• 제목/요약/키워드: Transmission Area

검색결과 1,872건 처리시간 0.031초

최적 열전달계수를 이용한 단열기준산출

  • 이진원;이종원
    • 대한설비공학회지:설비저널
    • /
    • 제8권2호
    • /
    • pp.95-100
    • /
    • 1979
  • Optlmum overall heat transmission coefficient for residential buildings is calculated as a function of building parameter, area/volume. Equivalent heat transmission coefficient and equivalence factor are introduced and optimized with respect to annual cost including fuel cost , insulation cost and equipment cost Comparison with recent standard of West Germany shows similarity of the result.

  • PDF

Soft Sedimentary Rock Slopes Design of Diversion Tunnel

  • Jee, Warren Wangryul
    • 한국암반공학회:학술대회논문집
    • /
    • 한국암반공학회 2007년도 특별심포지엄 논문집
    • /
    • pp.63-79
    • /
    • 2007
  • Several remedial works were attempted to stabilize the collapsed area of the inlet slopes of diversion tunnel, but prevention of any further movement was being only carried out at beginning stage by filling the area with aggregates and rock debris, after several cracks had been initiated and developed around the area. The extra specialty developed folding zone is consisted with highly weathered Greywacke and Black shale. The suggested solution is to improve the properties of the rock mass of failed area by choosing the optimum level of reinforcement through the increment of slope rock support design so as to control the movement of slopes during the re-excavation. The Bakun hydroelectric project includes the construction of a hydroelectric power plant with an installed capacity of 2,520MW and a power transmission system connecting to the existing transmission networks in Sarawak and Western Malaysia. The power station will consist of a 210m height Concrete Faced Rockfill Dam. During the construction of the dam and the power facilities the Balui River has to be diverted of the tunnels is 12m and the tunnel width is 16m at the portal area. This paper describes the stability analysis and design methods for the open cut rock slopes in the inlet area of the diversion tunnels. The geotechnical parameters employed in stability calculations were given as a function of four defined Rock Mass Type (RMT) which were based on RMR system from Bieniawski. The stability calculations procedure of the rock slopes are divided into two stages. In the first stage, it is calculated for the stability of each "global" slope without any rock support and shotcrete system. In the second stage, it is calculated for each "local" slope stability with berms and supported with rock bolts and shotcrete. The monitoring instrumentation was performed continuously and some of the design modification was carried out in order to increase the safety of failed area based on the unforeseen geological risks during the open cut excavation.

  • PDF

고온초전도 케이블의 대도시 계통 적용을 위한 송전용량과 전압계급의 검토 (A Study on Capacity and Voltage Class to supply HTS Power Transmission Cable to Metropolitan Area)

  • 최상봉;김대경;정성환;성기철;김학만;김태현;김종율
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.211-214
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cable in Metropolitan area. This paper presents the possible application of a HTS superconducting power cable for transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerably economical efficiency comparable to present underground cables. In this paper, review of transmission capacity and voltage class of compact HTS cable which should be applied to existing ducts was performed.

  • PDF

스위치드-티 감쇠기를 이용한 초광대역 MMIC 디지털 감쇠기 설계 (Design of Ultra Wide Band MMIC Digital Attenuator using Switched-T Attenuator)

  • 주인권;염인복
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.39-44
    • /
    • 2005
  • A broadband DC to 40 GHz 5-bit MMIC digital attenuator has been developed. The ultra broadband attenuator has been achieved by newly inserted the transmission lines in conventional Switched-T attenuator and the optimization of the transmission line parameters. Momentum was employed in design for an accurate performance prediction at high frequencies and Monte Carlo analysis was applied to verify performance stability against the MMIC process variation. The attenuator has been fabricated with 0.15 $\mu$m GaAs pHEMT process. This attenuator has 1 dB resolution and 23 dB dynamic range. High attenuation accuracy has been achieved over all attenuation range and full 40 GHz bandwidth with the reference state insertion loss of less than 6 dB at 20 GHz. The input and output return losses of the attenuator are better than 14 dB over all attenuation states and frequencies.

  • PDF

Design of Real-Time CAN Framework Based on Plug and Play Functionality

  • Kim, Sungheo;Hwang, Kwang-il
    • Journal of Information Processing Systems
    • /
    • 제13권2호
    • /
    • pp.348-359
    • /
    • 2017
  • Nowadays most vehicles are equipped with a variety of electronic devices to improve user convenience as well as its performance itself. In order to efficiently interconnect these devices with each other, Controller Area Network (CAN) is commonly used. However, the CAN requires reconfiguration of the entire network when a new device, which is capable of supporting both of transmission and reception of data, is added to the existing network. In addition, since CAN is based on the collision avoidance using address priority, it is difficult that a new node is assigned high priority and eventually it results in transmission delay of the entire network. Therefore, in this paper we propose a new system component, called CAN coordinator, and design a new CAN framework capable of supporting plug and play functionality. Through experiments, we also prove that the proposed framework can improve real-time ability based on plug and play functionality.

