• 제목/요약/키워드: Transient test

검색결과 947건 처리시간 0.028초

주파수 대역별 수중 순간소음 음원준위 산출 기법 (A Calculation Method of Source Level of Underwater Transient Noise by Frequency Band)

  • 최재용;오준석;이필호
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.528-533
    • /
    • 2010
  • This paper describes a calculation method of source level of a ship transient noise, which is one of the important elements for the ship detection. Aim of transient noise measurements is to evaluate of acoustic energy due to singular occurrence, which is therefore defined as non-periodic and short termed events like an attack periscope, a rudder and a torpedo door. In generally, in the case of randomly spaced impulse, the spectrum becomes a broadband random noise with no distinctive pattern. Therefore, frequency analysis is not particularly revealing for type of signal. In the paper, it is performed in time domain to analyze a transient noise. However, a source level of transient noise is required an investigation for multiple frequency band. So, in order to calculate a source level of transient noise, a design of exponential weighting function, convolution, band pass filtering, peak detection, root mean square, and parameter compensation are applied. The effectiveness of this calculation scheme is studied through computer simulations and a sea test. Furthermore, an application of the method is applied in a real case.

등가제논진동법을 이용한 노심천이현상의 모사계산 (Equivalent Pre- Xenon-Oscillation Method for Core Transient Simulation)

  • 송재승;이창규;이정찬;유춘성;김용래
    • Nuclear Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.853-858
    • /
    • 1995
  • 노심 천 이 현상의 모사계산을 위해서는 노심상태 의 초기조건을 실제노심과 일치시켜야 하는데 특히, 제논동특성이 관심의 대상이 되는 천이현상에 있어서는 직접적인 추정이 불가능한 노심내 제논분포의 초기상태가 천이현상의 해석결과에 커다란 영향을 미치게 된다 초기상태의 노심이 정확히 제논 평형상태에 있지 않는 경우 노심의 시간에 따른 변화를 잘 예측하기 위해서는 비평형 제논분포를 모사하는 초기화가 필수적이다. 본 연구에서는 천이현상 이전에 관측된 비평형 제논진동을 등가 제논진동으로 모사하여 천이현상을 보다 정확히 예측할 수 있는 제논 초기화 기법을 개발하였으며 영광 3, 4호기 시운전 시험에서 입수된 실측자료를 통하여 그 적용성을 입증 하였다.

  • PDF

MIL-S-901D 충격시험과 과도응답해석을 이용한 DDAM 특성에 관한 연구 (Study for Characteristics of DDAM using MIL-S-901D Shock Test and Transient Response Analysis)

  • 송오섭;김룡
    • 한국소음진동공학회논문집
    • /
    • 제16권11호
    • /
    • pp.1132-1139
    • /
    • 2006
  • Non-contact underwater explosions against surface ship could cause extensive equipment damage during wartime service. Thus, the need to develop methods for the design of shock resistant equipment structures and systems was strongly established. In analytical methods, DDAM(Dynamic Design and Analysis Method) and transient repsonse method are used for ship shock design. In this paper, to analyze the characteristics of DDAM, medium weight shock test, DDAM and transient response analysis for missile system equipment are performed.

화력발전소 발전기 냉각용 수소배관계 과도진동 개선 (Reduction of Transient Vibration on $H_2$ Piping System for Generator Cooling in a Power Plant)

  • 양경현;김성휘;조철환;배춘희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.588-592
    • /
    • 2002
  • There was the transient vibration on $H_2$ piping system for cooling the generator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and exciting force from the turbine rotor by measurement and simulation test. We verified it would be changed the mode shape of the piping system by several simulation test for the structural modification of the piping system. Therefore we concluded that the change of natural vibration mode depends on deeply changing effective length of pipe and reducing supports.

  • PDF

나노유체 열전도율의 온도의존성 평가를 위한 비정상열선법의 시험방법 (Validation Test for Transient Hot-wire Method to Evaluate the Temperature Dependence of Nanofluids)

  • 강경민;이신표
    • 대한기계학회논문집B
    • /
    • 제31권4호
    • /
    • pp.341-348
    • /
    • 2007
  • One of the controversial research issues on nanofluids is the temperature dependence of the thermal conductivity of nanofluids, that is, whether it will increase or decrease according to the temperature rise. To evaluate precisely the thermal conductivity behavior of nanofluids, a systematic way of validation experiments for the measuring instrument has been highly recommended. In this paper, procedure of the validation test for transient hot-wire method using the temperature dependence of the base fluids was explained comprehensively and the comparison of the temperature dependence of water-$Al_2O_3$ nanofluids is made between the present work and that of Das et al.

OF 케이블 계통에서 과도상태시 에너지 특성 검토 (A Study on Energy Characteristics in Transient States of OF Cable Systems)

  • 정채균;이종범;강지원;이동일;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

써칭코일 시험을 통한 HVDC 해저케이블 EMTP 모델링 기법 정립 (Establishment of EMTP Modeling Method Using Searching Coil Test for HVDC Submarine Cables)

  • 정채균;박흥석;양병모;강지원;이종범
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1593-1599
    • /
    • 2010
  • This paper describes the EMTP modeling method using searching coil test for HVDC submarine cables. HVDC submarine cables consist of conductor, lead sheath and amore. It is different from general cable which is composed with just conductor and aluminium sheath. Therefore, the transient characteristics are totally different between HVDC submarine cable and general cable. However, the study on HVDC cable modeling and transient are insufficient. In this paper, EMTP modeling is performed according to grounding interval and grounding resistance, then they are compared with real test results by searching coil test.

동적 파괴에 대한 가속장치의 보정 및 시험장치 설계 (Calibration of Acceleration Plant and Test Rig Design to Dynamic Fracture)

  • 조재웅;한문식
    • 한국공작기계학회논문집
    • /
    • 제17권3호
    • /
    • pp.47-52
    • /
    • 2008
  • The force transducer in the acceleration plant due to dynamic fracture is calibrated by dynamically using the stress pulses from a longitudinal bar. The bar is supported by two strings attached to the ceiling. The bar velocities before and after impact are measured and a full bridge at bar and transducer is formed by the four strain gauges. A transient recorder is used to store the stress pulse signals of force transducer and bar. For the first test series, three point bend test specimens can be chosen by means of test rig design and the inspection as sample experiment in this presented paper is sufficient for proving with the numerical simulation of the specimen model.

IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구 (The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker)

  • 류행수;김명석;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

Evaluation of temperatures and flow areas of the Phebus Test FPT0

  • Koji Nishida;Naoki Sano;Seitaro Sakurai;Michio Murase
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.886-892
    • /
    • 2024
  • The cladding temperatures and axial mass distribution computed by MAAP5 were compared with their measured values in the test bundle of the Phebus Test FPT0. The computed cladding temperatures were in good agreed with the measured values in the pre-transient phase. In the transient heat-up phase, the computed temperatures were overestimated by the Baker-Just correlation in MAAP5, but the computed temperatures could simulate the subsequently measured values. The computed mass distribution in the axial direction was in qualitative agreement with the measured one for post-test fuel damage observations. The calculated flow areas of inner and outer regions in the test bundle were compared with the photographic observations. MAAP5 computed them at the height of 0.2 m where the molten pool formed was in qualitative agreement with the photographic observations. It was found that the remaining steam flow paths might be caused by the gas-liquid two-phase flow counter-current flow limitation.