• Title/Summary/Keyword: Transmission Line Transformer

Search Result 116, Processing Time 0.035 seconds

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

Design and Performance Evaluation of Two-Layered Microwave Absorbers(Dielectric/Magnetic) for Wide Oblique Incidence Angles Used for ITS (ITS용 2층형 전파 흡수체(유전체/자성체) 설계 및 경사 입사 흡수 특성 해석)

  • Kim, Jae-Woong;Kim, Sung-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1217-1223
    • /
    • 2007
  • Advanced microwave absorbers for wide oblique incidence angles are required in many applications including wireless communication or vehicle identification in ITS(Intelligent Transport System) where 5.8 GHz DSRC(Dedicated Short Range Communication) system is applied. In this study, two-layered microwave absorber(with a laminate structure of dielectric/magnetic composites) has been designed for the achievement of low reflection coefficient over wide incidence angles at 5.8 GHz. Iron flake particles are used as the filler in the absorbing layer, and the magnetic composite sheet exhibits high magnetic loss due to ferromagnetic resonance in gigahertz frequencies. The surface layer of low dielectric constant containing small amount of carbon black is used as the impedance transformer. On the basis of transmission line theory, the reflection loss has been calculated for the two-layer structure with variation of incident angles for both TE(Transverse Electric) and TM(Transverse Magnetic) polarizations. At the optimum thickness of the composite layers, a low value of reflection loss(less than -10 dB) has been predicted for wide incidence angles up to $55^{\circ}$ which is in good agreement with the measured value determined by free-space measurement.

Dynamic Model Based Ratio Calculation of Equivalent Reactance and Resistance of the Bulk Power Systems (동적모델을 이용한 대규모 전력계통의 등가 리액턴스와 저항 비율(X/R) 계산)

  • Kook, Kyung-Soo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2739-2746
    • /
    • 2011
  • This paper proposes the method for more effectively calculating X/R which is the ratio of equivalent reactance(X) and resistance(R) of the bulk power system and analyses the characteristic of X/R values by applying the proposed method to the real bulk power systems. X/R is used to determine the rating of the relay in the bulk power systems and its value has been accepted to be big enough to ignore the equivalent resistance of the bulk power systems. However, X/R is calculated as a big number when only the upper transformer and transmission line are considered. The correct approach to calculating X/R needs to consider all the parameters including generators, transformers, lines and loads. This paper calculates X/R of the bulk power systems using dynamic models which have been used to analyse the power system stability. The effectiveness of the proposed method is verified by applying it to the test system and X/R values of the real bulk power systems are analyzed. In addition, the dependence of X/R on the closeness of its calculating locations to the generator is verified by using the marginal loss factor which has been used in the electricity market.

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.

The optical CT output signal characteristic according to temperature change (온도변화에 따른 광CT의 출력 특성)

  • Son, Hyun-Mok;Ahn, Mi-Kyoung;Heo, Soon-Young;Jeon, Jea-Il;Park, Won-Zoo;Lee, Kwang-Sik;Kim, Jung-Bae;Kim, Min-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.29-33
    • /
    • 2004
  • In this paper, we took the basic experiment in order to explore the characteristics of optical CT(optical current transformer) for measuring high current in a superhigh voltage condition using faraday effect and wrote that. We used the 1,310[nm] Laser Diode for the source of light and PIN-Photodiode for receiver. The transmission line of light was composed of the single-mode fiber of 30[m] which could maintain the state of polarization in the optical fiber. The range of current was from 400[A] to 1300[A]. In addition, the temperature ranged from $20[^{\circ}C}]\;to\;50[^{\circ}C]$. In a same experiment condition, a power magnitude increases in proportion as input current is increasing and temperature become low. The maximum ratio of error in temperature of $50[^{\circ}C]$ appears 0.15[%] and the 0.16[%], 1.24[%] and 0.07[%] is ratio of error in respectively $40[^{\circ}C],\;30[^{\circ}C],\;and\;20[^{\circ}C]$.

  • PDF

A Study on 8 × 4 Dual-Polarized Array Antenna for X-Band Using LTCC-Based ME Dipole Antenna Structure (LTCC 기반 ME Dipole 안테나 구조를 활용한 X-Band 용 8 × 4 이중편파 배열안테나에 관한 연구)

  • Jung, Jae-Woong;Seo, Deokjin;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.25-32
    • /
    • 2021
  • In this paper, the Magneto-Electric(ME) dipole array antenna with dual-polarization in the X-Band is proposed and it is implemented and measured. The proposed array antenna is composed of 32 single ME dipole antenna and a Teflon PCB. 1 × 1 ME dipole antenna is implemented dual-polarization by radiating vertical polarization and horizontal polarization from two pairs of radiators. 2-port feeding structures are realized by lamination process using LTCC. And, each port independently feeds the radiator through a Γ-shaped feeding strip with isolation between ports. The Teflon PCB used in the antenna array has a 4-layer structure, and 2-port is fed through the top and bottom layers. The λg/4 transformer is applied to the transmission line of the Teflon PCB for impedance matching of the arrayed antenna and the Teflon PCB, and the optimal parameters are obtained through simulation. The measured maximum antenna gains of port 1 was 18.2 dBi, Cross-pol was 1.0 dBi. And the measured maximum antenna gains of port 1 was 18.1 dBi, Cross-pol was 3.2 dBi.