• Title/Summary/Keyword: Transmission Oil

Search Result 240, Processing Time 0.027 seconds

The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

Development of A/T Oil Temperature Sensor Plausibility Diagnostic Logic (자동변속기 오일 온도센서 출력 이상 진단 로직 개발)

  • Kwon, Jun-Eui;Choi, Young-Sun;Sim, Jang-Sun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.99-104
    • /
    • 2005
  • The CARB in USA has demanded OBD functions that detect any deterioration of performance of OTS as well as a simple defect of OTS which can affect emission to meet the reinforced emission regulation. In this paper, OTS plausibility monitoring functions to meet the demand from CARB are discussed. The output from OTS is used for the diagnostics of the torque converter clutch stuck and the gear ratio synchronous error. It is possible to diagnose the abnormality of OTS function by considering the oil temperature characteristics which changes according to the driving status of vehicles. In result, the OBD regulations of the CARB can be satisfied obligating car manufacturer to detect any problems in OTS functions which can affect emissions.

Effects of Garlic Oil on Pancreatic Cancer Cells

  • Lan, X.Y.;Sun, H.Y.;Liu, J.J.;Lin, Y.;Zhu, Z.Y.;Han, X.;Sun, X.;Li, X.R.;Zhang, H.C.;Tang, Z.Y.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5905-5910
    • /
    • 2013
  • Background: To investigate the preventive and therapeutic potential of garlic oil on human pancreatic carcinoma cells. Methods: The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) assay was performed to study the effects of garlic oil on three human pancreatic cancer cell lines, AsPC-1, Mia PaCa-2 and PANC-1. Cell cycle progression and apoptosis were detected by flow cytometry (FCM), staining with PI and annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI), respectively. Morphologic changes of pancreatic cancer cells were observed under transmission electron microscopy (TEM) after treatment with garlic oil at low inhibitory concentrations ($2.5{\mu}M$ and $10{\mu}M$) for 24 hours. Results: Proliferation of the AsPC-1, PANC-1, and Mia PaCa-2 cells was obviously inhibited in the first 24 hours with the MTT assay. The inhibition effect was more significant after 48 hours. When cells were exposed to garlic oil at higher concentrations, an early change of the apoptotic tendency was detected by FCM and TEM. Conclusion: Garlic oil could inhibit the proliferation of AsPC-1, PANC-1, and Mia PaCa-2 cells in this study. Moreover, due to programmed cell death, cell cycle arrest, or both, pro-apoptosis effects on AsPC-1 cells were induced by garlic oil in a dose and time dependent manner in vitro.

Rancidity Prediction of Soybean Oil by Using Near-Infrared Spectroscopy Techniques

  • Hong, Suk-Ju;Lee, Ah-Yeong;Han, Yun-hyeok;Park, Jongmin;So, Jung Duck;Kim, Ghiseok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.3
    • /
    • pp.219-228
    • /
    • 2018
  • Purpose: This study evaluated the feasibility of a near-infrared spectroscopy technique for the rancidity prediction of soybean oil. Methods: A near-infrared spectroscopy technique was used to evaluate the rancidity of soybean oils which were artificially deteriorated. A soybean oil sample was collected, and the acid values were measured using titrimetric analysis. In addition, the transmission spectra of the samples were obtained for whole test periods. The prediction model for the acid value was constructed by using a partial least-squares regression (PLSR) technique and the appropriate spectrum preprocessing methods. Furthermore, optimal wavelength selection methods such as variable importance in projection (VIP) and bootstrap of beta coefficients were applied to select the most appropriate variables from the preprocessed spectra. Results: There were significantly different increases in the acid values from the sixth days onwards during the 14-day test period. In addition, it was observed that the NIR spectra that exhibited intense absorption at 1,195 nm and 1,410 nm could indicate the degradation of soybean oil. The PLSR model developed using the Savitzky-Golay $2^{nd}$ order derivative method for preprocessing exhibited the highest performance in predicting the acid value of soybean oil samples. onclusions: The study helped establish the feasibility of predicting the rancidity of the soybean oil (using its acid value) by means of a NIR spectroscopy together with optimal variable selection methods successfully. The experimental results suggested that the wavelengths of 1,150 nm and 1,450 nm, which were highly correlated with the largest absorption by the second and first overtone of the C-H, O-H stretch vibrational transition, were caused by the deterioration of soybean oil.

A Study on the Phase Bandwidth Frequency of a Directional Control Valve based on the Metering Orifice (미터링 오리피스를 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구)

  • Kim, Sungdong;Jeon, Sehyeong;Yun, Jooseop
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • The spool displacement of directional control valve can be considered as the standard signal to measure the bandwidth frequency of a directional control valve. When the spool displacement is not available, the metering-orifice system is implemented in this research as an alternative way of measuring the 90 degrees phase bandwidth frequency of the hydraulic directional control valve. The inertia effect on the transmission line oil induces the phase lead of the valve load pressure when compared with the phase of spool displacement. The capacitance effect of the oil induces the phase lag of the valve load pressure. The phase of the load pressure can be adjusted to be the same as that of the spool displacement by controlling the opening area of the metering orifice. A series of experiments were conducted to verify the effectiveness of the metering orifice. The 90 degrees phase bandwidth frequency measured from the valve load pressure was significantly deviated in some cases from the frequency of the spool displacement. The metering orifice was hard to be applied to measure the -90 degrees phase bandwidth frequency of the high precision.

DEVELOPMENT OF 275kV OIL FILLED CABLE & ITS ACCESSORIES (275kV O.F 케이블로 부속재 인증시험 완료)

  • Kwon, B.I.;Nam, J.S.;Oh, E.J.;Kim, H.J.;Choi, B.N.;Lee, S.R.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2057-2059
    • /
    • 2000
  • The underground transmission system has been internationally developing the voltage class of which increase to realizing high reliability and efficiency. Under this situation, if a company don't do much labor to elevating one's technology, the company will be hard to compete against other companies in trade. Our company has successfully developed 275kV oil-filled cable and its accessory in 1999 for Malaysia project, which was based on accumulated technological know-how, which is the highest voltage level among awarded oversea underground transmission networks in Korea. The power cable and its accessories were subjected to type approval test in accordance with IEC 60141-1 and TNB tender documents. This paper describes the main features of the type approval tests of the cable and its accessories.

  • PDF

Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission (자동변속기 마찰요소의 동특성 해석)

  • 최영종;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF