• 제목/요약/키워드: Transient experiment

검색결과 443건 처리시간 0.03초

레이디얼 압출에서 플랜지의 성형한계 (The Forming Limit of Flange in the Radial Extrusion)

  • 고병두;장동환;최호준;임중연;황병복
    • 소성∙가공
    • /
    • 제12권3호
    • /
    • pp.228-235
    • /
    • 2003
  • In this paper, the workability of flange in the radial extrusion is analyzed in terms of the deformation pattern, the punch load and the forming limit by using simulation and experiment. A single action pressing is applied to both simulation and experiment. The analysis in this study is focused on the transient extrusion into the gap in radial direction with various gap heights and die corner radius. Based on the surface strains where surface cracking occurs, the forming patterns and strain-fracture relationships in producing radially extruded flange are obtained.

PREDICTION OF FREE SURFACE FLOW ON CONTAINMENT FLOOR USING A SHALLOW WATER EQUATION SOLVER

  • Bang, Young-Seok;Lee, Gil-Soo;Huh, Byung-Gil;Oh, Deog-Yeon;Woo, Sweng-Woong
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1045-1052
    • /
    • 2009
  • A calculation model is developed to predict the transient free surface flow on the containment floor following a loss-of-coolant accident (LOCA) of pressurized water reactors (PWR) for the use of debris transport evaluation. The model solves the two-dimensional Shallow Water Equation (SWE) using a finite volume method (FVM) with unstructured triangular meshes. The numerical scheme is based on a fully explicit predictor-corrector method to achieve a fast-running capability and numerical accuracy. The Harten-Lax-van Leer (HLL) scheme is used to reserve a shock-capturing capability in determining the convective flux term at the cell interface where the dry-to-wet changing proceeds. An experiment simulating a sudden break of a water reservoir with L-shape open channel is calculated for validation of the present model. It is shown that the present model agrees well with the experiment data, thus it can be justified for the free surface flow with accuracy. From the calculation of flow field over the simplified containment floor of APR1400, the important phenomena of free surface flow including propagations and interactions of waves generated by local water level distribution and reflection with a solid wall are found and the transient flow rates entering the Holdup Volume Tank (HVT) are obtained within a practical computational resource.

입력 피드포워드와 퍼지 PI제어기를 갖는 3상 ZSI의 과도상태 개선 (Transient State Improvement of Three-Phase ZSI with the Input Feedforward and Fuzzy PI Controller)

  • 오연준;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.359-360
    • /
    • 2012
  • This paper proposes a scheme of auto-tuning fuzzy PI controller and input voltage feed forward to control the output voltage of a three-phase Z-source inverter (ZSI). The proposed scheme adjusts the ts (Kp and Ki) in real time in order to find the most suitable Kp and Ki for PI controller and to simplify the controller design. The proposed scheme is verified the validity by experiment and co-simulation in PSIM and MATLAB/SIMULINK both load step change and input DC voltage variation in Z-source inverter, and has compared with the conventional PID control scheme. The experiment results involve of three-phase output voltage, Z-network capacitor voltage and dc-link peak voltage value. By those analysis and comparison, the availability of the proposed method in output voltage transient response quality improving has been verified. Compared with conventional PID method, the proposed method showed a more effective and robust control performance for coping with the severe disturbance conditions.

  • PDF

Assessments of RELAP5/MOD3.2 and RELAP5/CANDU in a Reactor Inlet Header Break Experiment B9401 of RD-14M

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.426-441
    • /
    • 2003
  • A reactor inlet header break experiment, B9401, performed in the RD-14M multi channel test facility was analyzed using RELAP5/MOD3.2 and RELAP5/CANDU[1]. The RELAP5 has been developed for the use in the analysis of the transient behavior of the pressurized water reactor. A recent study showed that the RELAP5 could be feasible even for the simulation of the thermal hydraulic behavior of CANDU reactors. However, some deficiencies in the prediction of fuel sheath temperature and transient behavior in athe headers were identified in the RELAP5 assessments. The RELAP5/CANDU has been developing to resolve the deficiencies in the RELAP5 and to improve the predictability of the thermal-hydraulic behaviors of the CANDU reactors. In the RELAP5/CANDU, critical heat flux model, horizontal flow regime map, heat transfer model in horizontal channel, etc. were modified or added to the RELAP5/MOD3.2. This study aims to identify the applicability of both codes, in particular, in the multi-channel simulation of the CANDU reactors. The RELAP5/MOD3.2 and the RELAP5/CANDU analyses demonstrate the code's capability to predict reasonably the major phenomena occurred during the transient. The thermal-hydraulic behaviors of both codes are almost identical, however, the RELAP5/CANDU predicts better the heater sheath temperature than the RELAP5/MOD3.2. Pressure differences between headers govern the flow characteristics through the heated sections, particularly after the ECI. In determining header pressure, there are many uncertainties arisen from the complicated effects including steady state pressure distribution. Therefore, it would be concluded that further works are required to reduce these uncertainties, and consequently predict appropriately thermal-hydraulic behaviors in the reactor coolant system during LOCA analyses.

