• Title/Summary/Keyword: Transient faults

Search Result 124, Processing Time 0.019 seconds

A deferring strategy to improve schedulability for the imprecise convergence on-line tasks (부정확한 융복합 온라인 태스크들의 스케쥴가능성을 향상시키기 위한 지연 전략)

  • Song, Gi-Hyeon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.15-20
    • /
    • 2021
  • The imprecise real-time scheduling can be used for minimizing the bad effects of timing faults by leaving less important tasks unfinished if necessary when a transient overload occured. In the imprecise scheduling, every time-critical task can be logically decomposed into two tasks : a mandatory task and an optional task. Recently, some studies in this field showed good schedulability performance and minimum total error by deferring the optional tasks. But the schedulability performance of the studies can be shown only when the execution time of each optional task was less than or equal to the execution time of its corresponding mandatory task. Therefore, in this paper, a new deferring strategy is proposed under the reverse execution time restriction to the previous studies. Nevertheless, the strategy produces comparable or superior schedulability performance to the previous studies and can minimize the total error also.

Numerical simulation of the change in groundwater level due to construction of the Giheung Tunnel (기흥터널 건설에 따른 지하수 변화 수치모델링)

  • Lee, Jeong-Hwan;Hamm, Se-Yeong;Cheong, Jae-Yeol;Jeong, Jae-Hyeong;Kim, Ki-Seok;Kim, Nam-Hoon;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.449-459
    • /
    • 2010
  • We performed numerical simulations of the excavation of an underground structure (the Giheung Tunnel) in order to evaluate the rate of groundwater flow into the structure and to estimate the groundwater level around the structure. The tunnel was constructed in Precambrian bedrock in Gyeonggi Province, South Korea. Geological and electrical resistivity data, as well as hydraulic test data, were used for the numerical modeling. The modeling took into account the strike-slip faults that cross the southern part of Giheung Tunnel, as these structures influence the discharge of groundwater into the tunnel. The transient modeling estimated a groundwater flow rate into the tunnel of $306\;m^3$/day, with a grout efficiency of 40%, yielding good agreement between the calculated change in groundwater level (6.20 m) and that observed (6.30 m) due to tunnel excavation.

Electrical properties of a resistive SFCL with shunt resistor (분로저항을 가진 저항형 초전도 한류기의 전기적 특성)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.343-347
    • /
    • 1999
  • We fabricated a resistive SFCL having a shunt resistor parallel to it in order to bifurcate the transient current at faults. The SFCL consists of a YBCO film coated with an Au layer (10 ${\omega}$ at room temperature), which is to disperse the heat generated at hot spots in the YBCO film, and the 5 ${\omega}$ shunt resistor. The minimum quench current of the SFCL was found to be 12.2 A$_{peak}$. This SFCL successfully controlled the fault current below 23 A$_{peak}$ which is otherwise to increase up to 113 A$_{peak}$. Bifurcation of the current resulted in the temperature rise of the YBCO/Au film 3 times slower than without the shunt, protecting the SFCL at high currents.

  • PDF

Detection and Estimation of a Faults on Coaxial Cable with TFDR Algorithm (Time Frequency Domain Reflectometry 기법을 이용한 Coaxial Cable에서의 결함 감지 및 추정)

  • Song, Eun-Seok;Shin, Yong-June;Choe, Tok-Son;Yook, Jong-Gwan;Park, Jin-Bae;Powers, Edward J.
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.1
    • /
    • pp.38-50
    • /
    • 2003
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry (TFDR), is proposed to detect and locate fault in wiring. Traditional reflectometry methods have been achieved in either the time domain or frequency domain only. However, time-frequency domain reflectometry utilizes time and frequency information of a transient signal to detect and locate the fault. The time-frequency domain reflectometry approach described in this paper is characterized by time-frequency reference signal design and post-processing of the reference and reflected signals to detect and locate the fault. Design of the reference signal in time-frequency domain reflectometry is based on the determination of the frequency bandwidth of the physical properties of cable under test. The detection and estimation of the fault on the time-frequency domain reflectometry relies on the time-frequency domain reflectometry is compared with commercial time domain reflectomtery (TDR) instrument. In these experiments provided in this paper, TFDR locates the fault with smaller error than TDR. Knowledge of time and frequency localized information for the reference and reflected signal gained via time-frequency analysis, allows one to detect the fault and estimate the location accurately.

  • PDF