• Title/Summary/Keyword: Transient analysis

Search Result 3,047, Processing Time 0.034 seconds

Transient Characteristics Analysis of Structural Systems Undergoing Impact Employing Hilbert-Huang Transformation (힐버트 황 변환을 이용한 충격을 받는 시스템의 과도특성 분석)

  • Lee, Seung-Kyu;Yoo, Hong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1442-1448
    • /
    • 2009
  • Transient characteristics of a signal can be effectively exhibited in time-frequency domain. Hilbert-Huang Transform (HHT) is one of the time-frequency domain analysis methods. HHT is known for its several advantages over other signal analysis methods. The capability of analyzing non-stationary or nonlinear characteristics of a signal is the primary advantage of HHT. Moreover, it is known that HHT can provide fine resolution in high frequency region and handle large size data efficiently. In this study, the effectiveness of Hilbert-Huang transform is illustrated by employing structural systems undergoing impact. A simple discrete system and an axially oscillating cantilever beam undertaking periodic impulsive force are chosen to show the effectiveness of HHT.

Development of Software for Dynamic Analysis of Piezoelectric Underwater Transducers (압전 수중음향 센서의 동적해석 프로그램 개발)

  • 최준화;김재환;조치영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1053-1058
    • /
    • 2003
  • Piezoelectric under water acoustic transducer is a kind of device for under water detection working as not only an actuator but also a sensor. The technique that can predict acoustical characteristics of transducer is important for robust design of transducer in harsh underwater environment. This paper represents the development of software for analyzing dynamic characteristics of piezoelectric acoustic transducers based on finite element method. Modal and transient analysis modulo for acoustic transducers are developed TWO dimensional model for Tonpilz transducer is used for the test of the developed nodal and transient analysis modules. and comparison is made with a commercial code, ANSYS.

  • PDF

A Study on the Nonlinear Dynamic Behaviors of Arches due to the Change of Shapes and Boundary conditions (형상과 단부조건에 따른 아치의 비선형 동적거동)

  • 여동훈;이상호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.441-448
    • /
    • 1998
  • In this study, an explicit transient analysis program considering material and geometric nolinearities has been developed and used to analyze the dynamic behaviors of circular, parabolic, sinusoidal and catenary arches according to the change of shapes and boundary conditions. To understand dynamic behaviors of arches, first of all, the results of free vibration analysis for four kinds of arches are discussed. The results of transient analysis under impact loads we discussed in respect of boundary condition, change of height, and arch-shape. The dynamic behaviors of arches by nonlinear transient analysis considering both material and geometric nolinearities are also discussed.

  • PDF

Seepage analysis of agricultural reservoir due to raising embankment (농업용 저수지 둑 높이기에 따른 제체의 침투류 해석)

  • Lee, Dal-Won;Lee, Kwang-Sol;Lee, Young-Hak
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.493-504
    • /
    • 2011
  • This study was carried out to safety evaluation, the practical application and improvement of design method of the agricultural reservoir due to raising embankments. Also, it was to compare and analyze the pore water pressure (PWP), seepage (leakage) quantity and piping phenomenon according to high water table and rapid drawdown. The seepage analysis by finite element analysis was used for steady state and transient condition. The pore water pressure distribution for steady state and transient condition showed positive(+) PWP on the upstream slope, it was gradually changed negative(-) PWP on the downstream slope. The PWP in the core ranged from 100 ~ -33 kPa, the seepage line in the incline-type core suddenly decreased towards the lower levels from the higher levels. The PWP according to rapid drawdown is remained in the vicinity of the upstream slope, therefore, it is investigated to be in an unstable state by the slope stability analysis. The PWP after raising embankments showed smaller than in the before raising embankments. It was likely to be the piping phenomenon because the gradients in the before raising embankments showed largely at downstream slope, and the stability for piping in the after raising embankments increased stable state. The seepage quantity per 1 day and the leakage per 100m for the steady state and transient condition appeared to be safe against the piping. It reduced slightly regardless of the transient condition before the raising embankments and it decreased largely about 2.4 times in the early days after the raising embankments.

Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis (과도액정기법을 이용한 열전달 측정 및 수치해석)

  • Hong Cheol-Hyun;Lee Ki-Baik;Yang Jang-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Effects of Initial Conditions on Transient Responses in Dynamic Simulation of FOWT (초기 조건이 부유식 풍력터빈 동역학 해석의 과도응답에 미치는 영향)

  • Song, Jin-Seop;Rim, Chae-Whan;Moon, Seok-Jun;Nam, Yong-Yun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.288-293
    • /
    • 2014
  • The IEC standard for onshore or offshore wind turbines requires additional dummy simulations (at least 5 s) for the transient responses due to initial conditions. An increase in the dummy time causes a considerable increase in the computational cost considering multiple design spirals with several thousand design load analysis cases. A time of 30 s is typically used in practical simulations for a wind turbine design with a fixed platform. However, 30 s may be insufficient for floating offshore wind turbines (FOWT) because the platforms have lower natural frequencies, and the transient responses will last much longer. In this paper, an initial condition application algorithm is implemented for WindHydro, and the appropriate dummy simulation time is investigated based on a series of dynamic simulations of a FOWT. As a result, it is found that more than 300 s is required for the platform to have stationary motion after the initial transient responses for the FOWT under the conditions considered.

A Study on the Electromagnetic Transients at Switching Capacitor Banks in a Electric Distribution Electric Power Distribution Substation (배전변전소에서 캐패시터 뱅크 투입시 일어나는 전자과도 현상에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.92-99
    • /
    • 2002
  • Transient in an electric distribution system are mainly generated by switching. This paper presents analysis of switching surge and means of limiting the voltage magnification transient for high voltage power systems by using the EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor contraction capacitor banks to harmonics filters. An inductance in series with the capacitor bank was used to decrease the transient voltage at the customer bus to acceptable levels. And also simulation results used the EDSA harmonics analysis program show the effect of harmonics reduction.

A study on response analysis of 6-DOF pneumatic vibration isolation table loaded by transient movements of carriage on it (상판 위 질량의 순간적인 움직임에 의해 가진되는 6-자유도 공압제진대의 진동 응답에 대한 연구)

  • Sun, Jong-Oh;Shin, Yun-Ho;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.97-102
    • /
    • 2007
  • As environmental vibration requirements on precision equipments get more stringent, use of pneumatic vibration isolators becomes more crucial and, hence, their dynamic performance needs to be further improved. Dynamic behavior of those pneumatic vibration isolation tables is very important to both manufacturer and customer as performance specifications. Together with conventional transmissibility, transient response characteristics are another critical performance index especially when movements of components, e.g., x-y tables, of the precision equipments are very dynamic. In this paper, analysis on transient response of a pneumatic vibration isolation table loaded by a mass moving on it is presented. This is a conventional dynamics problem on a rigid body with 6 degree of freedom and a mass with another degree of freedom. How to obtain transient responses of the isolation table is described when the movements of the mass are prescribed relative to the table.

  • PDF

RTDS-based Model Component Development of a Tri-axial HTS Power Cable and Transient Characteristic Analysis

  • Ha, Sun-Kyoung;Kim, Sung-Kyu;Kim, Jin-Geun;Park, Minwon;Yu, In-Keun;Lee, Sangjin;Kim, Jae-Ho;Sim, Kideok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2083-2088
    • /
    • 2015
  • The transient characteristics of the tri-axial High Temperature Superconducting (HTS) power cable are different from those of a conventional power cable depending on whether the cable is under a steady or transient state due to the quench. Verification using simulation tools is required to confirm both the characteristics of the cable and the effect of the cable when it is applied to a real utility. However, a component for the cable has not been provided in simulation tools; thus the RTDS-based model component of the tri-axial HTS power cable was developed, and a simulation was performed under the transient state. The considered properties of model component include resistance, reactance and temperature. Simulation results indicate the variation of HTS power cable condition. The results are used for the transient characteristic analysis and stability verification of the tri-axial HTS power cable. In the future, the RTDS-based model component of the cable will be used to implement the hardware-in-the-loop simulation with a protection device.

Cascaded Propagation and Reduction Techniques for Fault Binary Decision Diagram in Single-event Transient Analysis

  • Park, Jong Kang;Kim, Myoungha;Kim, Jong Tae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 2017
  • Single Event Transient has a critical impact on highly integrated logic circuits which are currently common in various commercial and consumer electronic devices. Reliability against the soft and intermittent faults will become a key metric to evaluate such complex system on chip designs. Our previous work analyzing soft errors was focused on parallelizing and optimizing error propagation procedures for individual transient faults on logic and sequential cells. In this paper, we present a new propagation technique where a fault binary decision diagram (BDD) continues to merge every new fault generated from the subsequent logic gate traversal. BDD-based transient fault analysis has been known to provide the most accurate results that consider both electrical and logical properties for the given design. However, it suffers from a limitation in storing and handling BDDs that can be increased in size and operations by the exponential order. On the other hand, the proposed method requires only a visit to each logic gate traversal and unnecessary BDDs can be removed or reduced. This results in an approximately 20-200 fold speed increase while the existing parallelized procedure is only 3-4 times faster than the baseline algorithm.