• Title/Summary/Keyword: Transmission-ratio

Search Result 1,790, Processing Time 0.032 seconds

Seismic response control of transmission tower-line system using SMA-based TMD

  • Tian, Li;Zhou, Mengyao;Qiu, Canxing;Pan, Haiyang;Rong, Kunjie
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.129-143
    • /
    • 2020
  • This study proposes a new shape memory alloy-tuned mass damper (SMA-TMD) and investigates the effectiveness of this damper in reducing and controlling the vibrations of a transmission tower-line system under various seismic excitations. Based on a practical transmission line system and considering the geometric nonlinearity of this system, the finite element (FE) software ANSYS is used to create an FE model of the transmission tower-line system and simulate the proposed SMA-TMD. Additionally, the parameters of the SMA springs are optimized. The effectiveness of a conventional TMD and the proposed SMA-TMD in reducing and controlling the vibrations of the transmission tower-line system under seismic excitations is investigated. Moreover, the effects of the ground motion intensity and frequency ratio on the reduction ratio (η) of the SMA-TMD are studied. The vibration reduction effect of the SMA-TMD under various seismic excitations is superior to that of the conventional TMD. Changes in the ground motion intensity and frequency ratio have a significant impact on the η of the SMA-TMD. As the ground motion intensity and frequency ratio increase, the η values of the SMA-TMD first increase and then decrease. Studying the vibration reduction effects of the SMA-TMD can provide a reference for the practical engineering application of this damper.

A study on effects of water-cement ratio and crack width on chloride ion transmission rate in concrete

  • Li, Yue;Chen, Xiaohan;Zhang, Guosheng
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.387-394
    • /
    • 2017
  • To study the effects of water-cement ratio changes and cracks on chloride ion transmission rate in cracked concrete, RCM method was adopted to accelerate the diffusion of chloride ion in cracked concrete, and the changes in chloride ion concentration and around the cracks are inferred by finite-element method. The test results show that as far as prefabricated cracks on concrete components are concerned, the width thresholds of two cracks on the concrete specimens with a water-cement ratio of 0.5 and 0.6 are 0.05 mm and 0.1 mm respectively, the width threshold of two cracks on the concrete specimens with a water-cement ratio of 0.4 is 0.05 mm and 0.2 mm respectively; and the results of numerical simulation show that the smaller the water-cement ratio is, the more significant effects of cracks on chloride ion transmission rate are. As a result, more attention shall be paid to the crack prevention, repairing and strengthening for high-strength concrete.

Photosynthetic, Morphological and Growing Characteristics by Shading Materials in Panax ginseng C. A. Meyer (차광재 종류가 묘삼의 광합성, 형태 및 생육에 미치는 영향)

  • Cho, Jin-Woong;Park, Hong-Woo;Kim, Min-Jung;Kim, Hyun-Ho;Choi, Jae-Eul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.3
    • /
    • pp.256-260
    • /
    • 2008
  • This study was conducted to response the photosynthetic rate and anatomical characters in one year ginseng plant against the light transmission ratio (10%, 20% and 30% in natural light) under shading materials by polyethylene (PE) net. The chlorophyll content and the photosynthesis of ginseng according to the light transmissivity showed decreasing trend as the light transmission ratio increased. At the higher light transmission ratio condition, leaves showed the chlorosis due to the physiological disorder, stems formed hypodermis, and phloem development inside the vascular tissue shrunk remarkably. Also, roots showed the epidermis destruction and less cambium development at the higher light intensity. The root weight also decreased as the light transmission ratio increased.

An Experimental Study on the Estimate of Wind Force Coefficient of Transmission Tower Rectangular Frame (철탑 사각골조의 풍력 계수 산정에 관한 실험적 연구)

  • Shin, Koo-Yong;Lim, Jae-Seob;Hwang, Kyu-Seok;Kil, Yong-Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.73-81
    • /
    • 2011
  • The wind force coefficient of a transmission tower frame shows several characteristics when the section shape, solidity ratio, and wind direction angle are changed. In this study, the wind force characteristics of a transmission tower frame with a basic structure were evaluated using different solidity ratios and wind direction angles in a wind tunnel test. According to the solidity ratio, the size of the structure and the rectangular-frame model of the transmission tower were changed by adding a two-dimensional (2D) or three-dimensional (3D) structure. The transmission tower's rectangular frame was tested by changing the wind direction angle of the 2D-type structure from 0 to $90^{\circ}$ and by changing the wind direction angle of the 3D-type structure from 0 to $45^{\circ}$ Based on the results that were obtained, it can be concluded that the wind force coefficient of a transmission tower frame can be used as preliminary data in deciding the transmission tower's wind load.

