• 제목/요약/키워드: Transmitted light

검색결과 295건 처리시간 0.025초

Simulation Study of an e-Beam Addressed Liquid Crystal Display for Projection

  • Zhou, Fushan;Yang, Deng-Ke;Molitor, R.J.
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.8-12
    • /
    • 2002
  • We have carried out a simulation study on an e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display and the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

저압 분사시 캐비테이션에 의한 단공 노즐의 미립화 향상 (The Enhacned Atomization of Single Hole Nozzle by Cavitation at The Low Pressure Injection)

  • 손종원;차건종;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.952-957
    • /
    • 2001
  • The objectives of this investigation were to obtain an excellent spray by cavitation under the low injection pressure. When cavitation occurs in the nozzle hole, the atomization of the liquid jet enhanced considerably. In this experiments, a acrylic nozzle made the gap and installed the bypass in the nozzle hole was used to enhance the atomization of the liquid jet at the low injection pressure. The liquid flow in the nozzle hole was photographed by a transmitted light using a micro flash. The spray angle was measured macroscope images of PMAS and the Sauter mean diameter was measured PDA system. To measure the pressure of the nozzle hole, pressure transducer was used. The results of this study indicated that enhanced atomization of the liquid jet at the low injection pressure was obtained by making the gap and installing the bypass at the single hole nozzle.

  • PDF

장주기 격자를 이용한 광섬유 레이저센서의 파장변화 측정 (Laser sensor wavelength interrogation using a long-period fiber grating)

  • 송민호;이상배;최상삼;남희;이병호
    • 전자공학회논문지D
    • /
    • 제34D권12호
    • /
    • pp.83-88
    • /
    • 1997
  • We present a fiber laser sensor that uses a fiber grating as a strain sensor head and an end-reflector of the laser cavity. A passive wavelength. The long-period grating band-rejection filter showed a wide usable filter wavelength range of about 25 nm, and the intensity of transmitted light increased by 16% for 1nm sensor wavelength shift in trhe measurement range.

  • PDF

Modeling an e-Beam Addressed Liquid Crystal Projection Display

  • Yang, Deng-Ke;Zhou, Fushan;Molitor, R.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.930-932
    • /
    • 2002
  • We have carried a theoretical study on e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display. We also studied the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

  • PDF

오리피스 형상에 따른 단공 노즐의 내부 가시화와 분무 특성 (The Effects of the Orifice Shapes on the Internal Visualization and The Spray Characteristics of the Single Hole Nozzle)

  • 손종원;차건종;김덕줄
    • 한국분무공학회지
    • /
    • 제7권1호
    • /
    • pp.36-42
    • /
    • 2002
  • The objective of this investigation was to obtain an excellent spray at the low injection pressure. When cavitation occurred in the nozzle hole the atomization of the liquid jet enhanced considerably. In this experiments, a acrylic nozzle which was installed the gap and installed the bypass in the nozzle hole was used to enhance the atomization of the liquid jet at the few injection pressure. The liquid flow in the nozzle hole was photographed by a transmitted light using a micro flash. The spray angle was measured by macroscope images of PMAS and the Sauter mean diameter was measured by PDA system. The pressure of the notate hole was measured by pressure transducer. It was found that enhanced atomization of the liquid jet at the low injection pressure was obtained by installing the gap and the bypass at the single hole nozzle.

  • PDF

Objective Measurement of Water Repellency of Fabric Using Image Analysis (I) - Methodology of Image Processing -

  • Jeong Young Jin;Jang Jinho
    • Fibers and Polymers
    • /
    • 제6권2호
    • /
    • pp.162-168
    • /
    • 2005
  • A methodology for the objective evaluation of water repellency is studied using image analysis of the sprayed pattern on woven fabrics according to a standard spray test (AATCC Test Method 22-2001). The wet area ratio obtained from the spray standard test ranking is found to be exponentially related with its water repellency rating. Mean filtering is used to remove the effect of weave texture and the transmitted light through interyarn spaces. The ring frame of the instrument and wet region are recognized using Otsu thresholding technique. And Hough transform and outline operation are used to obtain the size and position of the ring frame. The objective assessment of the water repellency using image processing can reduce unnecessary confusion in the subjective determination of the water repellency.

