• Title/Summary/Keyword: Transmission costs

Search Result 239, Processing Time 0.027 seconds

Verification of ERP Standard Time Using TOC Technique and Improvement of MES Routing Point (TOC 기법을 적용한 ERP 표준시간 검증 및 MES 공정실적개선)

  • Kim, Sung-Min;Ahn, Jaekyoung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.22-33
    • /
    • 2018
  • Recently domestic manufacturing companies have been experiencing worsening profitability and stunted growth due to the long-term economic recession and the rapid rise of developing countries such as China and Southeast Asia. These difficulties force many companies to concentrate their core competencies on new value creation and innovation in order to gain momentum for new growth. Enterprise Resource Planning (ERP) has been considered as one of viable solutions. Among the various modules in ERP, shop floor control function in the production management module is rather limited. In order to overcome this problem, Manufacturing Execution System (MES) has been used as a subsystem which has a strong information gathering power and flexibility. Both systems interact closely with each other. In particular, ERP requires fast, accurate shop floor information at MES. This paper describes how to synchronize relevant information between ERP and MES with theory of constraints (TOC). The processing time information transmitted from the MES workplace is received at the ERP workplace. In the process, the received processing time is causing information distortion in ERP, when the information gathering standard of MES is different from the ERP information interpretation standard. The Drum-Buffer-Rope theory of TOC was applied to resolve this problem, therefore, information synchronization between both systems was made. As a precondition, the standard time of the upper ERP system was rearranged according to the capacity constraints resource. As a result, standard time restructuring has affected changes in labor costs. Standard labor costs have come close to actual ones, and information synchronization of MES transmission data has improved the reliability of standard product costs, such that it enabled various company-wide restructuring actions to be much more effective.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

A Study on ADSL transmission speed enhancement in High-speed Internet (초고속 인터넷을 위한 ADSL 전송속도 향상연구)

  • 김홍모;고남영
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1077-1083
    • /
    • 2000
  • With rising demand of Internet Service, the existing communication for users (aced the restricted capability and speed, and also failed to satisfy consumer's desire for providing service-quality to them. It can be accomplished the broad-band on subscribe-line to offer various multimedia service to subscriber. But it takes a lot of times and costs. Consequently, it stands out the most economic subscribe-line for acheving a broadband scheme that new transmission technology can be realized the high-speed data communication as the present telephone-line and telephone by the general public of FTTH(Fiber To The Home). As using the pseudo line, this paper have the result that the mesured speed was improved by connecting a variable resistor on the line.

  • PDF

Compressing Method of NetCDF Files Based on Sparse Matrix (희소행렬 기반 NetCDF 파일의 압축 방법)

  • Choi, Gyuyeun;Heo, Daeyoung;Hwang, Suntae
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.11
    • /
    • pp.610-614
    • /
    • 2014
  • Like many types of scientific data, results from simulations of volcanic ash diffusion are of a clustered sparse matrix in the netCDF format. Since these data sets are large in size, they generate high storage and transmission costs. In this paper, we suggest a new method that reduces the size of the data of volcanic ash diffusion simulations by converting the multi-dimensional index to a single dimension and keeping only the starting point and length of the consecutive zeros. This method presents performance that is almost as good as that of ZIP format compression, but does not destroy the netCDF structure. The suggested method is expected to allow for storage space to be efficiently used by reducing both the data size and the network transmission time.

Optimal Operation by integrating Sihwa Power into NamSihwa Systems (시화조력발전 연계에 의한 남시화 계통의 최적 운영 방안)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.120-126
    • /
    • 2009
  • This paper presents an optimal operating scheme by integrating Sihwa tidal power into NamSihwa systems. For optimal operation of NamSihwa systems, the sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water are calculated. Especially, it is compared by three schemes to purchase total power from transmission system to purchase total power from tidal power system in time period that can generate tidal power and to purchase total power by comparing purchase costs from transmission system and tidal power system. The scheme may contribute to energy save in Korea that natural resources are lacking.

A Development of Demand Response Operation System and Real-Time Pricing based on Smart Grid (스마트그리드 기반의 실시간요금제 및 DR운영시스템 구현)

  • Ko, Jong-Min;Song, Jae-Ju;Kim, Young-Il;Jung, Nam-Jun;Kim, Sang-Keu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1964-1970
    • /
    • 2010
  • A new intelligent power network (Smart Grid) that grafts some new technologies, such as the extension of the new and reproducible energy, electric motors, and electric storages, onto the regulation of green house gases according to the recent convention on climate changes has been actively promoted. As establishing such an intelligent power network, it is possible to implement a real-time rate system according to the change from the conventional single directional information transmission to the bidirectional information transmission. Such a real-time rate system can provide power during the chip rate hour by avoiding the high rate hour although customers use the same level of power through providing such real-time rate information including power generation costs. In this study, the establishment of an operating system that makes an effective use of the real-time rate system and its operation method are to be proposed.

Transmission Network Expansion Planning for the Penetration of Renewable Energy Sources - Determining an Optimal Installed Capacity of Renewable Energy Sources

  • Kim, Sung-Yul;Shin, Je-Seok;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1163-1170
    • /
    • 2014
  • Due to global environmental regulations and policies with rapid advancement of renewable energy technologies, the development type of renewable energy sources (RES) in power systems is expanding from small-scale distributed generation to large-scale grid-connected systems. In the near future, it is expected that RES achieves grid parity which means the equilibrium point where the power cost of RES is equal to the power costs of conventional generators. However, although RES would achieve the grid parity, the cost related with development of large-scale RES is still a big burden. Furthermore, it is hard to determine a suitable capacity of RES because of their output characteristics affected by locations and weather effects. Therefore, to determine an optimal capacity for RES becomes an important decision-making problem. This study proposes a method for determining an optimal installed capacity of RES from the business viewpoint of an independent power plant (IPP). In order to verify the proposed method, we have performed case studies on real power system in Incheon and Shiheung areas, South Korea.

Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer (345kV 승압용 변전소의 뇌격에 의한 이상전압 해석)

  • Cho, Man-Young;Shin, Ho-Jeon;Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

Secure Data Transmission Scheme between Network for Building Facilities Control System (빌딩시설 제어시스템용 안전한 망간 자료전송 방안)

  • Jo, In-June
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.102-108
    • /
    • 2018
  • The existing data transmission technology applied between the non-secure external internet and the secure internal business network has various problems when applied to the building facility management SCADA system control network. Traditional inter-network data transfer technologies involve high complexity and high costs because blacklist-based security techniques are applied to all data. However, whitelist-based security techniques can be applied to data distributed in Building Facility Management SCADA control systems because a small number of structured control data are repeatable and periodic. This simplifies the security technology applied to inter-network data transmission, enabling building facility management SCADA system control network deployment at low cost. In this paper, we proposed building control networks specialized in building facility management SCADA control systems by providing solutions to address and address these problems.