A Simulation Analysis for Selecting In/Out Port Ratio in FAX Network System Operation (팩스 통신망 입출력회선 비율 설정에 관한 시뮬레이션 분석)

  • 나윤균
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.2
    • /
    • pp.101-109
    • /
    • 1999
  • In a commercial facsimile network system, a simulation analysis has been performed using ARENA due to the unavailability of theoretical models. The effect of a priority is compared with that of the current FCFS rule on the arriving call blocking rate and transmission time delay. The result shows that the priority rule reduces more service time delay as the arrival rate increases. A simulation analysis procedure is proposed to select optimal in/out port ratio at various hourly arrival rates with a given multiple-place transmission requests ratio.

  • PDF

A Study on Utilization Ratio and Operation of Transmission Lines (송전선로의 이용률 평가 및 합리적 운영에 관한 연구)

  • Kim, Dong-Min;Bae, In-Su;Cho, Jong-Man;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

A study on Shift Efficiency Characteristics of a 2-speed Transmission applying CVT Structure (CVT구조를 적용한 2단 변속기의 효율특성에 관한 연구)

  • Kwang-Wook Youm
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.59-64
    • /
    • 2024
  • In this study, we conducted research on a miniaturized transmission system suitable for ultra-compact electric vehicles, such as electric arts or small electric cars. While conventional electric vehicles eliminate multi-gear transmissions and control motor output or secure initial driving force through reducers, in vehicles like electric karts or compact electric cars, which have relatively small battery capacities, the driving range can be reduced or the motor can be stressed epending on the loading state. Therefore, in this study, we developed a low stage ratio 0.625 and high stage ratio 1.6 a two-stage transmission system that can change gears as needed, considering factors such as slope conditions and loading status, by applying the continuously variable transmission (CVT) mechanism. Based on the selected gear ratios, we designed the transmission and created a test rig to verify the power transmission efficiency of the developed transmission. Using the test rig, we varied the rotational speed and load of the transmission to confirm its power transmission characteristics and also examined the heat generation characteristics during shifting and operation. As a result, developed a two-stage transmission with a CVT structure.

Effects of the external optical feedback on the DFB-LD modules for 2.5Gbps optical communication system (2.5Gbps 광통신용 DFB-LD 모듈에 대한 광궤환의 영향)

  • 박경현;이중기;한정희;조호성;장동훈;박철순
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.1-14
    • /
    • 1996
  • Effects of the external optical feedback on the optical transmission characteristics were evaluated for 3 kinds of commercialized DFB-LD modules for 2.5Gbps optical communication systems. As a result, intensity noise induced by external optical feedback via generating the external cavity modes deteriorated the transmission performances of sthe DFB-LD modules as much as 1.5dB, 1.2dB, and 1.0dB for the maximum feedback ratio of -8.8dB which corresponds to the worst reflection along the fiber transmission line. Additional penalty of 0.5dB was occurrred when state of polarization of feedback light was adjusted. From the experiments evaluating the isolation ratio of the single polarization optical isolator, decrease of the polarization dependent isolation ratio as much as 10dB from that of specification and the effective isolation ratio as much as 20dB from that of specification was mjor cause of high sensitivity of DFB-LD modules to external feedback. It was suggested that polarization independent optical isolator or single polarization optical isolator with isolation ratio specification of more than 40dB is required for 2.5Gbps DFB-LD modules with complete suppression of external feedback effects.

  • PDF

Micro-morphological Features of Liquid Urea-Formaldehyde Resins during Curing Process at Different Levels of Hardener and Curing Time Assessed by Transmission Electron Microscopy

  • Nuryawan, Arif;Park, Byung-Dae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.125-130
    • /
    • 2014
  • This study used transmission electron microscopy (TEM) to investigate the micro-morphological features of two formaldehyde to urea (F/U) mole ratio liquid urea-formaldehyde (UF) resins with three hardener levels as a function of the curing time. The micro-morphological features of the liquid UF resins were characterized after different curing times. As a result, the TEM examination revealed the presence of globular/nodular structures in both liquid UF resins, while spherical particles were only visible in the low F/U mole ratio resins. The high F/U mole ratio liquid UF resins also showed extensive particle coalescence after adding the hardener, along with the appearance of complex filamentous networks. When the resins were cured with a higher amount of hardener and longer curing time, the spherical particles disappeared. For the low mole UF resins, the particles tended to coalesce with a higher amount of hardener and longer curing time, although discrete spherical particles were still observed in some regions. This is the first report on the distinct features of the crystal structures in low F/U mole ratio UF resins cured with 5% hardener and after 0.5 h of curing time. In conclusion, the present results indicate that the crystal structures of low F/U mole ratio UF resins are formed during the curing process.

A Study on the Performance of Continuously Variable Transmission composed of V-belt Drive and 2K-H type Differential Gear Unit (2K-H형 차동기어장치와 V-belt를 결합한 무단변속기의 성능에 관한 연구)

  • 박재민;김연수;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.739-742
    • /
    • 1997
  • Continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdriver mode. They are not required of a starting device as a torque converter. CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and theoretical efficiency are executed.

  • PDF