• 제목/요약/키워드: Transmission-Loss

검색결과 2,307건 처리시간 0.031초

CFD를 이용한 단순확장관의 음향특성 해석 (Acoustical Performance Analysis of the Simple Expansion Chamber by using CFD)

  • 김대환;정철웅;정의봉;김형태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1354-1359
    • /
    • 2007
  • This paper discusses the acoustic performance of simple expansion chamber using computational fluid dynamics(CFD). The CFD model consists of an axisymmetric grid with a single period sinusoid of acceptable amplitude and duration imposed at the inlet boundary condition. The time history of the static pressure is recorded at two points, one in the inlet pipe and one point in outlet pipe. The time history of the static pressure is converted to the frequency domain using Fourier Transform and the transmission loss (TL) of the muffler is obtained from the ratio of the static pressure at the inlet and outlet pipe. The transmission loss of CFD result is compared with that of the computational acoustic analysis using the boundary element method (BEM). There are some differences in two results due to the pressure drop according to the inlet and outlet pipe length. Therefore, the effects of the pressure drop to the transmission loss have to be considered.

  • PDF

Coordinated Wide-Area Regulation of Transmission System for Voltage Profile Improvement and Power Loss Reduction

  • Asadzadeh, Babak;Golshannavaz, Sajjad
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.279-286
    • /
    • 2017
  • In this paper, an optimal approach for the wide-area regulation of control devices in a transmission network is proposed. In order to realize an improved voltage profile and reduced power loss, existing devices such as tap-changing transformers, synchronous machines, and capacitor banks should be controlled in a coordinated and on-line manner. It is well-understood that phasor measurement units in transmission substations allow the system operators to access the on-line loading and operation status of the network. Accordingly, this study proposes efficient software applications that can be employed in area operation centers. Thus, the implanted control devices can be regulated in an on-line and wide-area coordinated approach. In this process, efficient objective functions are devised for both voltage profile improvement and power loss reduction. Subsequently, sensitivity analysis is carried out to determine the best weighting factors for these objectives. Extensive numerical studies are conducted on an IEEE 14-bus test system and a real-world system named the Azarbayjan Regional Transmission Network. The obtained results are discussed in detail to highlight the promising improvements.

다공관 소음기의 투과손실에 관한 실험적 연구 (An Experimental Study on the Transmission Loss of Perforated Tube Mufflers)

  • 김찬묵;사종성;방극호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.346-352
    • /
    • 2002
  • This paper is the experimental study to estimate the influence of various design parameters on the performance of mufflers with perforated tubes and through-flow partitions. Muffler types considered in the present work include through-flow chamber, through-flow chamber with partition, and cross-flow chamber. The influences of the design parameters on the performance of the mufflers can be outlined as follows. In the case of the through-f]ow type mufflers, increasing the tube thickness and the hole diameter of the perforated tubes does not change the maximum value of the transmission loss but decrease the cutoff frequency. In the case of the through-flow with partitions type mufflers, it is shown that combining a fe w short chambers and long chambers can modify the frequency locations of the resonance frequencies to optimize the performance of the mufflers. For the case of the cross-flow type mufflers, it is shown that the transmission loss of the mufflers is mainly affected by the lower porosity when the porosities are different in both sides of the plug. Overall, it is shown that performance of the through-flow type with partition type mufflers is excellent in the lower frequency region, where the cross-flow type mufflers have better performance in the higher frequency region.

  • PDF

연속적인 패킷 손실 제어와 제로 윈도우 제어를 이용한 무선 TCP 전송 성능 향상 연구 (A Study of efficient Wireless TCP Transmission Using Consecutive Packet Loss and Zero Window Control)

  • 김성찬;전문석
    • 정보처리학회논문지A
    • /
    • 제13A권7호
    • /
    • pp.573-580
    • /
    • 2006
  • 기존의 가장 널리 쓰이는 전송계층 프로토콜인 TCP는 패킷 손실의 원인이 망의 혼잡 때문이라는 가정 하에 설계된 프로토콜로서 유선망과 고정 호스트로 이루어진 전통적인 네트워크에는 적합하지만 페이딩, 잡음, 간섭 등의 전송 에러가 발생하는 무선 환경에서는 전송 프로토콜로서 적용하기에 비효율적이다. 이것은 무선망에서의 비트 에러에 의한 패킷손실 역시 혼잡으로 간주하여 불필요한 전송 제어가 발생하기 때문이다. 본 논문에서는 무선 TCP 패킷의 전송성능을 향상시키기 위하여 연속적인 패킷 손실에 대한 제어와 TCP 윈도우 제어를 하여 불필요한 혼잡제어 알고리즘을 수행하지 않게 하는 개선된 SNOOP 프로토콜을 제안하였고 개선된 모듈의 성능을 모의실험을 통하여 확인하였다.

