• 제목/요약/키워드: Transient state

검색결과 1,635건 처리시간 0.024초

Effect of constant loading on unsaturated soil under water infiltration conditions

  • Rasool, Ali Murtaza;Kuwano, Jiro
    • Geomechanics and Engineering
    • /
    • 제20권3호
    • /
    • pp.221-232
    • /
    • 2020
  • In many tropical regions, soil structures often fail under constant loads as a result of decreasing matric suction due to water infiltration. Most of the previous studies have been performed by infiltrating water in the soil specimen by keeping shear stress constant at 85-90% of peak shear strength in order to ensure specimen failure during water infiltration. However, not many studies are available to simulate the soil behavior when water is infiltrated at lower shear stress and how the deformations affect the soil behavior if the failure did not occur during water infiltration. This research aimed at understanding both the strength and deformation behavior of unsaturated soil during the course of water infiltration at 25%, 50% and 75% of maximum deviatoric stress and axial strain by keeping them constant. A unique stress-strain curve expresses the transient situation from unsaturated condition to failure state due to water infiltration is also drawn. The shearing-infiltration test results indicate that the water infiltration reduces matric suction and increase soil deformation. This research also indicates that unsaturated soil failure problems should not always be treated as shear strength problems but deformation should also be considered while addressing the problems related to unsaturated soils.

Well-Conditioned 관측기 설계 - A Linear Matrix Inequality Approach - (Design of the Well-Conditioned Observer - A Linear Matrix Inequality Approach -)

  • 정종철;허건수
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.503-510
    • /
    • 2004
  • In this paper, the well-conditioned observer for a stochastic system is designed so that the observer is less sensitive to the ill-conditioning factors in transient and steady-state observer performance. These factors include not only deterministic uncertainties such as unknown initial estimation error, round-off error, modeling error and sensing bias, but also stochastic uncertainties such as disturbance and sensor noise. In deterministic perspectives, a small value in the L$_{2}$ norm condition number of the observer eigenvector matrix guarantees robust estimation performance to the deterministic uncertainties. In stochastic viewpoints, the estimation variance represents the robustness to the stochastic uncertainties and its upper bound can be minimized by reducing the observer gain and increasing the decay rate. Both deterministic and stochastic issues are considered as a weighted sum with a LMI (Linear Matrix Inequality) formulation. The gain in the well-conditioned observer is optimally chosen by the optimization technique. Simulation examples are given to evaluate the estimation performance of the proposed observer.

고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구 (An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions)

  • 박철민;부준홍;김진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF

2차원 정방형 캐비티유동장의 비정상특성 (Unsteady Characteristics of a Two-Dimensional Square Cavity Flow)

  • 이영호;최장운;도덕희
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.622-632
    • /
    • 1995
  • The present numerical study is aimed to investigate time-dependent characteristics of a two-dimensional lid-driven square cavity flow of three high Reynolds numbers, $7.5{\times}10^3$, $10^4$ and $3{\times}10^4$. A conservative convection term on irregular grids was adopted by renewing the MAC type difference schemes on regular grids. Relaxation of velocity and pressure is implemented by SOLA algorithm. In case of $Re=7.5{\times}10^3$, flow behavior converges to steady state after a transient period. But for $Re=10^4$, periodic unsteady sinusoidal fluctuation of local velocity and kinetic energy is found and continuous movements of small eddies in the secondary flow regions are also discovered. Random generation of eddies and their active migrating behavior are detected for $Re=3{\times}10^4$, resulting in complete unsteady and non-linear flow characteristics. And, an organized structure similar to a Moffat vortex is also observed from the time-mean flow patterns. Furthermore, a typoon-like vortex(TLV) appears intemittently and rotates along the separation regions and boundary layers.

  • PDF

광증폭기의 이득과 이득 평탄화를 동시에 자동 제어하는 완전 광학적 방법 (Automatic Gain Flattening Control and Automatic Gain Control Using an All Optical Method in an Optical Amplifier)

  • 최보훈;이상수
    • 한국광학회지
    • /
    • 제20권5호
    • /
    • pp.261-265
    • /
    • 2009
  • 직렬 연결된 두 개의 광학적인 회전루프와 고정형 이득 평탄화 필터가 적용된 이단 증폭기 구조가 제안되고 구현되었다. 이 증폭기에 입력신호 채널수를 한 개에서 40개 사이를 역동적으로 변화시키므로 입력신호 세기가 최고 -1 dBm 까지의 변동할 때, 제안된 증폭기는 완전히 광학적인 방법으로 이득과 이득평탄 정도를 1530 nm$\sim$1560 nm 파장대역에서 일정하게 유지시켰다. 이 특성을 잡음지수의 큰 희생 없이 고 이득을 유지하는 가운데 이루어 졌다. 각 입력채널에서 이득 특성의 시간에 따른 순간적인 변화와 이 변화의 파장 의존성도 조사되었다. 결과적으로 제안된 구조의 증폭기가 전송선에 적용될 때, 통신양의 급격한 변화에 따라 광증폭기로 입력되는 광신호의 세기가 급격히 변화하더라도 광증폭기의 증폭 특성은 일정하게 유지될 것이다.