투과광 스펙트럼 측정법을 이용한 링레이저 공진기의 광학적 정렬 (Alignment of a ring laser cavity by using the cavity transmission spectrum control method)

  • 전형욱;최용진;이기홍;신상훈;이혁수;손정영
    • 한국광학회지
    • /
    • 제8권6호
    • /
    • pp.456-460
    • /
    • 1997
  • 링 레이저 공진기를 광학적으로 정렬하는 방법은 여러 가지가 있지만, 투과광 스펙트럼 측정법(cavity transmission spectrum control)은 측정이 매우 간단하고 공진기의 손실을 측정하면서 동시에 정렬을 할 수 있는 장점이 있다. 투과광 스펙트럼 측정법을 이용한 공진기의 광학적 정렬 장치를 구성하여, 레이저 자이로스코프에 사용할 링형 공진기에 모두 네 개의 반사경을 정렬 부착시켰으며, 동시에 정렬한 공진기의 내부 손실 값을 측정했다. 그 결과 최소 내부 손실은 0.98%였으며, 네 개의 반사경에 대한 총 반사 계수는 99.02%로 계산된다.

  • PDF

빛을 이용한 음성통신시스템 특성에 관한 연구 (Study on the Characteristics of Voice Communication System using Lights)

  • 윤만영;신종순
    • 한국인쇄학회지
    • /
    • 제23권2호
    • /
    • pp.15-23
    • /
    • 2005
  • This analog communication system overcomes a limit of the digital communication that used an electric power line, and shows a strong characteristic by decrease of impedance along a load or surge-voltage and the same noise. this system is to detect an sound signal added to light through an photo-sensor and a filter circuit. And a signal detected in this way is transmitted to sound through a speaker of an earphone again.

  • PDF

북한 함경북도 일부 주민의 기생충 감염 실태 조사 (Status of intestinal helminthic infections in some residents of North Korea)

  • 이순옥;신성화;최민호;윤희원;홍성태
    • 한국건강관리협회지
    • /
    • 제3권2호
    • /
    • pp.172-180
    • /
    • 2005
  • A small scale survey on intestinal parasitic infections was investigated by subjecting residents of North Korea to recommend a plausible control strategy. The Kato-Katz method was applied to 235 residents in a borderline city and 46 in a refugee camp in borderline China. Only eggs of Ascaris and Trichuris were detected in 41.1% and 37.6% respectively but most of them were light infected. Females were infected in 61.2% while 53.1% males were egg positive. By age, residents in their 30s showed highest egg positive rates. The survey confirmed high prevalence of soil-transmitted intestinal nematodes in rural areas in North Korea It is recommended to implement mass chemotherapy for al residents with a part sample examination in rural areas, North Korea.

  • PDF

Development of an Equipment for Monitoring Current and Voltage on a Power Transmission Line

  • K. Kuwanami;E.Jishiuama;T Matsuda;I.Oota;H.Kuribayashi;N. Ueda;Ha, S.yata
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.233-236
    • /
    • 2000
  • A portable equipment that measures a current and voltage waveform of power transmission lines is pro-posed. In the equipment, the current and voltage, respectively, are detected by a loop coil and a capacitor clamped around the power lines. The detected data is transmitted by an FM wave to the receiver on the ground station. Since the receiver is isolated from the power lines, we do not require high potential insulators for the measurement of current and voltage. The proposed equipment is therefore, small-sized, light, and low in the cost of production. Experimental results presented here show that the equipment can monitor the current flowing in single wire over a ground plane and the potential of the wire.

  • PDF