• 제목/요약/키워드: Transient-flow

검색결과 1,135건 처리시간 0.03초

정상압력 유동 하에서 전기유변유체의 동적 응답 (Dynamic Responses of Electrorheological Fluid in Steady Pressure Flow)

  • 남윤주;박명관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2879-2884
    • /
    • 2007
  • Dynamic responses of electrorheological (ER) fluids in steady pressure flow to stepwise electric field excitations are investigated experimentally. The transient periods under various applied electric fields and flow velocities were determined from the pressure behavior of the ER fluid in the flow channel with two parallel-plate electrodes. The pressure response times were exponentially decreased with the increase of the flow velocity, but increased with the increase of the applied electric field strength. In order to investigate the cluster structure formation of the ER particles, it was verified using the flow visualization technique that the transient response of ER fluids in the flow mode is assigned to the densification process in the competition of the electric field-induced particle attractive interaction forces and the hydrodynamic forces, unlike that in the shear mode determined by the aggregation process.

  • PDF

과도유동현상을 이용한 모세관점도계 개발 및 적용 (Development and Application Capillary Tube Viscometer Transient Flow Concept)

  • 서상호;조민태;김동주;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.489-492
    • /
    • 2002
  • The objective of the present study were to measure the viscosities of non-Newtonian fluids by the transient flow concept in a capillary tube and to apply to hemodynamic studies and pump performance evaluations. The developed capillary tube viscometer could be used to measure the viscosities of the non-Newtonian fluids for a wide range of the shear rate by a run of experiment in a very short time interval. The measured viscosities of water and blood fur different shear rates were good agreement with those of the well established data. The measured viscosities for muddy water varied with the shear rates.

  • PDF

과도 입력파워에 대한 보와 평판의 파워흐름해석 (Transient Power Flow Analysis of Beam and Plate)

  • 황대웅;서성훈;권현웅;홍석윤
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.624-631
    • /
    • 2007
  • PFA (power flow analysis) has been recognized as a useful method in vibration analysis of medium-to-high frequency ranges. Until now, PFA method has been developed for steady-state vibration problems. In this paper, PFA method has been expanded to transient problem. New energy governing equations are derived considering time dependent terms in beam and plate. Analytic solutions of those equations are found in simple beam and plate, and are verified by comparing with modal solutions.

탄성관을 삽입한 관로에서의 비정상류에 관한 연구 (Study on Transient Flow in Pipeline with Flexible Tube)

  • 김영준;총본관
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.825-828
    • /
    • 2005
  • Experimental and numerical study was done to confirm the effect of the flexible tube in pipeline on transient flow oscillation. Experiment was made for a pipeline with and without deformable flexible tube using a single pumping system of main stainless pipe. The wave speeds of main pipe and flexible tube were calculated from the pipe material properties, structures, and boundary conditions. Time dependent pressure fluctuations were calculated for the pipeline using the simple and the Kelvin-Voigt viscoelastic models for the deformation of main pipe and flexible tube. Pressure calculated by the Kelvin-Voigt viscoelastic model showed better agreement with measured one than pressure by the simple model. Experimental and numerical results show that the maximum pressure as well as amplitude of pressure oscillation was decreased by inserting short flexible tube in pipeline. Hence, inserted short flexible tube to pipeline was found to be effective for the suppression of strong pressure oscillation. Moreover, the wave speed in pipe was discussed based on numerical and experimental results.

  • PDF

A Numerical Analysis on the Transient Heat Transfer in a Heat Exchanger Pipe Flow

  • Chang, Keun-Sun;Kweon, Young-Chel;Jin, Seong-Ryung
    • Nuclear Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.46-56
    • /
    • 2000
  • Numerical results are presented for the 2-dimensional turbulent transient heat transfer of the shell/tube heat exchanger with a step change of the inlet temperature in the primary side. Heat transfer boundary conditions outside the pipe are given partially by the convection heat transfer conditions and partially by insulated conditions. Calculation results were obtained by solving the unsteady two-dimensional elliptic forms for the Reynolds-averaged governing equations for the mass, momentum and energy. Finite-difference method was used to obtain discretization equations, and the SIMPLER solution algorithm was employed for the calculation procedure. Turbulent model used is the algebraic model proposed by Cebeci-Smith. Results presented include the time variant Nusselt number distribution, average temperature distribution and outlet temperatures for the various inlet temperatures and flow rates.

