• Title/Summary/Keyword: Transient Wave

Search Result 320, Processing Time 0.033 seconds

A Study on Analysis of Thyristors by the Half-sine wave Voltage (Thyristor의 반파전압에 의한 특성분석에 관한 연구)

  • Park, H.C.;Won, H.J.;Han, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1327-1329
    • /
    • 2000
  • The thyristor among the power-semi-conductor elements, which has large current capacity and high voltage, is used widely nowadays. When the thyristor was being used to the long time, this element may be able to arise the system trip caused by changing the characteristic and dropping the performance. Therefore, it would be necessary to analyze the characteristic of element to maintain the stable operation of the system. In oder to analyze this characteristic, it would be need to test forward direction, reverse direction and leakage current by supplying the half-sine wave voltage. Among these testing, transient current condition is generated from the testing of leakage current. This transient current may be the main factor of the error in the precise measurement of leakage current. Therefore, this paper analyzes the relationship between supply voltage and transient current in measuring leakage current of the SCR, and then suggests the condition and cause of transient current as appearing the leakage current in the testing the leakage current.

  • PDF

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;김점식;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

Travelling wave model analysis of absorptive bistable laser diode (쌍안정 레이저 다이오드의 진행파형 모델 해석)

  • 서재원;박동욱
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.276.1-277
    • /
    • 2000
  • Absorptive bistable laser diode was analyzed by using traveling wave model in conjunction with the finite-difference method. Carrier and photon density distributions were calculated and the output characteristics were obtained. The results for both the steady-state and transient (switching) cases were compared with those of the rate equation approach.

  • PDF

Transient Spray Structures of Supersonic Liquid Jet Injected by Projectile Impact Systems (발사체 충격 방식을 사용한 초음속 액체 제트의 과도 분무 형상에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.86-93
    • /
    • 2012
  • The effects of projectile impact system on the transient spray characteristic which is supersonic liquid tip velocity were studied by experimentally. Supersonic liquid jets were generated by impact of a high speed projectile driven by a Two-stage light gas gun. A high speed camera and schlieren optical system were used to capture the spray structures of the supersonic liquid jets. In a case of nozzle assembly Type-A, expansion gases accelerate a projectile which has a mass of 6 grams from 250 m/s at the exit of the launch tube. Accelerated projectile collides with the liquid storage part, then supersonic liquid jets are injected with instantaneous spray tip velocity from 617.78 m/s to 982.54 m/s with various nozzle L/d. However, In a case of nozzle assembly Type-B which has a heavier projectile (60 grams) and lower impact velocity (182 m/s), an impact pressure was decreased. Thus the liquid jet injected at 210 m/s of the maximum velocity did not penetrate a shock wave and fast break-up was occurred. Pulsed injection of liquid column generated second shock wave and multiple shock wave.

A Study on the Fault Discrimination and Location Algorithm in Underground Transmission Systems Using Wavelet Transform and Fuzzy Inference (지중송전계통에서 Wavelet 변환과 퍼지추론을 이용한 고장종류판별 및 고장점 추정에 관한 연구)

  • Park, Jae-Hong;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.116-122
    • /
    • 2006
  • The underground transmission lines is continuously expanded in power systems. Therefore the fault of underground transmission lines are increased every year because of the complication of systems. However the studies dealing with fault location in the case of the underground transmission lines are rarely reported except for few papers using traveling wave method and calculating underground cable impedance. This paper describes the algorithm using fuzzy system and travelling wave method in the underground transmission line. Fuzzy inference is used for fault discrimination. To organize fuzzy algorithm, it is important to select target data reflecting various underground transmission line transient states. These data are made of voltage and average of RMS value on zero sequence current within one cycle after fault occurrence. Travelling wave based on wavelet transform is used for fault location. In this paper, a variety of underground transmission line transient states are simulated by EMTP/ATPDraw and Matlab. The input which is used to fault location algorithm are Detail 1(D1) coefficients of differential current. D1 coefficients are obtained by wavelet transform. As a result of applying the fuzzy inference and travelling wave based on wavelet transform, fault discrimination is correctly distinguished within 1/2 cycle after fault occurrence and fault location is comparatively correct.

