• Title/Summary/Keyword: Transmission Interval

Search Result 251, Processing Time 0.026 seconds

An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity

  • Bahk, Young Yil;Ahn, Seong Kyu;Jeon, Heung Jin;Na, Byoung-Kuk;Lee, Sung-Keun;Shin, Ho-Joon
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.4
    • /
    • pp.281-288
    • /
    • 2022
  • Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3-100%) and a specificity of 100% (95% CI: 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.

The incidence of unexpected delays in uploading outside radiologic images in the transfer of patients with major trauma

  • Woo, Si Jun;Kim, Yong Oh;Kim, Hyung Il
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.92-98
    • /
    • 2022
  • Purpose: Critically ill patients are frequently transferred from one point of care to a hospital that can provide a higher level of care. To achieve optimal treatment within the targeted window of time necessary for time-sensitive cases like major trauma, rapid transportation and decision making are essential. Transferred patients have often undergone radiologic imaging at the referring hospital. Examining these outside images is paramount. Therefore, this study was conducted to estimate the upload time of outside images. Methods: This retrospective study was conducted from January to April 2020. Patients transferred from other hospitals with digitally recorded CDs or DVDs of radiologic or diagnostic images were included. When the patients were registered at the emergency department reception desk, the digital images were transmitted to our picture archiving and communication system using transmission software. The time of upload and the numbers of digital images were recorded. The time interval from patient registration to the time of upload was calculated. Results: The median number of images was 688 in the trauma team activation (TTA) group (688 in the TTA group, 281 in the non-TTA trauma group, and 176 in the nontrauma group, respectively; P<0.001). The median upload time was 10 minutes. The longest upload time was 169 minutes. The upload time was more than 20 minutes in 12 cases (19.4%). Conclusions: Patients with major trauma bring more images than patients with other diseases. Unexpected delays (>20 minutes) were noted in approximately 20% of cases. It is necessary to minimize this time.

Characterization of Purple-discolored, Uppermost Leaves of Soybean; QTL Mapping, HyperspectraI Imaging, and TEM Observation

  • JaeJin Lee;Jeongsun Lee;Seongha Kwon;Heejin You;Sungwoo Lee
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.187-187
    • /
    • 2022
  • Purple-discoloration of the uppermost leaves has been observed in some soybean cultivars in recent years. The purpose of this study was to characterize the novel phenotypic changes between the uppermost and middle leaves via multiple approaches. First, quantitative trait loci mapping was conducted to detect loci associated with the novel phenotype using 85 recombinant inbred lines (RILs) of the 'Daepung' × PI 96983 population. 180K SNP data, a major quantitative trait locus (QTL) was identified at around 60 cM of chromosome 6, which accounts for 56% of total phenotypic variance. The genomic interval is about ~700kb, and a list of annotated genes includes the T-gene which is known to control pubescence and seed coat color and is presumed to encode flavonoid 35-hydroxylase (F3'H). Based on Hyperspectral imaging, the reflectance at 528-554 nm wavelength band was extremely reduced in the uppermost leaves compared to the middle (green leaves), which is presumed die to the accumulation of anthocyanins. In addition, purple-discolored leaf tissues were observed and compared to normal leaves using a transmission electronic microscope (TEM). Base on observations of the cell organelles, the purple-discolored uppermost leaves had many pigments formed in the epidermal cells unlike the normal middle leaves, and the cell wall thickness was twice as thick in the discolored leaves. The thickness of the thylakoid layer in the chloroplast the number of starch grains, the size of starch all decreased in the discolored leaves, while the number of plastoglobule and mitochondria increased.

  • PDF

A Predictive Virtual Machine Placement in Decentralized Cloud using Blockchain

  • Suresh B.Rathod
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.60-66
    • /
    • 2024
  • Host's data during transmission. Data tempering results in loss of host's sensitive information, which includes number of VM, storage availability, and other information. In the distributed cloud environment, each server (computing server (CS)) configured with Local Resource Monitors (LRMs) which runs independently and performs Virtual Machine (VM) migrations to nearby servers. Approaches like predictive VM migration [21] [22] by each server considering nearby server's CPU usage, roatative decision making capacity [21] among the servers in distributed cloud environment has been proposed. This approaches usage underlying server's computing power for predicting own server's future resource utilization and nearby server's resource usage computation. It results in running VM and its running application to remain in waiting state for computing power. In order to reduce this, a decentralized decision making hybrid model for VM migration need to be proposed where servers in decentralized cloud receives, future resource usage by analytical computing system and takes decision for migrating VM to its neighbor servers. Host's in the decentralized cloud shares, their detail with peer servers after fixed interval, this results in chance to tempering messages that would be exchanged in between HC and CH. At the same time, it reduces chance of over utilization of peer servers, caused due to compromised host. This paper discusses, an roatative decisive (RD) approach for VM migration among peer computing servers (CS) in decentralized cloud environment, preserving confidentiality and integrity of the host's data. Experimental result shows that, the proposed predictive VM migration approach reduces extra VM migration caused due over utilization of identified servers and reduces number of active servers in greater extent, and ensures confidentiality and integrity of peer host's data.

