• Title/Summary/Keyword: Transmitted dose

Search Result 57, Processing Time 0.03 seconds

Trial of Computer Simulation of Image Reconstruction from Incomplete Data for New CT with Reduced Exposure

  • Hayakawa, Yoshinori;Furuya, Toshimitsu;Sakakibara, Norifumi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.382-384
    • /
    • 2002
  • Filtered-Back-Projection technique is used in X-ray CT image reconstruction. This requires X-ray transmission data from all directions. As the transverse cross-section of the body is approximately 50 cm, transmitted X-rays in this direction are strongly attenuated. If X-ray transmission data in this direction is avoided, exposure to the patients seems to be reduced one 20th of usual value. Some alternative method has to be found for clinically sufficient image quality. New methods are under development and tentative results are reported that utilizes the principle of superposition.

  • PDF

X-Ray Spectrum Modulation for Mammography (X-선 스펙트럼 변조 기술 연구)

  • Kim, Gwang-Hyeon;Kim, Gyeong-Rak;O, Chang-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.600-603
    • /
    • 2003
  • Energy spectrum modulation of X-ray source in digital mammography has been studied. In this study, we calculated various filtered spectra using the scattering data. Primary spectra were generated by Molybdenum (Mo) and Tungsten (W) targets. The materials of added filters are Molybdenum and Rhodium (Rh) for 40 kVp Mo. primary spectrum, the amounts of photons over whole energy ranges are attenuated to 0.43 with 0.03 mm Mo filter and 0.38 with 0.06 mm Mo filter while the photons of energy ranged from 17 keV to 20 keV. The photons of low energy ranged below 17 keV are considerably attenuated. This effect brings out reducing the scattered radiation and dose to the patient, and enhancing subject contrast in the image. The results show that filtered spectra are not seriously affected by X-ray tube loadability. Because the energy range from 17 keV to 20 keV is directly transmitted although low and high energies are mainly filtered.

  • PDF

Treatment of natural tropical theileriosis with the extract of the plant Peganum harmala

  • Mirzaei, Mohammad
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.4
    • /
    • pp.267-271
    • /
    • 2007
  • Theileria annulata, a protozoan parasite of cattle and domestic buffaloes, is transmitted by ticks of the genus Hyalomma, and causes a disease named Mediterranean or tropical theileriosis. In this research 50 cattle naturally infected with Theileria annulata were treated with the extract of the plant Peganum harmala. The treatment was continued for 5 days, the dose of the extract being 5 mg/kg per day. After the treatment, 39 cattle responded to the treatment and recovered, but 11 did not respond to the treatment and died. The recovery rate of animals treated with the extract of the plant Peganum harmala was 78%.

Volume Change of Spiral Computed Tomography due to the Changed in the Parameters (파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화)

  • Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2013
  • This study examined the change of artifact volume by analyzing the level of image change associated with the setting of threshold through 3D imaging in scan parameter(slice thickness and helical pitch) and 3D image reconstruction to explore whether the presence of pathology was fully distinguished when CT was taken by lower dose than the existent dose to reduce exposure. Furthermore, this study attempted to investigate Scan Parameter acceptable in CT to reduce exposure dose. For materials and methods, silicon was used to produce samples. Five spherical samples were produced at 10-millimeter intervals(50, 40, 30, 20, and 10 mm) in diameter and were fixed at 120 Kvp of tube voltage and 50 mA of tube current. Varied slab thickness((1.0, 2.0, 3.0, 5.0, and 7.0mm) and Helical Pitch(1.5, 2.0, 3.0) were scanned. The image at an interval of 1.0, 2.0, 3.0, 5.0, and 7.0mm was transmitted to the workstation. Threshold(-200, -50, 50 ~ 1,000) was changed using the volume rendering technique, 3D image was reconstructed, and artifact volume was measured. In conclusion, 1.5 of Helical Pitch showed the least change of volume and 3.0 of helical pitch showed the greatest reduction of volume change. The experiment suggested that as slice thickness was increased, artifact volume was decreased more than actual measurement. Furthermore, in the 3D image reconstruction, when the range of threshold was set as -200 ~1,000, artifact volume was changed the least. Based on the results, it is expected to have an effect of reducing exposure dose.

Evaluation of the Shielding Effect of Polyvinyl Chloride (PVC) on Low-dose Blending Radiation Energy (폴리 염화 비닐(PVC)의 저선량 융합 방사선에너지에 대한 차폐 효과 평가)

  • Kim, Seon-Chil;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.129-134
    • /
    • 2019
  • PVC was chosen as a plastic product that can cope with lead, a radiation shielding material that is widely used in medical institutions. In addition to radiation shielding clothing, we want to evaluate whether it can be used as a medical device component and industrial shielding material in low dose areas. Commercial PVC has a density of 3.68 g/㎠ and can be positively expected sufficient shielding effect in certain radiation areas such as material flexibility and economy efficiency, and can be transformed into various forms and used as a lightweight shielding wall. The shielding performance was tested by adjusting the thickness of 5 sheets of 3mm PVC in the range of medical radiation used for clinical examination in medical institutions. Shielding performance against effective energy was evaluated based on tube radiation voltage of medical radiation. The thicker the PVC, the lower the tube voltage and the lower the effective energy, the greater the shielding effect. The shielding effect was 70% at 12mm thickness and 80kVp tube voltage. Therefore, the shielding effect of PVC material has a high dependence of thickness. In the future, continuous research is needed to make thin and light eco-friendly products while improving shielding performance.