배기계 디커플러의 음향 특성에 관한 연구 (A Study on the Acoustical Characteristics of Exhaust Decoupler)

  • 허덕재;임종윤
    • 한국자동차공학회논문집
    • /
    • 제14권5호
    • /
    • pp.93-99
    • /
    • 2006
  • Flexible couplers are widely used for exhaust transmitted vibration reduction in vehicles. This paper describes an investigation into the acoustical characteristics of exhaust flexible coupler by the simulation and testing. Computational acoustic simulation is carrying out to investigate resonance frequency and transmission loss of decoupler using the boundary element method and transfer matrix approach. To confirm the acoustical simulation results of exhaust decoupler, we compare with measured experimental results by the test of transmission loss measurement system. In the comparison with simulation results and tests results, there is correctly fit the resonance frequency and the trend of transmission loss. Also, we show that the acoustical structure of decoupler is analogous to the expended tube or side branch resonator. The characteristics of exhaust decoupler have a marked increase in the acoustic attenuation at the specified frequency bend. Therefore the decoupler is applied to develop the exhaust system not only for the vibration isolator but also for the noise attenuator.

Sound Absorption Rate and Sound Transmission Loss of CLT Wall Panels Composed of Larch Square Timber Core and Plywood Cross Band

  • Kang, Chun Won;Jang, Sang Sik;Kang, Ho Yang;Li, Chengyuan
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권1호
    • /
    • pp.33-39
    • /
    • 2019
  • The square timbers of larch having cross section of $90mm{\times}90mm$ were glued laterally to be formed $1,200mm{\times}2,400mm$ panels which were used as cores for CLT wall panels. Then, structural plywood panels having size of $1,200mm{\times}2,400mm$ were used as cross band covering the small square timber cores to manufacture CLT wall panels. The sound absorption rate of CLT wall panels and polyester board attached CLT wall panels were investigated. The mean sound absorption coefficients of the former and the latter in the frequency range of 100-6400 Hz were 0.21 and 0.74, respectively. The noise reduction coefficients (NRC) of those were 0.21 and 0.40, respectively. Also, the mean sound transmission loss of CLT wood panel in the frequency range of 50-1600 Hz was 45.12 dB and that value at the frequency of 500 Hz was 42.49 dB. It was suggested that the polyester board attached CLT wall panels could be used as housing wall because of its high sound absorption rate and high sound transmission loss.

발전 에너지원별 송전손실 변동특성 분석 (Analysis of Transmission Loss Characteristics on Generation Energy Resources)

  • 남궁재용;문영환;오태규;임성황
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.248-250
    • /
    • 2001
  • In this paper, marginal loss factors are calculated for 12 load cases that represent the impact of marginal network tosses on nodal prices at the transmission network connection points at which generators are located. Based on comparison analysis of marginal loss factors on generation energy resources, we can find the characteristics of each plants according to its energy resources in KOREA.

  • PDF

송전손실에 의한 전력시스템의 상태식별법 (System State Identification using Transmission Loss)

  • 이형수;심건보;이봉용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.196-200
    • /
    • 1992
  • Transmission loss retains a complete set of system state information. If we could exploit its behavior, we could find various useful applications. This study is a such exploitation to find same possibilities of the loss application. It seems to have very prospective possibilities. It has been tried to establish some network indices to indicate operation margin. And further some prospective applications are suggested.

  • PDF

나전선(裸電線)의 저손실화 설계 (Design of the Bare Electric Wire for Low Loss)

  • 정연호;이형권;손홍관;조연규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.101-103
    • /
    • 1998
  • New transmission lines are gradually constructed with high voltage and power for increase of electric power demands. And electric losses that are produced in line are increased. we made the algorithm for low loss wire and developed the computer program that makes loss of electric wire to be decreased for efficient power transmission. Electric wire is designed not to be decreased electrical and mechanical properties than that of existing electric wire.

  • PDF

System Identification of Internet transmission rate control factors

  • Yoo, Sung-Goo;Kim, Young-Seok;Chong, Kil-To
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.652-657
    • /
    • 2004
  • As the real-time multimedia applications through Internet increase, the bandwidth available to TCP connections is oppressed by the UDP traffic, result in the performance of overall system is extremely deteriorated. Therefore, developing a new transmission protocol is necessary. The TCP-friendly algorithm is an example meeting this necessity. The TCP-friendly (TFRC) is an UDP-based protocol that controls the transmission rate based on the available round transmission time (RTT) and the packet loss rate (PLR). In the data transmission processing, transmission rate is determined based on the conditions of the previous transmission period. If the one-step ahead predicted values of the control factors are available, the performance will be improved significantly. This paper proposes a prediction model of transmission rate control factors that will be used for the transmission rate control, which improves the performance of the networks. The model developed through this research is predicting one-step ahead variables of RTT and PLR. A multiplayer perceptron neural network is used as the prediction model and Levenberg-Marquardt algorithm is used for the training. The values of RTT and PLR were collected using TFRC protocol in the real system. The obtained prediction model is validated using new data set and the results show that the obtained model predicts the factors accurately.

  • PDF