Effect of Low-Energy Electron Irradiation on DNA Damage by Cu2+ Ion

  • Noh, Hyung-Ah;Park, Yeunsoo;Cho, Hyuck
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.63-68
    • /
    • 2017
  • Background: The combined effect of the low energy electron (LEE) irradiation and $Cu^{2+}$ ion on DNA damage was investigated. Materials and Methods: Lyophilized pBR322 plasmid DNA films with various concentrations (1-15 mM) of $Cu^{2+}$ ion were independently irradiated by monochromatic LEEs with 5 eV. The types of DNA damage, single strand break (SSB) and double strand break (DSB), were separated and quantified by gel electrophoresis. Results and Discussion: Without electron irradiation, DNA damage was slightly increased with increasing Cu ion concentration via Fenton reaction. LEE-induced DNA damage, with no Cu ion, was only 6.6% via dissociative electron attachment (DEA) process. However, DNA damage was significantly increased through the combined effect of LEE-irradiation and Cu ion, except around 9 mM Cu ion. The possible pathways of DNA damage for each of these different cases were suggested. Conclusion: The combined effect of LEE-irradiation and Cu ion is likely to cause increasing dissociation after elevated transient negative ion state, resulting in the enhanced DNA damage. For the decrease of DNA damage at around 9-mM Cu ion, it is assumed to be related to the structural stabilization due to DNA inter- and intra-crosslinks via Cu ion.

Design, test and numerical simulation of a low-speed horizontal axis hydrokinetic turbine

  • Tian, Wenlong;Mao, Zhaoyong;Ding, Hao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권6호
    • /
    • pp.782-793
    • /
    • 2018
  • A small-scale horizontal axis hydrokinetic turbine is designed, manufactured and studied both experimentally and numerically in this study. The turbine is expected to work in most of China's sea areas where the ocean current velocity is low and to supply electricity for remote islands. To improve the efficiency of the turbine at low flow velocities, a magnetic coupling is used for the non-contacting transmission of the rotor torque. A prototype is manufactured and tested in a towing tank. The experimental results show that the turbine is characterized by a cut-in velocity of 0.25 m/s and a maximum power coefficient of 0.33, proving the feasibility of using magnetic couplings to reduce the resistive torque in the transmission parts. Three dimensional Computational Fluid Dynamics (CFD) simulations, which are based on the Reynolds Averaged Navier-Stokes (RANS) equations, are then performed to evaluate the performance of the rotor both at transient and steady state.

열전달 특성이 향상된 마그네슘 수소화물을 이용한 수소저장시스템의 전산모사 (Numerical Simulation of Hydrogen Storage System using Magnesium Hydride Enhanced in its Heat Transfer)

  • 김상곤;심재혁;임연호
    • 한국수소및신에너지학회논문집
    • /
    • 제26권5호
    • /
    • pp.469-476
    • /
    • 2015
  • The purpose of this work is to investigate main factors to design a solid-state hydrogen stroage system with magnesium hydride with 10 wt% graphite using numerical simulation tools. The heat transfer characteristic of this material was measured in order to perform the highly reliable simulation for this system. Based on the measured effective thermal conductivity, a transient heat and mass transfer simulation revealed that the total performance of hydrogen storage system is prone to depend on heat and mass transfer behaviors of hydrogen storage medium instead of its inherent kinetic rate for hydrogen adsorption. Furthermore, we demonstrate that the thermodynamic aspect between equlibrium presssure and temperature is one of key factor to design the hydrogen storage system with high performance using magnesium hydride.

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.

하향유식 혐기성 고정상 생물반응기에서 유기성 폐수의 HRT변화에 따른 Biogas 생성 및 VSS 농도에 관한 연구 (A Study on the Biogas Production and VSS Concentration in Organic Wastewater Treatment Using a Downflow Anaerobic Packed Bed Reactor with HRT Change)

  • 김정회;강동수;장인용
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.17-21
    • /
    • 1993
  • Characteristics of a downflow anaerobic packed bed reactor with raschig ring ceramics as a packing were measured and discussed for the basic evaluation of the process. A synthesized glucose substrate wastewater were used as a feed and process characteristics such as pH, biogas production, composition of produced gas, COD removal and VSS were measured with the hydraulic retention time (HRT) changing from 0.25 to 2 days. As a result, this type of reactor was applicable in continuous operation within the given HRT range and the transient period approaching the steady state was about 20 days. The content of methane in produced gas increase with HRT was always high above 50% enough to use as energy source. The COD removal efficiency increased gradually as HRT increased. The axial profile of VSS concentration in the reactor usually showed the maximum at the lower region and the minimum at the middle. The VSS concentration at the upper region and the exit appeared similarly. However, at 0.25 day of HRT, the VSS concentration of effluent became higher than that of the upper region. Therefore the optimum HRT of this reactor occurred about 0.5 day, at which the production of methane began to be just stabilized and loss of VSS and COD removal were resonable.

  • PDF