안티몬 차폐시트의 감마선 차폐 성능평가 (Performance Evaluation of Gamma ray Shielding of Antimony Shielding Sheet)

  • 한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.135-140
    • /
    • 2018
  • In this study, the dose of antimony shielding sheet was measured and the shielding rates according to the distance between the radioisotopes and the detector was analyzed according to the type of $^{99m}Tc$, $^{18}F$, $^{201}Tl$, $^{131}I$, $^{123}I$ using the antimony shielding sheet. The detector was used with an inspector. Six sheets of 0.25 mmPb were prepared with 20 cm width and length. Measurement results using $^{99m}Tc$, $^{201}Tl$, and $^{123}I$ showed that as the thickness of the sheet became thicker, the farther the distance from the source to the sheet was, the smaller the transmitted dose amount was measured. It was analyzed that a thickness of 1.50 mm or more was required to obtain a shielding rates of 90% or more. In the experiments of $^{18}F$ and $^{131}I$, the dose value was highest when 0.25 mm sheet was used, and the shielding rates was negative, unlike the results of other radioisotopes. Since $^{201}Tl$ are used when using antimony sheet and $^{18}F$ and $^{131}I$ have no shielding effect, it is thought that it is effective to reduce dose by repeating training and simulation training so that work can be done in a short time.

진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구 (A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography)

  • 최남길;성호진;전주섭;김윤현;성동욱
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.25-34
    • /
    • 2012
  • 본 연구는 진단용 X-선 촬영에서 부가필터 두께에 따라 피폭 선량 및 의료영상저장전송시스템에 저장된 영상을 비교 평가하여 환자에게 가장 적은 방사선 피폭을 주면서 진단에 적절한 영상을 얻을 수 있는 촬영 조건을 알아보고자 하였다. 그 결과 면적선량($mGy{\cdot}cm^2$)과 입사표면선량($mGy$)은 1 mmAl+0.2 mmCu의 부가필터에서 가장 낮은 피폭 선량값을, 그리고 0 mmAl (No Filter)에서 가장 높은 피폭 선량 값을 보였다. 그러나 의료영상저장전송시스템으로 전송된 영상을 수치 해석 소프트웨어(MATLAB)로 구현한 히스토그램 결과 영상의 질에는 크게 영향을 미치지 않았다. 따라서 진단용 X-선 촬영 장치를 이용한 영상의학적 검사에서 영상의 질에 영향을 미치지 않고 피폭선량을 경감할 수 있는 최적의 부가필터를 사용함으로서 환자의 피폭 선량을 예측하고 검사 조건을 조절하는 데 있어 유용하게 이용될 수 있을 것으로 판단되었다.

방사선 방호용 에이프런의 경량화와 차폐능 개선 (Improvement of the shieldability and lightweight of a radiation protective apron)

  • 김영근;장영일;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권1호
    • /
    • pp.45-50
    • /
    • 2003
  • 투시 조영 촬영시 사용되는 방호복의 차폐효율 증가와 경량화는 오랜 시간 연구 대상이 되었다. 이러한 방호복의 질적 향상을 위하여 연구한 결과는 다음과 같다. Apron의 규격인 납당량 0.25 mm에 해당하는 투과선량률은 5.2%로 나타났으며, 시료 Sn, Ni, Ti, Cu의 방사선 차폐 효율은 Sn이 가장 놓게 나타났다. 증착시료 Sn + Pb와 Pb + Sn는 각각 Sn 0.18 mm와 Pb 0.1 mm, Pb 0.1 mm와 Sn 0.36 mm에서 apron의 규격인 납 0.25 mm 두께로 나타났다. 증착시료 Sn+Pb는 Apron의 규격인 0.25 mm 두께보다 차폐효율이 높고, 면적당 무게가 가벼워 방호복 물질로 적합한 적으로 사료된다.

