• Title/Summary/Keyword: Transmitted Solar radiation

Search Result 21, Processing Time 0.02 seconds

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

An Effective Algorithm for Transmitted Solar Radiation Calculation through Window Glazing on a Clear Day

  • Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.35-45
    • /
    • 2014
  • The main objective of this study is to provide an effective algorithm of the transmitted solar radiation calculation through window glazing on a clear day. This algorithm would be used in developing a computer program for fenestration system analysis and shading device design. Various simulation methods have been evaluated to figure out the most accurate and effective procedure in estimation of transmitted solar radiation on a tilted surface on a clear day. Characteristics of simulated results of each step have been scrutinized by comparing them with measured results of the site as well as results from other simulation programs. Generally, the Duffie & Beckman's solar calculation method introducing the HDKR anisotropic model provided the most reliable simulation results. The DOE-2 program usually provided over-estimated simulation results. The estimation of extraterrestrial solar radiation and beam normal radiation were conducted pretty accurately. However, the solar radiation either on horizontal surface or on tilted surface involves complicated factors in estimation. Even though the estimation results were close to the real measured data during summer when solar intensity is getting higher, the estimation provided more error when solar intensities were getting weaker. The convex polygon clipping algorithm with homogeneous coordinates was fastest model in calculation of sunlight to shaded area ratio. It could not be applied because of its shape limitation.

Analysis of Direct and Diffuse Radiation in Plastic Greenhouse (플라스틱 하우스의 직달(直達) 및 산란(散亂) 일사량(日射量) 해석(解析))

  • Koh, Hak-Kyun;Kim, Moon-Ki;Kim, Yong-Hyeon
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.13-24
    • /
    • 1989
  • Direct and diffuse components of solar radiation were measured inside and outside a single-span plastic greenhouse. To analyze the direct solar radiation inside the plastic greenhouse, the cross-section of the greenhouse was assumed to be circular. Then the direct solar radiation transmitted into the greenhouse was calculated theoretically, and compared with the experimental measurements. The results are summarized as follows: (1) The transmissivities of total solar radiation were about 65% on cloudy days and 50% on clear days. For cloudy days, the transmissivity of the total solar radiation was regarded as the transmissivity of sky diffuse radiation. (2) The ratio of the inside effective scattered component of direct solar radiation to the diffuse radiation was 60-65%. (3) It appeared that the seasonal variation of the transmissivity of total solar radiation was adversely affected by the transmissivity of direct solar radiation and the effective scattered coefficient. But the effect of the transmissivity of direct solar radiation was dominant factor. (4) Computer simulation showed that the inside direct solar radiation was decreased as the floor of the plastic greenhouse was higher. (5) The predicted value of the inside direct solar radiation was 3.3% to 29.0% higher than the measured value.

  • PDF

Characteristics of Shortwave Radiation Absorption by Soybean Canopy I. Absorption of Total Shortwave Radiation and Its Relation to Dry Matter Production (콩군락의 단파폭사 흡수특성I. 전두파폭사수지와 건물생산)

  • 이양수;윤성호;임정남
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.2
    • /
    • pp.151-155
    • /
    • 1990
  • A field experiment was conducted to study both the distribution characteristics of shortwave radiation in the soybean canopy and its relationship with dry matter production. The soybean 'Paldalkong' was sown with the space of 45${\times}$10cm at Suwon on May 27. 1988. The extinction coefficient of solar radiation remained constant (0.53) after full canopy was reached. The 31.9% of the incoming solar radiation was transmitted. The reflected radiation from the plant canopy increased lineary with incoming solar radiation (R$^2$=0.9346). As leaf area index become larger than 2.5. the reflected radiation showed more significant linear relationship with the differences in the radiations between incoming and transmitted radiation than incoming solar radiation (R$^2$=0.9558). The mean reflectance during the growing period was 24.7%. A significant linear relationship (R$^2$=0.9930) had been admitted between the accumulated solar radiation intercepted by the canopy and dry matter production of 'Paldalkong' until the 35th day of ripening stage. The conversion efficiency of solar radiation intercepted to dry matter of soybean was 1.45g MJ$\^$-1/.

  • PDF

Distribution and Variation Characteristic of Solar Radiation Resources in Korea (국내 태양복사 분포 및 변화특성)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.1-200.1
    • /
    • 2010
  • Solar energy is one of the most promising energy resources in the future. For the application and dissemination of solar energy technologies in various fields, reliable data sets of solar irradiation are needed for engineers, researchers, businessmen, and policy makers. Global horizontal solar radiation is needed for the use of flat plate collector, solar domestic hot water system, photovoltaic devices and passive systems like green house. In many countries, solar radiation data accumulated for more then 40 or 50 years and typical weather data are published with average of more then 30 years. In Korea, those global total radiations are measured for about 30 years. With the connections of computer network, measured data could be transmitted to the central control system at key station through Ethernet lines. The data acquisition systems are connected to be automatically controlled by the monitoring network. Global horizontal solar radiation data 16 locations were measured and averaged from 1982 to 2008.

  • PDF

THE EFFECT OF ATMOSPHERIC SCATTERING AS INFERRED FROM THE ROCKET-BORNE UV RADIOMETER MEASUREMENTS

  • Kim, Jhoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.87-93
    • /
    • 1997
  • Radiometers in UV and visible wavelengths were onboard the Korean Sounding Rocket(KSR)-1 and 2 which were launched on June 4th and September 1st, 1993. These radiometers were designed to capture the solar radiation during the ascending period of the rocket flight. The purpose of the instrument was to measure the vertical profiles of stratospheric ozone densities. Since the instrument measured the solar radiation from the ground to its apogee, it is possible to investigate the altitude variation of the measured intensity and to estimate the effect of atmospheric scattering by comparing the UV and visible intensity. The visible channel was a reference because the 450-nm wavelength is in the atmospheric window region, where the solar radiation is transmitted through the atmosphere without being absorbed by other atmospheric gases. The use of 450-nm channel intensity as a reference should be limited to the altitude ranges above the certain altitudes, say 20 to 25km where the signals are not perturbed by atmospheric scattering effects.

  • PDF

Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System (공기순환구조를 갖는 축열지붕의 열전달해석)

  • Shin, U.C.;Park, S.H.;Baek, N.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance (재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, U-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

A Design of Thermosiphoning Air Panel and its Performance Analyzing (자연 대류식 태양열 집열기 (TAP)의 설계와 평가)

  • Shin, H.Y.;Lee, K.H.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.51-57
    • /
    • 1984
  • The aim of the study is to the thermal performance of TAP (Thermosiphoning Air Panel) which is easily applicable to existing building as well as new building. TAP is one of the advantageous means of passive solar system, with a view to reducing the energy consumption of existing and new building. The instantaneous thermal efficency of a thermo siphoning collector depends primarily on the heat loss coefficient of the collector, the effectiveness of heattransfer between the absorber and the air, the average air temperature in the collector, the ambient air temperature, and the transmitted solar radiation. Because the important design variables are interrelated, it is, difficult to determine the effect of design decisions based on intuition. Therefore economical and effective TAP can be used easily, TAP had been designed and analyzed.

  • PDF

An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer (이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구)

  • Kim, Dong-Kyun;Yoon, Kap-Chun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.