 6.3kHz. As a result of rotation test, the prototype sensor showed an equivalent performance to a commercial eddy current sensor.

Focal Length Control of Line-focus Ultrasonic Transducer Using Bimorph-type Bending Actuator (바이몰프형 밴딩 액츄에이터를 이용한 선집속형 초음파 트랜스듀서의 초점 거리 제어)

  • 채민구;하강열;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.202-207
    • /
    • 2003
  • For medical ultrasonic transducer, phase-weighting method has been used for controlling focal length with electric circuit at each vibrating element. However, the electric circuit is complex as the number of vibrating elements is increased. In this paper, we fabricated line-focus transducer with a bimorph-type piezoelectric actuator. The polyvinylidene fluoride (PVDF) piezoelectric type polymer film is used for transmitting and receiving of ultrasonic signal. Using this transducer, focal length of the transducer can be controlled mechanically by changing voltage of the actuator. It is confirmed that focal length of the transducer can be controlled in range of 1095 to radius of curvature.

Development of Intelligent Self-alarming EAS System Using Dual-band Wireless Communication (듀얼밴드 무선통신기술을 이용한 지능형 자명식(自鳴式) 도난방지시스템 개발)

  • Choi, Yeon-Suk;Kim, Keum-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1616-1626
    • /
    • 2010
  • This paper will show how self-alarming EAS(Electronic Article Surveillance) system can improve its receiving performance of magnetic field signal and reduce false alarm using dual-band wireless communication. Our research improved the receiving performance and the areas of recognition of magnetic signal through the change of VLF receiving circuit and alarm transmitting method. In addition, we verified the reduction of false alarm by improvement of integrity and distance between tag and receiver through experiment. Thanks to our research, we can build the high performance and economical EAS with low false alarm on the multi gate store.

Performance Measurement of the Wireless Charging Devices Using Eletromagnetic Induction Techniques (전자기유도방식을 이용한 무선 충전 기기의 구현 및 성능 측정)

  • Ryu, Daun;Kim, Young Hyun;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • This paper presented the design of wireless power transfer (WPT) system using electromagnetic induction techniques and analysed WPT efficiency. Also, we presented the optimum coil condition by measuring the efficiency variation according to some receiving coil parameter changes. Voltage change is measured by receiving coil position for the designed transmitting and receiving circuit. Voltage change according to inductance variation at the same position and charging time are compared at the same environment by using a developed application program to realize an optimum WPT system. Developed wireless power transfer system using electromagnetic induction techniques uses 125 kHz. It takes 16 minutes by using wired charger, and 23 minutes by using wireless charger for charging from 50% to 60% charging status.

A Study on Design and Implementation of Hangul-NAVTEX Simulator (한글 NAVTEX시뮬레이터 설계 및 구현에 관한 연구)

  • 이헌택;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.819-830
    • /
    • 1999
  • NAVTEX system is an international automated direct-printing service, broadcast on 5181kHz and 490kHz, for the promulgation of navigational and meteorological warnings and urgent information to ships. With our government's adoption of the international convention for SAR(Search and Rescue) in 1993, various trials for the installation of NAVTEX system have been executed by the government committee, relating laboratory and experts. An important consideration of the installation for NAVTEX system is the availability that could broadcast messages written in korean letter. Also, the receiver which can process the signal demodulated from the two frequencies, 518kHz and 490kHz, should be developed and supplied in domestic. In this paper, the code table and algorithm for conversions between NAVTEX characters and Korean Letters are studied, and signal processing techniques of code conversion are developed. Circuit design and implementation of the NAVTEX simulator using the Direct Digital Synthesizer are discussed, code conversion algorithm and signal processing technique of the NAVTEX transmission are programmed in its circuits. For evaluating the its functional characteristics, receiving module which has I-Q channel structure is designed. From the measurements of simulator, the characteristics show the frequency stability of the $(\pm)2Hz$ and Spurious free dynamic range is -63dBc. And the simulator can generate simultaneously wanted signal and several interfere signals. So, its capability is valuable for designers of the transmitting system and NAVTEX receiver, for provider as testing facilities of the type approval.

  • PDF

Technological Trends of C-/X-/Ku-band GaN Monolithic Microwave Integrated Circuit for Next-Generation Radar Applications (차세대 레이더용 C-/X-/Ku-대역 GaN 집적회로 기술 동향)

  • Ahn, H.K.;Lee, S.H.;Kim, S.I.;Noh, Y.S.;Chang, S.J.;Jung, H.U.;Lim, J.W.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.5
    • /
    • pp.11-21
    • /
    • 2022
  • GaN (Gallium-Nitride) is a promising candidate material in various radio frequency applications due to its inherent properties including wide bandgap, high carrier concentration, and high electron mobility/saturation velocity. Notably, AlGaN/GaN heterostructure field effect transistor exhibits high operating voltage and high power-density/power at high frequency. In next-generation radar systems, GaN power transistors and monolithic microwave integrated circuits (MMICs) are significant components of transmitting and receiving modules. In this paper, we introduce technological trends for C-/X-/Ku-band GaN MMICs including power amplifiers, low noise amplifiers and switch MMICs, focusing on the status of GaN MMIC fabrication technology and GaN foundry service. Additionally, we review the research for the localization of C-/X-/Ku-band GaN MMICs using in-house GaN transistor and MMIC fabrication technology. We also discuss the results of C-/X-/Ku-band GaN MMICs developed at Defense Materials and Components Convergence Research Department in ETRI.

Design of a High Power Frequency Tuneable Resonator for Wireless Power Transfer (무선 전력 전송용 고출력 주파수 가변 공진기 설계)

  • Park, Jaesu;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.352-355
    • /
    • 2013
  • In this paper, a high power tuneable resonator for a wireless power transfer system based on magnetic resonance is proposed. A spiral structure is used for a self-resonant coil and tuneable trimmer capacitors are added at the edges of resonant coils such that the frequency can be easily tuned. 3D simulation tools and equivalent circuit modeling method are used for predicting self-resonant frequency and scattering parameters according to the change of capacitor values. From the measurement of the prototype WPT system, the resonant frequency could be controlled from 3.0 MHz to 4.5 MHz and the transmission efficiency way over 50 % when the distance between transmitting coil and receiving coil was 160 mm.

Development of Ultrasound Sector B-Scanner(I)-Front End Hardware Part- (초음파 섹터 B-스캐너의 개발(I)-프론트 엔드 부분-)

  • 권성재;박종철
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.59-66
    • /
    • 1986
  • A prototype ultrasound sector B-scanner has been developed where the front-end hardware refers to all the necessary circuits for transmitting the ultrasound pulses into the human body and receiving the reflected echo signals from it. The front-end hardware can generally be divided into three parts, i.e., a pulse generator for insonification, a receiver which is responsible for processing of low-level analog signals, and a steering controller for driving the mechanical sector probe whose functions and design concepts are described in this paper. The front-end hardware is implemented which incorporates the following features: improvement of the axial resolution using a circuit which reduces the ring-down time, flexibility of generating time-gain compensation curve, and adoption of a one-chip microcomputer for generating the rate pulses based on the sensor output waveforms.

  • PDF