A Case of Congenital Partial Nephrogenic Diabetes Insipidus (선천성 부분 신성 요붕증 1례)

  • Mo, Eun Ha;Nam, In Hye;Chung, Min Ja;Yu, Jae Hong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.902-905
    • /
    • 2002
  • The most common form of genetic nephrogenic diabetes insipidus(NDI), a rare inherited disorder, is congenital and is transmitted in an X-linked recessive mode. It is refractory to the antidiuretic effect of normal to moderately increased levels of plasma arginine vasopressin(AVP) but, in some cases, may respond to high levels of the hormone or its analogue, deamino-D-arginine vasopressin(DDAVP). X-linked congenital NDI has now been linked to over 128 different mutations in diverse coding regions of the AVP receptor 2(AVPR2) gene. The functional effects of these mutations vary from complete loss of responsiveness to a simple shift to the right in the dose response curve. We report a case of congenital partial NDI, with transversion of A to G at codon 280 of the AVPR2 gene, resulting in a subsequent change of amino acid from tyrosine to cysteine, and that has been effective with hydrochlorothiazide and high dose of DDAVP.

A Study on Electron Beam Dosimetry for Chest Wall Irradiation (흉곽(胸廓)의 전자선(電子線) 조사시(照射時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1983
  • To obtain 7 MeV electron beam which is suitable for treatment of the chest wall after radical of modified radical mastectomy, the authors reduced the energy of electron beam by means by Lucite plate inserted in the beam. To determine the proper thickness of the Lucite plate necessary to reduce the energy of 9 MeV electron beam to 6 MeV, dosimetry was made by using a parallel plate ionization chamber in polystyrene phantom. Separation between two adjacent fields, 7 MeV for chest wall and 12 MeV for internal mammary region, was studied by means of film dosimetry in both polytyrene phantom and Humanoid phantom. The results were as follows. 1. The average energy of 9 MeV electron beam transmitted through the Lucite plate was reduced. Reduction was proportional to the thickness of the Lucite plate in the rate of 1.7 MeV/cm. 2. The proper thickness of the Lucite plate necessary to obtain 6 MeV electron beam from 9 MeV was 1.2 cm. 3. 7 MeV electron beam, 80% dose at 2cm depth, is adequate for treatment of the chest wall. 4. Proper separation between two adjacent electron fields, 7 MeV and 12 MeV, was 5mm on both flat surface and sloping surface to produce uniform dose distribution.

  • PDF

Evaluation of Application of 3D Printing Phantom According to Manufacturing Method (구성 물질에 따른 3D 프린팅 팬텀의 적용 평가)

  • Young Sang Kim;Ju Young Lee;Hoon Hee Park
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.173-181
    • /
    • 2023
  • 3D printing is a technology that can transform and process computerized data obtained through modeling or 3D scanning via CAD. In the medical field, studies on customized 3D printing technology for clinical use or patients and diseases continue. The importance of research on filaments and molding methods is increasing, but research on manufacturing methods and available raw materials is not being actively conducted. In this study, we compare the characteristics of each material according to the manufacturing method of the phantom manufactured with 3D printing technology and evaluate its usefulness. We manufactured phantoms of the same size using poly methyl meta acrylate (PMMA), acrylonitrile butadiene styrene (ABS), and Poly Lactic Acid (PLA) based on the international standard phantom of aluminum step wedge. We used SITEC's radiation generator (DigiRAD-FPC R-1000-150) and compared the shielding rate and line attenuation coefficient through the average after shooting 10 times. As a result, in the case of the measured dose transmitted through each phantom, it was confirmed that the appearance of the dose measured for phantoms decreased linearly as the thickness increased under each condition. The sensitivity also decreased as the steps increased for each phantom and confirmed that it was different depending on the thickness and material. Through this study, we confirmed that 3D printing technology can be usefully used for phantom production in the medical field. If further development of printing technology and studies on various materials are conducted, it is believed that they will contribute to the development of the medical research environment.

Evaluation of Chest Density in Insight Film (Insight film을 이용한 농도측정 평가)

  • Kwon, Lee-Seon;Park, Jang-Hwan;Lim, Oh-Soo;Jung, Kyong-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.17-23
    • /
    • 1992
  • Simple chest radiography is the most frequently performed examination in radiologic practice. However, with transmitted dose through chest which has the problem of wide variations in absorption, conventional Film/Screen Combinations Method make it difficult to delineate lung field mediastinum & cardia portion and subdiaphragmatic structures. In order to overcome this problem, we have been tried several methods as follows. High Kilovoltage Technique, Rare Earth Screen/Wide Lattitude Film, Use of Compensating Filter and Digital Beam Attenuator and recently Insigh System has been developed. In this paper, we'd like to discuss Insight film through apperciation by measuring the difference of contrast. In order to evaluate insight film. We have done experiments using Insight System with Simple Phase, Picker 550. We could get an result which was able to overcome the limitted dynamic range of conventional Film/Screen System remarkably.

  • PDF

A study on performance evaluation of Apron by shielding rate and uniformity (방사선방어용앞치마(Apron)의 차폐율과 균일성 측정을 통한 성능평가 연구)

  • Yoo, Se-Jong;Lim, Chang-seon;Sim, Kyu-ran
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p=0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.