Development of aerodynamic noise measurement method for high-speed trains (고속철도차량의 공력소음 측정 시험법 개발)

  • Minseung Jung;Jaehwan Kim;Hyung-Suk Jang;Jonghwan Kim;Cheolung Cheong;Kwongi Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.131-137
    • /
    • 2024
  • Aerodynamic noise generated by the surrounding flow of a train traveling at high speed affects both outdoor and indoor noise. This study's goal is to develop a test method to measure and quantitatively evaluate aerodynamic noise through pressure perturbation data on the train surface. To accurately evaluate aerodynamic noise, it is important to separate and evaluate the compressive and incompressible pressure fluctuations mixed in the acquired surface pressure fluctuation data. This is because the noise transmission characteristics of the two pressure fluctuations are different. First, the installation length and interval of the microphone were determined to acquire surface pressure fluctuation data, and wavenumber-frequency analysis was performed to separate incompressible pressure fluctuation and compressible pressure fluctuation to obtain a sound pressure level spectrum. Finally, as a result of comparing the test results measured in the train head and trail, It was confirmed that the pressure fluctuation on the train head surface was greater than that on the tail.

Pre-exposure Prophylaxis Adherence Among Men Who Have Sex With Men: A Systematic Review and Meta-analysis

  • Suchitra Hudrudchai;Charin Suwanwong;Pitchada Prasittichok;Kanu Priya Mohan;Nopphadol Janeaim
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.1
    • /
    • pp.8-17
    • /
    • 2024
  • Objectives: The effectiveness and efficiency of pre-exposure prophylaxis (PrEP) in reducing the transmission of human immunodeficiency virus (HIV) among men who have sex with men (MSM) relies on how widely it is adopted and adhered to, particularly among high-risk groups of MSM. The meta-analysis aimed to collect and analyze existing evidence on various factors related to PrEP adherence in MSM, including demographic characteristics, sexual behaviors, substance use, and psychosocial factors. Methods: The meta-analysis followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The search included articles published between January 2018 and December 2022, obtained from the PubMed, ScienceDirect, and Scopus databases. The studies that were included in the analysis reported the proportion of MSM who demonstrated adherence to PrEP and underwent quality appraisal using the Newcastle-Ottawa Scale. Results: Of the 268 studies initially identified, only 12 met the inclusion criteria and were included in the final meta-analysis. The findings indicated that education (odds ratio [OR], 1.64; 95% confidence interval [CI], 1.12 to 2.40), number of sexual partners (OR, 1.16; 95% CI, 1.02 to 1.31), engaging in sexual activities with an human immunodeficiency virus-positive partner (OR, 1.59; 95% CI, 1.16 to 2.26), substance use (OR, 0.83; 95% CI, 0.70 to 0.99), and lower levels of depression (OR, 0.55; 95% CI, 0.37 to 0.82) were associated with higher rates of PrEP adherence among MSM. Conclusions: Despite these findings, further research is necessary to investigate PrEP adherence more comprehensively. The findings of this meta-analysis can be utilized to inform interventions aimed at improving PrEP adherence among MSM and provide directions for future research in this area.

Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking (Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가)

  • Kim, Tae Won;Yoo, Soon Mi;Jeon, Soo Dong;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.73-81
    • /
    • 2018
  • Purpose : The aims of this study were to compare and assess the effectiveness of Volumetric Modulated Arc Therapy(VMAT) using jaw tracking(JT) and fixed jaw(FJ) in radiation therapy of multiple brain metastasis. Methode and material : Among the patients with Multiple Brain Metastasis treated with jaw tracking, 10 patients with more than 6 tumors and with the size of radiation field $14{\times}14cm^2$ or more were included. Each Treatment plans with jaw tracking(JT) and fixed jaw(FJ) was established with Eclipse (Ver. 13.6 Varian, USA). Gamma Index (3 mm, 3 % confidence interval - 95 %) and maximum dose difference were measured with an electronic portal imaging device(EPID). The $D_{max}$ and $D_{mean}$ of Organ At Risk(OAR) were assessed and compared, and the Conformity Index(CI) and Homogeneity Index(HI) were evaluated. Result : Evaluating jaw tracking(JT) and fixed jaw(FJ) outcomes, in all cases, Gamma Index met the permissible standard of 3 mm, 3 % confidence intervals of 95 %. The maximum dose difference value from the areas with leaf end transmission was measured at a maximum of 98.4 % and an average of 43.6 % in clockwise(CW), and 67.9 % and 41.0 % for each in Counter-Clockwise(CCW). With jaw tracking, the maximum value of $D_{max}$ for each normal organ in OAR decreased in 15.36 %~74.59 % with the average value decreasing in 2.84 %~39.80 %. The maximum value of $D_{mean}$ in OAR decreased in 27.90 %~65.23 %, with the average value decreasing in 7.70 %~41.71 %. No change has been found in Conformity Index and Homogeneity Index values. Conclusion : When Jaw tracking is used in treating patients with multiple brain metastasis with VMAT, the unnecessary exposure due to leakage and transmission of radiation in unspecified areas was reduced, without affecting the dose distribution of the planning target volume(PTV), and the availability of radiation therapy with lower doses in normal organs is expected.