Transient stochastic analysis of nonlinear response of earth and rock-fill dams to spatially varying ground motion

  • Haciefendioglu, Kemal
    • Structural Engineering and Mechanics
    • /
    • v.22 no.6
    • /
    • pp.647-664
    • /
    • 2006
  • The main purpose of this paper is to investigate the effect of transient stochastic analysis on nonlinear response of earth and rock-fill dams to spatially varying ground motion. The dam models are analyzed by a stochastic finite element method based on the equivalent linear method which considers the nonlinear variation of soil shear moduli and damping ratio as a function of shear strain. The spatial variability of ground motion is taken into account with the incoherence, wave-passage and site response effects. Stationary as well as transient stochastic response analyses are performed for the considered dam types. A time dependent frequency response function is used throughout the study for transient stochastic responses. It is observed that stationarity is a reasonable assumption for earth and rock-fill dams to typical durations of strong shaking.

Numerical Study of effects on micro-pressure wave reduction by a hood on a narrow tunnel (후드를 이용한 협소 터널 미기압파 감소 효과에 대한 수치적 연구)

  • Yun Su-Hwan;Kim Byung-Yeol;Ku Yo-Cheon;Lee Dong-ho;Kwon Hyeok-Bin;Ko Tae-hwan
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.872-877
    • /
    • 2005
  • The train entry into a tunnel generates a strong compression wave in the tunnel. The high amplitude of compression wave causes high pressure gradients that are responsible for both the aural discomfort of passengers and the impulsive acoustical wave called the miro-pressure wave. This paper provides a numerical study on effects of hood for micro'-'pressure wave reduction. An axisymmetric numerical solver, considering the cross sectional area of Korean Tilting Train eXpress, is used for a transient flow field in the tunnel. Results show that the micro-pressure wave is able to be reduced by a hood. In this results, the maximum reduction of micro--pressure wave is shown at 2L(length), 1.35D(diameter) hood around $56\%$ against the non-hood case.

  • PDF

Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor (인버터 구동 유도전동기에서 과도전압의 측정과 분석)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Park, Dae-Won;Cho, Young-Jin;Cheon, Sang-Gyu;Choi, Su-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.650-654
    • /
    • 2007
  • Induction motors are widely used as a source of driving force in electric vehicles and pulse width modulation (PWM) inverters are applied to their operation. The issue is that insulation of inverter-fed induction motors (IFMs) are more stressed than in line-powered motors by transient voltages. This paper dealt with experimental results on transient voltage produced by the PWM operation of an induction motor. The peak and the dv/dt of transient voltage depending on the length of power feeding cable and operating frequency were investigated. In the experiment, transient voltages up to 3.3PU of the rated-inverter voltage were recorded for the cable length of 50m. As the cable length is increased, the peak voltage appeared at the motor terminals increases. This phenomenon can be explained by the reflection and the transmission of travelling wave. Consequently, special care for the cable length between the motor and the inverter should be taken in the use of IFM to ensure the full life of insulation system.

Variation of Transient-response in Open-ended Microstrip Lines with Optically-controlled Microwave Pulses

  • Wang, Xue;Kim, Kwan-Woong;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.53-57
    • /
    • 2009
  • In this paper we develop a method to observe faults in semiconductor devices and transmission lines by calculating the variation of the reflection function in a dielectric microstrip line that has an open-ended termination containing an optically induced plasma region. It is analyzed with the assumption that the plasma is distributed homogeneously in laser illumination. With the non linear material of degradation, the concentration of the carrier in the part of the material has changed. Since the input wave has produced the phenomenon of reflection, the input signal to the open-ended microstrip lines can be observed on reflection to identify the location of the fault. The characteristic impedances resulting from the presence of plasma are evaluated by the transmission line model. The variation of the reflection wave in the microwave system has been calculated by using an equivalent circuit model. The transient response has been also evaluated theoretically for changing the phase of the variation in the reflection. The variation of characteristic response in differentially localized has been also evaluated analytically.

Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines (특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성)

  • Shim, Seo-Hyun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.