  • PDF

Nonlinear finite element analysis of reinforced concrete structures subjected to transient thermal loads

  • Zhou, C.E.;Vecchio, F.J.
    • Computers and Concrete
    • /
    • 제2권6호
    • /
    • pp.455-479
    • /
    • 2005
  • This paper describes a 2D nonlinear finite element analysis (NLFEA) platform that combines heat flow analysis with realistic analysis of cracked reinforced concrete structures. The behavior models included in the structural analysis are mainly based on the Modified Compression Field Theory and the Distributed Stress Field Model. The heat flow analysis takes into account time-varying thermal loads and temperature-dependent material properties. The capability of 2D nonlinear transient thermal analysis is then implemented into a nonlinear finite element analysis program VecTor2(C) for 2D reinforced concrete membranes. Analyses of four numerical examples are performed using VecTor2, and results obtained indicate that the suggested nonlinear finite element analysis procedure is capable of modeling the complete response of a concrete structure to thermal and mechanical loads.

The Ascendancy of Grain Configuration on the Starting Transient of Solid Rockets

  • V.R. Sanal Kumar;Kim, Heuy-Dong;B.N. Raghunandan;Toshiaki Setoguchl
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.550-559
    • /
    • 2004
  • Theoretical studies have been carried out to examine the influence of the grain geometry-dependent driving forces, which control the internal flow pattern of solid rockets. Numerical studies have been executed with the help of a two-dimensional code. This code solves standard k-omega turbulence equations using the coupled second order implicit unsteady formulation. It has been concluded that the grain port divergence angles have significant leverage on the formation of recirculation bubbles leading for pressure oscillations, flow separation and reattachment. In solid rockets flow reattachment will favour secondary ignition and that will add to the complexity of the starting transient prediction.

  • PDF

An Experimental Measurement on Transient Thermal Response in a PI-Controlled VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Kim, Won-Nyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.10-16
    • /
    • 2003
  • The present study performs an experimental measurement on transient thermal response of an air-conditioned space by a variable air volume (VAV) system with a PI(pro-portional-integral) control logic. A thermal chamber with a PI controlled VAV unit is constructed to verify the previously suggested stratified multi-zone model. The effects of thermal parameters and control parameters such as supply air temperature and PI control factor are investigated by implementing the thermal chamber test. The experimental results obtained show that transient behavior of the air-conditioned space-temperature is in good accordance with the simulation results of the stratified thermal model.

Hele-Shaw Cell 내부의 열유동 해석을 위한 홀로그래픽 간섭계와 2차원 PIV의 적용 (Application of Holographic Interferometry and 2-D PIV for HSC Convective Flow Diagnostics)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.682-687
    • /
    • 2003
  • The variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasisteady changes of temperature field, two different measurement methods of holographic interferometry; double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves can be eliminated effectively using digital image processing technique and the reconstruction images are clear, but transient flow structure cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

  • PDF

홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Convection Cell 내부 열유동 해석 (Measurement of Thermal Flow in a Hele-Shaw Convection Cell Using Holographic Interferometry and PIV Technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2002
  • Variations of temperature and velocity fields in a Hele-Shaw Convection Cell (HSC) were measured using a holographic interferometry and PIV technique with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. PIV results show that flow inside the HSC is periodic and the oscillating state is well matched with the temperature field results. The holographic interferometry and PIV techniques employed in this study are useful for analyzing the unsteady convective thermal fluid flows.

  • PDF