• Title/Summary/Keyword: Transient analysis

Search Result 3,070, Processing Time 0.037 seconds

Application of the French Codes to the Pressurized Thermal Shocks Assessment

  • Chen, Mingya;Qian, Guian;Shi, Jinhua;Wang, Rongshan;Yu, Weiwei;Lu, Feng;Zhang, Guodong;Xue, Fei;Chen, Zhilin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1423-1432
    • /
    • 2016
  • The integrity of a reactor pressure vessel (RPV) related to pressurized thermal shocks (PTSs) has been extensively studied. This paper introduces an integrity assessment of an RPV subjected to a PTS transient based on the French codes. In the USA, the "screening criterion" for maximum allowable embrittlement of RPV material is developed based on the probabilistic fracture mechanics. However, in the French RCC-M and RSE-M codes, which are developed based on the deterministic fracture mechanics, there is no "screening criterion". In this paper, the methodology in the RCC-M and RSE-M codes, which are used for PTS analysis, are firstly discussed. The bases of the French codes are compared with ASME and FAVOR codes. A case study is also presented. The results show that the method in the RCC-M code that accounts for the influence of cladding on the stress intensity factor (SIF) may be nonconservative. The SIF almost doubles if the weld residual stress is considered. The approaches included in the codes differ in many aspects, which may result in significant differences in the assessment results. Therefore, homogenization of the codes in the long time operation of nuclear power plants is needed.

A Clinical Study of Patent Ductus Arteriosus (동맥관개존증의 임상적 고찰)

  • 이선희
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.672-680
    • /
    • 1988
  • Munro is generally considered the first person to have demonstrated, in 1888, in an infant cadaver, the feasibility of dissection and ligation of a persistently patent ductus arteriosus. In august, 1938, Robert Gross reported first successful division and suture of the patent ductus of 7 year old girl. Interruption of a ductus is one of the most satisfactory and curative operations in the field of surgery for congenital heart disease. Seventy-eight consecutive cases of closure of patent ductus arteriosus were operated from June 1980 to June 1988 in the department of thoracic and cardiovascular surgery in Maryknoll Hospital. Retrospective clinical analysis of the patients were 1. There were 24 males, 54 females. 2. The age range of the patients were from 7 months to 32 years with the mean age 9.8 years. 3. Chief complaints of the patients were frequent URI[70.5%], dyspnea on exertion[36.9%], palpitation[10.3%], but 15 patients[19.2%] had no subjective symptoms. 4. Continuous machinery murmur could be heard at the 2nd or 3rd intercostal space on the left sternal border in 66 patients[84.6%]. The other 12 patients made systolic murmur. 5. Radiographic findings of the Chest P-A were cardiac enlargement in 55 patients[70%], enlargement of pulmonary conus and/or increasing density of pulmonary vascularity in 68 patients[87%]. 6. Electrocardiographic findings of the patients were within normal limit in 23 patients[36%], LVH in 38 patients[48.7%], RVH in 7 patients[9%], biventricular hypertrophy in 5 patients[6%]. 7. Cardiac catheterization performed in 62 patients. Mean Qp/Qs=2.5, mean pulmonary arterial pressure=45 mmHg. 8. 73 patients were operated through left posterolateral thoracotomy: Closure of the ductus by ligation in 64 cases, division with suture in 6 cases, and division with aortopatch in 3 cases. Ligation through median sternotomy under cardiopulmonary bypass were 5 cases. 9. There was no death associated with operation, but one case was experienced with intraoperative tearing of ductus resulting in massive bleeding. The other complications were transient hoarseness in 2 patients, chylothorax in 2 patients.

  • PDF

Predicting the Mass Burning Flux of Methanol Pool Fires by Using FDS Model (FDS 모델을 이용한 메탄올 풀 화재의 질량연소플럭스 예측)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.12-18
    • /
    • 2017
  • The present study has been conducted to predict the mass burning flux of methanol pool fire using liquid vaporization model in FDS and examine the effect of thermal properties of liquid fuel such as radiative fraction and mean absorption coefficient. A series of calculation for the pool diameter of 5 cm to 200 cm were performed and the size of computational domain was determined by the scale of the pool diameter. The reference grid size was determined by the grid sensitivity analysis and the computational grids consisted of approximately 750,000 cells. For the methanol pool fire, the mass burning flux predicted by liquid vaporization model of FDS followed the trend of transient characteristics as a function of pool diameter and showed good agreement within measurement uncertainty range of previous studies. The mass burning flux increased with increasing the radiative fraction and the mean absorption coefficient greatly affected on relatively small pool diameter.