Effect of the Friction Characteristics of Sliding Contacts on Electrical Signal Transmission

  • Jang, Ho;Park, Hyung Kyu
    • KSTLE International Journal
    • /
    • 제2권1호
    • /
    • pp.22-28
    • /
    • 2001
  • A resin bonded copper-graphite brush was investigated to evaluate the characteristics electrical signal transmission through a sliding contact as a function of the relative amount of graphite and copper in the brush. Particular attention was given to the correlation between electrical signal fluctuation and tribological properties in an electrical sliding contact system. A ring-on-block type tribotester was used for this experiment and the ring was made from pure copper. Results showed that a copper-graphite brush at a particular composition range exhibited the most stable frictional behavior with a minimum voltage drop. The amount of voltage drop at the friction interface was affected by the surface roughness, transfer film formation at the friction interface, and the real area of contact. Microscopic observations and the surface analysis showed a good agreement with the results from this experiment. The results also indicated that the electrical signal flunctuation was directly associated with the oscillation of the coefficient of friction during sliding by nanoscale variation of contacts at the friction interface.

  • PDF

효율적인 원거리 데이터 전송을 위한 Zigbee 노드들의 그룹화 알고리즘 (Grouping Algorithms of Zigbee Nodes for Efficient Data Transmission to Long Range)

  • 우성제;신복덕
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.632-638
    • /
    • 2012
  • ZigBee network, based on PHY, MAC layer provides a specification for a suite of high level communication protocols using small, low-power digital radio based on an IEEE 802.15.4 standard. Meshing is a type of daisy chaining from one device to another. This technique allows the short range of an individual node to be expanded and multiplied, covering a much larger area. Each wireless technology that makes it to market serves a special purpose or function. Zigbee provides short-range connectivity in what is called a personal-area network (PAN). Within ZigBee PAN coordinator as manages an entire ZigBee network, the short range of frequency band was only selected because the technology allows typically less than 100 kbp or ZigBee troubles in retransmission processing and delaying data tranmission works to create unproductive condition of work. This research was proposed the method, based on short range frequency of zigBee nodes enable to long range of remote data transmission with specific algorithm tools.

돌극형 동기 발전기의 무효전력 공급 한계 해석 및 우선공급계통에의 적용 (Analysis of Reactive Power Capability for Salient Synchronous Generators, and its Application to Primary Restorative Systems)

  • 이흥재;박성민
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.14-17
    • /
    • 2007
  • Power system restoration following a massive blackout starts with re-energizing primary restorative transmission systems at first. The comparison of the TLCC(transmission line charging capacity) and the RPC(reactive power capability) of related black-start generator should be considered in this stage because overvoltage can be caused by self-excitation at the generator when the RPC is smaller than the TLCC. The RPC can be decided by two criteria. One is stator end core heating, and the other is steady state stability. RPC in steady state stability area has been found based on a synchronous reactance Xd. This paper presents RPC limit of salient pole machine which is different from that of non-salient pole machine in steady state stability area and shows derivation process about that.

ELF 전자계 특성 및 인체 안전기준에 관한 연구 (A Study on Characteristics and Safety Criteria for Human Body in ELF Electric and Magnetic Fields)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제8권3호
    • /
    • pp.34-43
    • /
    • 1993
  • This paper presents a study on the characteristics and safety criteria for human body in ELF (Extremely Low Frequency : 50-60Hz) electric and magnetic fields. Many researches for ELF electric and magnetic fields, which are developed in the past, are studied and analyzed In this paper. In order to estabilish the safety criteria for human body in the field, the field intensity, induced current and voltage are calculated by the electrostatic field approach which is far simpler than the electromagnetic field one based on Maxwell equation. The method is applied to the 345 KV transmission line system In operation and 765 KV system under consideration. According to the results, the maximum value of field intensity, 6.8627KV/m, is evaluated at the location which is 14m away from transmission line. As the safety criteria value by the abroad researches asserting that the human can detect the Induced current in 6KV/m and above, 5KV/m and 7KV/m are recommended at residence area and nonresidence area, respectively.

  • PDF

CAN 기반 휴머노이드 로봇에서의 데이터 프레임 최소화 (Minimizing Data Frame in CAN Controller Area Network for Humanoid Robot)

  • 권선구;허욱렬;김진걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2806-2808
    • /
    • 2005
  • The Controller Area Network (CAN) is being widely used for real-time control application and small-scale distributed computer controller systems. When the stuff bits are generated by bit-stuffing mechanism in the CAN network, it causes jitter including variations in response time and delay. In order to eliminate this jitter, stuff bit must be controlled to minimize the response time and reduce the variation of data transmission time. At first, this paper shows that conventional CAN protocol causes the transmission time delay. Secondly, this paper proposes the method to reduce the stuff bits by restriction of available identifier. Finally, data manipulation method can be reduced the number of stuff-bits in the data field. The proposed restriction method of ID and manipulating data field are pretty useful to the real-time control strategy with respect to performance. These procedures are implemented in local controllers of the ISHURO (Inha Semyung Humanoid Robot).

  • PDF