  • PDF

안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가 (Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit)

  • 곽용국;홍순기;하민용;박장필;유숙현;조웅
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2015
  • 목 적 : 안와 주변 방사선 치료 시 수정체 피폭선량감소를 위하여 사용된 2차 차폐 block의 유용성을 알아보고자 한다. 대상 및 방법 : Human phantom(Alderson Rando Phantom, The Phantom Laboratory, USA)을 사용하여 CT(Somatom Definition AS, Siemens, Germany) 모의촬영 후 전산화치료계획시스템(Pinnacle, PHILIPS, USA)을 통해 실제 치료와 유사한 IMRT치료계획을 실시하였다. 2차 차폐를 위하여 두께 3mm 지름 25 mm의 납판과 3 mm tungsten eye-shield block(Extra small size, Radiation Products Design, Inc, USA)를 사용하였으며, TPS(Treatment Planning System) 상의 lens dose와 모의치료 상의 lens dose를 OSLD로 측정 비교하였다. 또한, 5 cm 두께의 acrylic phantom에 동일한 조건의 2차 차폐물인 3 mm 납판과 tungsten eye-shield block을 사용하여 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$)를 조사 및 측정하였으며, 조사야 밖의 누설선 및 투과방사선 영향을 제한시키고자 8 cm 납블럭(O.S.B: Outside Scatter Block)을 적용하여 위와 동일한 실험을 시행하였다. 조사야로부터 1 cm 이격하여 phantom 끝 옆면에 OSLD(Optically Stimulated Luminescence Dosimeter)를 부착하였고, eyelid의 두께에 해당하는 bolus 3 mm를 적용하였다. 결 과 : human phantom을 이용하여 IMRT 치료계획 상의 Lens dose와 실 측정치는 각각 315.9, 216.7 cGy가 측정되었고, 3 mm 납판과 tungsten eye-shield block으로 2차 차폐 후 각각 234.3, 224.1 cGy가 측정되었다. acrylic phantom을 이용한 실험 결과는 no block, 3 mm 납판, tungsten eye-shield block을 사용했을 때 5.24, 5.42, 5.39 cGy가 측정되었으며, 조사야 밖에 O.S.B를 적용하여 no block, 3 mm 납판, tungsten eye-shield block을 실험한 결과 각각 1.79, 2.00, 2.02 cGy가 측정되었다. 결 론 : 광자선 조사 시 critical organ을 보호하기 위하여 2차 차폐를 적용할 시에는 field 외부일지라도 헤드 누설방사선 및 collimator & MLC 투과방사선이 존재하므로 치료부위와 beam 방향에 따라 금속과 같은 높은 원자번호의 차폐물질이 critical organ근처에 있다면 선량 증가의 원인이 될 수 있다는 사실을 알 수 있었다. 따라서 피폭선량 감소를 위한 2차 차폐의 시도는 분명 의미가 있었으나 미 검증된 시도는 오히려 역효과를 가져올 수 있다는 사실을 인지하여 QA를 통해 목적에 부합하는 결과가 나오는지를 사전에 알아보아야 할 것이다.

  • PDF

Feasibility of clay-shielding material for low-energy photons (Gamma/X)

  • Tajudin, S.M.;Sabri, A.H.A.;Abdul Aziz, M.Z.;Olukotun, S.F.;Ojo, B.M.;Fasasi, M.K.
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1633-1637
    • /
    • 2019
  • While considering the photon attenuation coefficient (${\mu}$) and its related parameters for photons shielding, it is necessary to account for its transmitted and reflected photons energy spectra and dose contribution. Monte Carlo simulation was used to study the efficiency of clay ($1.99g\;cm^{-3}$) as a shielding material below 150 keV photon. Am-241 gamma source and an X-ray of 150 kVp were calculated. The calculated value of ${\mu}$ for Am-241 is higher within 5.61% compared to theoretical value for a single-energy photon. The calculated half-value layer (HVL) is 0.9335 cm, which is lower than that of ordinary concrete for X-ray of 150 kVp. A thickness of 2 cm clay was adequate to attenuate 90% and 85% of the incident photons from Am-241 and X-ray of 150 kVp, respectively. The same thickness of 2 cm could shield the gamma source dose rate of Am-241 (1 MBq) down to $0.0528{\mu}Sv/hr$. For X-ray of 150 kVp, photons below 60 keV were significantly decreased with 2 cm clay and a dose rate reduction by ~80%. The contribution of reflected photons and dose from the clay is negligible for both sources.