Analysis of Hyperbolic Heat Conduction in a Thin Film (박막에서 쌍곡선형 열전도 방정식에 의한 열전도 해석)

  • 정우남;이용호;조창주
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.540-545
    • /
    • 1999
  • The classical Fourier heat conduction equation is invalid at temperatures near absolute zero or at very early times in highly transient heat transfer processes. In such situations, a hyperbolic equation model for heat conduction based on the modified Fourier law is introduced because the wave nature of heat propagation becomes dominant. The Fourier model and the hyperbolic model for heat conduction are analyzed by using the Green's function technique together with the integral transform. Analytical expressions for the heat flux and temperature distributions in a finite slab subjected to a periodic surface heating at one of its surfaces are presented and the results obtained from each model are compared with each other. The thermal wave implied b the hyperbolic model is shown to travel through a medium and to reflect back toward the origin at the other insulated surface. On the other hand, the heat by the Fourier model propagates at an infinite speed instantaneously after a thermal disturbance is felt throughout the medium.

  • PDF

Numerical Simulation of Smoke Ventilation in Rescue Route and Cross Passage of Railroad Tunnel (철도터널 화재시 연결통로 및 대피로 제연을 위한 수치해석 연구)

  • Yang, Sung-Jin;Hur, Nahm-Keon;Ryou, Hong-Sun;Kim, Dong-Hyeon;Jang, Yong-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • A transient 3-D numerical simulation was performed to analyze the fire safety in a railway tunnel equipped with a mechanical ventilation system. The behavior of pollutants was studied for the emergency operation mode of ventilation system in case of fire in the center of the rescue station and near the escape route. Various schemes of escape route construction for connection angle($45^{\circ}$, $90^{\circ}$, 135^{\circ}$) and slope($10^{\circ}$) were evaluated for the ventilation efficiency in the fire near the escape route. From the results, it was shown that the mode of the ventilation fan operation which pressurizes the tunnel not under the fire and ventilates the smoke from the tunnel under the fire is most effective for the smoke control in the tunnel in case of the fire occurrence. It was also shown that the blowing of jet fan from the rescue tunnel to the main tunnel should be in the same direction as the flow direction in the main tunnel arising from the traffic and the buoyancy.

Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System (BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가)

  • Park, Sang-Mi;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.

A Performance Analysis and Evaluation of Congestion Avoidance Algorithm for ABR service over ATM Networks (ATM망에서 ABR 서비스를 위한 혼잡회피 알고리즘의 성능 분석 및 평가)

  • 하창승;조익성
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.80-91
    • /
    • 2002
  • A general goal of the AT%(Asynchronous Transfer Mode) network is to support connect across various network. On ATM networks, ABR services are provided using the remained ban after allocation CBR and VBR traffic. Realtime services such as transmitting audio or video data may be provided using CBR ado VBR which have a constrained transmission delay, but in these cases, the communications bandwidth may be wasted. In this paper a simulation has been performed to compare and evaluate the performance between the ERICA(Explicit Rate Indicate Avoidance) and EPRCA(Enhanced Proportional Rate Control Algorithm) switches which use Explicit Rate switch algorithm for ABR switch. The variation of the ACR at the source end system, the queue length, the utilization rate of the link bandwidth and the share fairness at the transient and steady states are used as the evaluation criteria for the simulation. As a result of simulation, ERICA algorithm switch was ten times long compared to ERPCA switch to achieve assigned fair share. so EPRCA switch is superior to ERICA about load response. For Fair share and stability, ERICA switch is excellent to EPRCA switch.