나노유체의 열확산율 측정을 위한 비정상열선법 센서모듈 실험 (An Experimental Study of Transient Hot-wire Sensor Module for Measuring Thermal Diffusivity of Nanofluids)

  • 이신표
    • 대한기계학회논문집B
    • /
    • 제35권2호
    • /
    • pp.113-120
    • /
    • 2011
  • 본 논문은 나노유체의 열확산율을 측정하는 센서와 주변회로 그리고 데이터의 처리방법을 제시한 것이다. 기존 비정상열선법을 이용하면 이론상 유체의 열전도율과 열확산율을 동시에 측정할 수 있으나 열전도율과 비교하여 열확산율은 많은 오차가 발생한다. 본 연구에서 제시한 방법은 측정변수가 단순하고 복잡한 센서의 교정과정을 생략할 수 있는 실용적 측면의 장점이 있다. 먼저 열확산율이 잘 알려진 유체들에 대한 검증실험을 실시하였고 나노유체의 열확산율을 측정하여 기본유체와 비교하는 과정을 예시적으로 설명하였다. 본 연구는 기존 열전도율측정에 한정되어 왔던 나노유체 연구의 범위를 열확산율 또는 비열의 개념으로 확장하였다는 관점에서 중요성을 갖는다.

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;송재용;길경석;권장우
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.133-143
    • /
    • 2001
  • 본 논문은 직각파 및 뇌충격진류에 대한 봉상접지각의 과도임피던스 특성을 정상접지지항과 비교.분석하였다. 접지계는 단일$(\Psi10[mm], 1[m])$과 5[m]의 간격을 두고 서로 연접한 3연접 봉상접지극으로 구성하였으며, 과도 임피던스 특성을 분석하기 위하여 상승시간 30[ns], 펄스폭 $20[\mus]$의 직각파전류 발생장치를 설계 제작하였다. 실제 낙뢰에 의한 접지임피던스의 변화를 관찰하기 위하여, 국제규격 ANSI/IEEE, IEC에 규정되어 있는 뇌충격전류를 인가하여 이에 따른 특성변화를 측정.분석하였다. 접지계로 유입된 과도전류는 접지계의 전위를 상승시키며, 이 때의 전위상승과 유입전류의 비로써 접지임피던스를 산출하며, 뇌격전류에 대한 경제적인 보호 수준을 평가.예측하기 위하여 임피던스 파라미터를 측정결과로부터 산출하였다. 또한 연접에 따른 접지임피던스의 감소와 접지리드선이 미치는 영향도 분석하였다.

  • PDF

인버터 구동 유도전동기에서 과도전압의 측정과 분석 (Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor)

  • 길경석;류길수;박대원;조영진;천상규;최수연
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.650-654
    • /
    • 2007
  • 유도전동기는 전기차량의 주요 동력원으로 광범위하게 사용되고 있으며, 유도전동기의 속도제어에 펄스변조 방식을 이용한 인버터의 사용이 증가하고 있다. 본 논문에서는 유도전동기의 인버터 구동시 발생하는 과도전압에 대해 연구하였다. 전원 케이블의 길이에 따른 과도전압의 크기를 측정하였으며, 시간변화율과 운전주파수에 의한 영향을 분석하였다. 실험결과, 케이블의 길이가 길어짐에 따라 과도전압의 최대값이 증가하였으며 50m 케이블에서 과도전압의 크기는 최대 3.3PU까지 측정되었다. 이러한 현상은 진행파의 반사와 투과에 의해 발생하며, 유도전동기의 인버터 구동시 케이블의 길이에 따른 과도전압의 영향을 고려하여 유도전동기의 절연을 설계해야 할 것이다.