혼탁매질에서 광분포에 관한 Monte Carlo 시뮬레이션 (Monte Carlo Simulation on Light Distribution in Turbid Material)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.11-20
    • /
    • 1998
  • The propagation of light radiation in a turbid medium is an important problem that confronts dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. Scattered light is measured as a function of the position(distance r, depth z) between the axis of the incident beam and the detection spot. Turbid sample yields a very forward-directed scattering pattern at short range of position from source to detector, whereas the thicker samples greatly attenuated the on-axis intensity at long range of position. The portions of scattered light reflected from or transmitted throughphantom depend upon internal reflectance and absorption properties of the phantom. Monte Carlo simulation method for modelling light transport in tissue is applied. It uses the photon is moved a distance where it may be scattered, absorbed, propagated, internally reflected, or transmitted out of tissue. The photon is repeatedly moved until it either escape from or is absorbed by the phantom. In order to obtain an optimum therapeutic ratio in phantom material, optimum control the light energy fluence rate is essential. This study is to discuss the physical mechanisms determining the actual light dose in phantom. Permitting a qualitative understanding of the measurements. It may also aid in designing the best model for laser medicine and application of medical engineering.

Technical Evaluation of Engineering Model of Ultra-Small Transmitter Mounted on Sweetpotato Hornworm

  • Nakajima, Isao;Muraki, Yoshiya;Mitsuhashi, Kokuryo;Juzoji, Hiroshi;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • 제9권2호
    • /
    • pp.145-154
    • /
    • 2022
  • The authors are making a prototype flexible board of a radio-frequency transmitter for measuring an electromyogram (EMG) of a flying moth and plan to apply for an experimental station license from the Ministry of Internal Affairs and Communications of Japan in the summer of 2022. The goal is to create a continuous low-dose exposure standard that incorporates scientific and physiological functional assessments to replace the current standard based on lethal dose 50. This paper describes the technical evaluation of the hardware. The signal of a bipolar EMG electrode is amplified by an operational amplifier. This potential is added to a voltage-controlled crystal oscillator (27 MHz, bandwidth: 4 kHz), frequency-converted, and transmitted from an antenna about 10 cm long (diameter: 0.03 mm). The power source is a 1.55-V wristwatch battery that has a total weight of about 0.3 g (one dry battery and analog circuit) and an expected operating time of 20 minutes. The output power is -7 dBm and the effective isotropic radiated power is -40 dBm. The signal is received by a dual-whip antenna (2.15 dBi) at a distance of about 100 m from the moth. The link margin of the communication circuit is above 30 dB within 100 m. The concepts of this hardware and the measurement data are presented in this paper. This will be the first biological data transmission from a moth with an official license. In future, this telemetry system will improve the detection of physiological abnormalities of moths.

몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석 (The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation)