  • PDF

Depilatory creams increase the number of hair follicles, and dermal fibroblasts expressing interleukin-6, tumor necrosis factor-α, and tumor necrosis factor-β in mouse skin

  • Tsai, Pi-Fen;Chou, Fen-Pi;Yu, Ting-Shuan;Lee, Huei-Jane;Chiu, Chun-Tang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.6
    • /
    • pp.497-506
    • /
    • 2021
  • Besides using for hair removal, depilatory agents have been considered to be used as a penetration enhancer for transepidermal drug delivery. To examine the effect in hair follicles (HFs), two commercially available depilatory creams were tested on the dorsal skin of mice to monitor the effect deep into the skin structure. Fifteen male BALB/c mice were used in this study. Depilatory creams were applied to the dorsal skin of the same animal using shaved and untouched treatments as controls to minimize individual differences. Skin samples were collected at three days, one week and two weeks (n = 5 for each) after the treatment, and subjected for hematoxylin-eosin staining, and immunohistochemical analysis for proinflammatory cytokines. The morphological examination showed an increase in the thickness of epidermal layer of the depilatory cream-treated skin at early time points and in the subcutis at two weeks. Depilatory cream promoted entry of anagen phase and increased the number of hair follicles in the subcutis at one and two weeks. Immunohistochemistry showed elevated percentages of dermal fibroblasts expressing interleukin-6, tumor necrosis factor-α, and tumor necrosis factor-β. Shaving process increased the thickness of epidermis and dermis as depilatory creams did, but did neither induce the expression of proinflammatory cytokines in the dermal fibroblasts nor the number of HFs. The results suggested that the commercially available depilatory creams caused a transient minor inflammatory response of the skin and increased the levels of cytokines that might subsequently affect hair growth.

The influence of dynamic force balance on the estimation of dynamic uniaxial compression strength (암석시료 내 동적하중 분배특성이 동적일축압축강도에 미치는 영향성에 관한 연구)

  • Oh, Se-Wook;Min, Gyeong-Jo;Park, Se-Woong;Park, Hoon;Suk, Chul-Gi;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.37 no.1
    • /
    • pp.14-23
    • /
    • 2019
  • It has been an always issue for the blasting or the impact analysis to consider the strength characteristics of the rock materials associate with loading rate dependency. Due to the nature of transient loading, the dynamic rock test requires a careful technique to achieve the stress equilibrium state of the specimen. In this study, to investigate the relationship between the rock dynamic strength and the stress equilibrium state, a series of dynamic uniaxial compression tests for Pocheon granite were performed. As a result, the unbalanced stress state on the specimen can lead to the premature failure on the specimen and the less estimation of dynamic strength characteristic as well as the overestimation of strain rate. Consequently, a careful consideration of rock fracture process to achieve the dynamic force balance on the specimen should be required to make an reasonable evaluation of rock dynamic strength.

Left Ventricular Ejection Fraction Predicts Poststroke Cardiovascular Events and Mortality in Patients without Atrial Fibrillation and Coronary Heart Disease

  • Lee, Jeong-Yoon;Sunwoo, Jun-Sang;Kwon, Kyum-Yil;Roh, Hakjae;Ahn, Moo-Young;Lee, Min-Ho;Park, Byoung-Won;Hyon, Min Su;Lee, Kyung Bok
    • Korean Circulation Journal
    • /
    • v.48 no.12
    • /
    • pp.1148-1156
    • /
    • 2018
  • Background and Objectives: It is controversial that decreased left ventricular function could predict poststroke outcomes. The purpose of this study is to elucidate whether left ventricular ejection fraction (LVEF) can predict cardiovascular events and mortality in acute ischemic stroke (AIS) without atrial fibrillation (AF) and coronary heart disease (CHD). Methods: Transthoracic echocardiography was conducted consecutively in patients with AIS or transient ischemic attack at Soonchunhyang University Hospital between January 2008 and July 2016. The clinical data and echocardiographic LVEF of 1,465 patients were reviewed after excluding AF and CHD. Poststroke disability, major adverse cardiac events (MACE; nonfatal stroke, nonfatal myocardial infarction, and cardiovascular death) and all-cause mortality during 1 year after index stroke were prospectively captured. Cox proportional hazards regressions analysis were applied adjusting traditional risk factors and potential determinants. Results: The mean follow-up time was $259.9{\pm}148.8days$ with a total of 29 non-fatal strokes, 3 myocardial infarctions, 33 cardiovascular deaths, and 53 all-cause mortality. The cumulative incidence of MACE and all-cause mortality were significantly higher in the lowest LVEF (<55) group compared with the others (p=0.022 and 0.009). In prediction models, LVEF (per 10%) had hazards ratios of 0.54 (95% confidence interval [CI], 0.36-0.80, p=0.002) for MACE and 0.61 (95% CI, 0.39-0.97, p=0.037) for all-cause mortality. Conclusions: LVEF could be an independent predictor of cardiovascular events and mortality after AIS in the absence of AF and CHD.