  • PDF

Viral Load Dynamics After Symptomatic COVID-19 in Children With Underlying Malignancies During the Omicron Wave

  • Ye Ji Kim;Hyun Mi Kang;In Young Yoo;Jae Won Yoo;Seong Koo Kim;Jae Wook Lee;Dong Gun Lee;Nack-Gyun Chung;Yeon-Joon Park;Dae Chul Jeong;Bin Cho
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.73-83
    • /
    • 2023
  • Purpose: This study aimed to investigate the viral load dynamics in children with underlying malignancies diagnosed with symptomatic coronavirus disease 2019 (COVID-19). Methods: This was a retrospective longitudinal cohort study of patients <19 years old with underlying hemato-oncologic malignancies that were diagnosed with their first symptomatic severe acute respiratory syndrome coronavirus 2 polymerase chain reaction (PCR)-confirmed COVID-19 infection during March 1 to August 30, 2022. Review of electronic medical records and telephone surveys were undertaken to assess the clinical presentations and transmission route of the patients. Thresholds of negligible likelihood of infectious virus was defined as E gene reverse transcription (RT)-PCR cycle threshold (Ct) value ≥25. Results: During the 6-month study period, a total of 43 children with 44 episodes of COVID-19 were included. Of the 44 episodes, the median age of the patients included was 8 years old (interquartile range [IQR], 4.9-10.5), and the most common underlying disease was acute lymphoid leukemia (n=30, 68.2%), followed by patients post-hematopoietic stem cell transplantation (n=8, 18.2%). Majority of the patients had mild COVID-19 (n=32, 72.7%), and three patients (7.0%) had severe/critical COVID-19. Furthermore, 2.3% (n=1) died of COVID-19 associated acute respiratory distress syndrome. The largest percentage of the patients showed E gene RT-PCR Ct value ≥25 between 15-21 days (n=13, 39.4%), followed by 22-28 days (n=10, 30.3%). In 15.2% (n=5), E gene RT-PCR Ct value remained <25 beyond 28 days after initial positive PCR. Refractory malignancy status (β, 67.0; 95% confidence interval, 7.0-17.0; P=0.030) was significantly associated with prolonged duration of E gene RT-PCR <25. A patient with prolonged duration of E gene RT-PCR Ct value <25 was suspected to have infectivity shown by the transmission of the virus to his mother at day 86 after his initial positive test. Conclusions: Children that acquire symptomatic COVID-19 during refractory malignancy state are at a high risk for prolonged shedding warranting PCR-based transmission precautions in this cohort of patients.

Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication (인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구)

  • Ju, Young-Jun;Gimm, Youn-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.251-257
    • /
    • 2012
  • Human body communication means transmitting and receiving data through human body medium or through free space along with the human body skin. Electric field distribution around the human body between the transmitter and the receiver were calculated at five different frequencies with 5 MHz interval between 10 MHz and 30 MHz. Commercial electromagnetic simulation tool was used for the calculation of E-field distributions applying the Korean standard male model including 29 different kinds of human tissues. After calculating specific absorption rate(SAR) values on back of the hand, it was compared with International Commission on Non-Ionizing Radiation Protection(ICNIRP) human protection guideline. While conductivities(${\sigma}$) and relative permittivities(${\varepsilon}_r$) of the human tissues for each frequency were input as the analyzing parameters, electric field intensities near both hands were integrated along the integral line between the nearby electrodes for the calculation of the transmitting and receiving voltages whose ratio was defined as channel loss. The calculated channel losses were about ($75{\pm}1$) dB and showed nearly flat response all through the evaluated frequencies.

A Study of Limitation of Service Area by UWB Transmission Jamming in DMB System (DMB 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구)

  • Kim, Dong-Ok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.4 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, n system did research about effect that interference effect with neighborhood single equipment or group equipment gets in DMB service. For this, 2.6425 GHz SDMB(Satellite Digital Multimedia Broadcasting) that a special of electric wave interference is near frequency-band including interference of signal by unnecessary radiation level that is radiated in UWB system, and degree of 3.4125GHz broadcasting relay net that is In-band frequency-band and interference effect that get in service analyzed comparison ud, modulation of broadcasting relay net and interference measurement equipment used Impulse and OFDM methods. Impulse method was $BER=1{\times}10^4$ that broadcasting signal receiption is possible at 1.4m point because interference effect happens from 2m point in SDMB system, and it was $BER=1^{\times}10-4$ that OFDM method receives interference effect from 0.8m point and broadcasting signal receiption is possible at 0.5m point. Also, about gap-filler center frequency, in case of space interval more than 0.01m, there was no interference effect. Therefore, for the electric wave of W system that is small output applies to system without interference effect in DMB service, confirmed that UWB system of OFDM method is less interference effect than UWB system of impulse method.

  • PDF