접지전류의 입사점에 따른 정보통신설비용 수평접지전극의 과도전위상승 계산 방법 (Calculation Method of Transient Potential Rises of Horizontal Ground Electrodes Depending on Injection Point of the Ground Current)

  • 안창환
    • 전자공학회논문지
    • /
    • 제51권12호
    • /
    • pp.197-203
    • /
    • 2014
  • 뇌격전류가 정보통신설비의 접지시스템에 유입되었을 때 발생하는 과도전위상승에 대한 해석은 접지시스템을 효과적으로 설계하기 위해서 요구되는 사항 중에 하나이다. 접지시스템의 성능은 보통 접지시스템의 전기적 특성을 나타내는 접지임피던스와 과도전위상승으로 평가된다. 뇌격전류의 입사점에 따른 접지임피던스를 계산하는 방법을 제안하였다. 뇌격전류가 수평접지전극의 중앙에 입사되는 경우 델타갭소스 모델을 이용하여 접지임피던스를 계산하였다. 디바이 모델(Debye Model)을 이용하여 주파수의존적인 토양 파라미터를 적용할 수 있는 프로그램을 제안하였다. 그 이유는 접지시스템의 성능을 분석하는 상용프로그램은 주파수 의존적인 토양 파라미터 특성을 적용할 수 없기 때문이다. 동일한 조건에서의 시뮬레이션 결과의 신뢰성을 확인하기 위해서 실험을 수행하였다. 마지막으로, 토양 파라미터의 주파수의존성을 반영한 접지임피던스를 이용하여 뇌격전류파형에 따른 수평접지전극의 과도전위상승을 분석하였다.

용량성 전장센서를 이용한 과도전압측정계 (Transient Voltage Measuring System Using the Capacitive Electric Field Sensor)

  • 이복희;길경석;주문노;이성헌
    • 센서학회지
    • /
    • 제5권3호
    • /
    • pp.9-16
    • /
    • 1996
  • 본 논문에서는 고전압 임펄스전압 발생장치의 조작에 의하여 발생하는 과도전압을 측정할 수 있는 용량성분 압기를 실현하였다. 전장센서를 이용한 과도전압측정계는 고속응답의 평판형 전장센서와 광대역 전압버퍼로 구성되었으며, 사용된 전압버퍼(LH0033)의 입력임피던스는 $10^{12}{\Omega}$ 정도로 대단히 높다. 단위계단 응답특성을 파악하기 위하여 새로운 교정방법을 제안하고, 설치조건에 따른 분압비 오차를 검토하였으며, 분압비 오차를 0.5% 이내로 하기 위한 최적설치조건을 제시하였다. 교정실험으로부터 과도전압측정계의 응답시간은 약 15.78 ns이었으며, 주파수대역은 6.37 Hz에서 27.3MHz이다. 따라서 본 측정계로 과도과전압은 물론 상용주파수전압도 신호의 일그러짐 없이 측정이 가능하였다.

  • PDF

토양의 이온화영역에서 소규모 접지전극의 과도접지임피던스 특성 분석 (Characteristics Analysis of Transient Impedances of Small-sized Ground Electrodes in a Ionization Region of Soil)

  • 유앙우;엄주홍;조성철;이태형;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.78-84
    • /
    • 2009
  • 본 논문은 토양의 방전 영역에서 소규모 접지전극의 과도접지임피던스의 측정결과를 제시한다. 접지전극 주변에서 이온화 특성을 사실적으르 분석하기 위해서 세 가지 형상의 접지전극을 실외에 설치하고, 고전압 임펄스 발생기를 사용하여 시험전류를 인가하였다. 정지전극에서 대지로 흐르는 전류와 응답 전압을 분석한 결과, 접지전극 주변의 이온화는 높은 대지저항률률의 토양에서 접지임피던스 감소에 기여하며 대지전위상승을 효과적으로 제한하는 것이 확인된다. 하지만 낮은 대지저항률의 토양에서는 이온화 임계전계강도가 작아서 전극 형상이 과도접지임피던스에 거의 영향을 주지 못한다. 그리고 전극형상에 따른 실험결과, 판전극보다 침부봉전극이 이온화 영역 전압범위 내에서 과도접지임피던스 저감에 보다 효과적이다.