  • 정주영;윤도군;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.253-258
    • /
    • 2013
  • 본 연구의 목적은 electronic portal imaging device (EPID)를 통하여 방사선 치료를 받는 환자로부터 투과해 나오는 선량으로 외부적인 선량 재구성과 몬테카를로 전산모사로부터 도출되는 내부 선량 계측과의 관계를 도출하고 이를 분석하기 위한 연구로 진행되었다. 본 연구는 전산모사 연구로써 두 가지의 경우를 비교 분석하고 이와 비슷한 연구에 대한 기본적인 지표를 제공하고자 시행되었다. 실험에 관한 기하학적 정보와 방사선 소스에 대한 정보를 몬테카를로 전산모사 툴인 Monte Carlo n-particle (MCNPX)에 입력하였고 EPID 이미지 도출을 위하여 MCNPX 내에 tally카드를 이용하여 선량정보를 도출하고 이를 영상화 할 수 있도록 하였다. 또한 내부적인 계측을 위하여 물 팬텀을 소스와 표면의 거리(source to surface distance, SSD)가 100 cm이 되도록 설정하였으며, 그보다 10 cm 아래에 EPID를 위치시켰다. 내부 계측은 물팬텀 자체에서 흡수되는 흡수 선량을 mesh tally로 수집하였고, 4문 조사를 통하여 중첩된 선량에 대한 데이터를 획득하였다. 그와 동시에 EPID에서 물을 투과해 나오는 선량을 획득 한 뒤 역 투사 방법을 사용하여 선량 재구성을 하였다. 이둘의 경우를 비교하기 위해 자체적인 교정(calibration)을 통하여 투과해 나온 선량과 흡수된 선량과의 관계를 비교하고 4문 조사를 통하여 물 팬텀 내의 특정 부분에 대한 중첩된 선량 데이터와 EPID를 통해 재구성한 선량 데이터를 분석하였다. 물 팬텀과 EPID에서 획득한 누적 선량의 합은 각각 평균 3.4580 MeV/g과 3.4354 MeV/g이었다. 이는 앞서 계측된 물 팬텀 내부의 누적 선량과 0.6536% 선량 오차를 보였다.

무선통신을 이용한 방사선측정 시스템 개발 (Developement of Radiation Measuring System using Wireless Communication)

  • 이봉재;장시영
    • Journal of Radiation Protection and Research
    • /
    • 제20권2호
    • /
    • pp.85-95
    • /
    • 1995
  • GM 계수관을 방사선 검출기로서 사용하고, 검출기의 신호를 디지탈 펄스로 변환하는 펄스처리회로와 디지탈 통신방식의 하나인 FSK(frequency shift keying) 변복조회로를 설계하였으며, 휴대용 무전기로 송수신되는 방사선 검출신호를 방사선량과 방사선량율로 개인용 컴퓨터의 화면에 표시하는 단일채널 무선 방사선측정 시스템을 개발하고 성능을 평가하였다. 성능검증 실험에서 펄스를 입력한 경우와 검출기에 방사선을 조사시킨 경우 펄스처리회로에서 약 5V의 동일한 디지탈 펄스가 출력되었고, 무선통신계통에서도 입력과 출력이 왜곡없이 송수신되고 있음을 확인하였다. 검출기에 표준방사선원(Cs-137)으로 방사선을 조사시켜 선량률을 측정한 결과 측정오차는 조사된 선량률의 10% 이내를 나타내었다. 본 시스템은 국내에선 처음으로 설계되었으며, 향후 다중채널로 구성하여 실시간 개인방사선피폭선량계, 방사선감시기 등 여러 용도의 방사선측정기에 응용함으로써 방사선방어에 기여할 것으로 기대된다.

  • PDF

Expression of Bacillus thuringiensis CrylAc Protein Fused with Coat Protein of Potato Leafroll Virus

  • Park, Jae-Young;Li, Ming-Shun;Roh, Jong-Yul;Shim, Hee-Jin;Park, Beom-Seok;Je, Yeon-Ho
    • 한국잠사학회:학술대회논문집
    • /
    • 한국잠사학회 2003년도 International Symposium of Silkworm/Insect Biotechnology and Annual Meeting of Korea Society of Sericultural Science
    • /
    • pp.116-117
    • /
    • 2003
  • Aphidicidal activity of Bacillus thurigiensis crystal proteins was recently reported. However, relatively higher dose of crystal protein was needed to kill aphids. In this study, we intended to improve the aphidicidal activity of crystal protein by fusion with coat protein (CP) of potato leafroll virus (PLRV) which is transmitted by aphids. (omitted)

  • PDF