• Title/Summary/Keyword: Transient Pressure

Search Result 827, Processing Time 0.027 seconds

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

Effects of Intracerebroventricular TFMPP on Rabbit Renal Function (뇌실내 TFMPP가 가토신장기능에 미치는 효과)

  • Lim, Young-Chai;Choi, Johng-Bom;Kim, Kyung-Keun;Kook, Young-Johng
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.2
    • /
    • pp.137-146
    • /
    • 1992
  • The central tryptaminergic system has been shown to play an important role in the regulation of renal function: $5-HT_1$ receptor mediate diuresis and natriuresis, whereas both $5-HT_2$ and $5-HT_3$ mediate antidiuresis and antinatriuresis. Recently, $5-HT_1$ receptors are further subdivided into many subtypes, and central $5-HT_{1A}$ subtype was shown to mediate diuretic and natriuretic effects. The present study was undertaken to delineate the role of $5-HT_{1B}$ subtype. Trifluoromethylphenylpiperazine (TFMPP), a selective $5-HT_{1B}$ agonist in doses ranging from 8 to $750\;{\mu}g/kg$ icv elicited diuresis, natriuresis and kaliuresis in dose-dependent fashion, with the fractional excretion of filtered Na reaching 5.44% with $250\;{\mu}g/kg$ icv. The natriuresis outlasted the transient increases in renal hemodynamics, suggesting humoral mediation in the decreased tubular Na reabsorption. Plasma concentration of atrial natriuretic peptide increased along with the natriuresis. Systemic blood pressure transiently increased. When given intravenously, no diuresis and natriuresis was elicited, indicating the central mechanism. The icv TFMPP effects were not significantly affected by icv methysergide, a nonselective $5-HT_1$ blocker. Both ketanserin and MDL 72222, selective $5-HT_2$ and $5-HT_3$ antagonists, resp., did not abolish the TFMPP effects. Nor did NAN-190, $5-HT_{1A}$ blocker, affect the TFMPP effects. These observations suggest that central $5-HT_{1B}$ receptors may play a role in the central regulation of renal function by exerting diuretic and natriuretic influences, mainly through natriuretic factors.

  • PDF

Effect of pore-water salinity on freezing rate in application of rapid artificial ground freezing to deep subsea tunnel: concentration of laboratory freezing chamber test (고수압 해저터널에 급속 인공동결공법 적용시 간극수의 염분 농도가 동결속도에 미치는 영향 평가: 실내 동결챔버시험 위주로)

  • Oh, Mintaek;Lee, Dongseop;Son, Young-Jin;Lee, In-Mo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.401-412
    • /
    • 2016
  • It is extremely difficult to apply conventional grouting methods to subsea tunnelling construction in the high water pressure condition. In such a condition, the rapid artificial freezing method can be an alternative to grouting to form a watertight zone around freezing pipes. For a proper design of the artificial freezing method, the influence of salinity on the freezing process has to be considered. However, there are few domestic tunnel construction that adopted the artificial freezing method, and influential factors on the freezing of the soil are not clearly identified. In this paper, a series of laboratory experiments were performed to identify the physical characteristics of frozen soil. Thermal conductivity of the frozen and unfrozen soil samples was measured through the thermal sensor adopting transient hot-wire method. Moreover, a lab-scale freezing chamber was devised to simulate freezing process of silica sand with consideration of the salinity of pore-water. The temperature in the silica sand sample was measured during the freezing process to evaluate the effect of pore-water salinity on the frozen rate that is one of the key parameters in designing the artificial freezing method in subsea tunnelling. In case of unfrozen soil, the soil samples saturated with fresh water (salinity of 0%) and brine water (salinity of 3.5%) showed a similar value of thermal conductivity. However, the frozen soil sample saturated with brine water led to the thermal conductivity notably higher than that of fresh water, which corresponds to the fact that the freezing rate of brine water was greater than that of fresh water in the freezing chamber test.

Clinical Observation for the 161 Cases of CVA (뇌졸중환자(腦卒中患者) 161례(例)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Kang, Myeong-Seog;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.17-35
    • /
    • 1995
  • Clinical observation was made on 161 cases of CVA that were confirmed through brain CT, MRI scan and clinical observation. They were hospitalized in the oriental medical hospital of Kyung-Won University from January to December in 1994. 1. The CVA cases were classified into the following kinds: cerebral infarction, cerebral hemorrhage, subarachnoid hemorrhage(SAH), transient ischemic attack, hypertensive encephalopathy, and the greatest in number among them were the cases of cerebral infarction. 2. The frequency of strokes was much the same between male and female cases and most cases were over 50 of age. 3. In the case of cerebral infarction the place of the most frequent occurrences was in the MCA territory, and as for cerebral hemorrhage, in the basal ganglia area. 4. The most ordinary preceding disease was hypertension. The next was diabetes mellitus. 5. Generally it is thought that CVA occurs frequently in winter. But on the contrary this study of observation confirmed that it occurs mostly in summer. 6. The predisposing factors of cerebral infarction were usually initiated during the time of resting and sleeping and those of cerebral hemorrhage chiefly during the time of exercising. 7. As concerns the course of hospitalization, most patients passed through western medical hospitals or oriental medical hospitals. 8. For the patients the condition of whose consciousness was bad at the time of admission, the prognosis in most cases was bad. 9. The common symptoms were motor disability and verbal disturbance. 10. With regard to cerebral infarction, the average time to start physical theraphy was 11.4 days and with cerebral hemorrhage 22.7 days after stroke. 11. The duration of hospitalization was in most cases more than one month. 12. The main complication was urinary tract infection. The next was pneumonia. 13. At the time of admission to hospital, the blood pressure in most cases was high, but it well controlled at the time of discharge. 14. Most cases were given simultaneous treatment in both ways of western and oriental medicine.

  • PDF

'Clinical Observation for the 226 Cases of CVA' (뇌졸중환자(腦卒中患者) 226예(例)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Lee, Seong-Hun;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.5-24
    • /
    • 1997
  • Clinical observation was made on 226 cases of CVA that were confirmed through brain CT, MRI scan and clinical observation. They were hospitalized in the oriental medical hospital of Kyung-Won University from January to December in 1995. 1. The CVA cases were classified into the following kinds: cerebral infarction, cerebral hemorrhage, subarachnoid hemorrhage(SAH), transient ischemic attack, and the greatest in number among them were the cases of cerebral infarction. 2. The frequency of strokes was much the same between male and female cases and most cases were over 50 of age. 3. In the case of cerebral infarction the place of the most frequent occurrences was in the MCA territory, and as for cerebral hemorrhage, in the basal ganglia area. 4. The most ordinary preceding disease was hypertension. The next was diabetes mellitus. 5. Generally it is thought that CVA occurs frequently in winter. But on the contrary this study of observation confirmed that it occurs mostly in spring and summer. 6. The predisposing factors of cerebral infarction were usually initiated during the time of resting and sleeping and those of cerebral hemorrhage chiefly during the time of exercising. 7. As concerns the course of hospitalization, most patients passed through vestern medical hospitals or oriental medical hospitals. 8. For the patients the condition of whose consciousness was bad at the time of admission. the prognosis in most cases was bad. 9. The common symptoms were motor disability and verbal disturbance. 10. With regard to cerebral infarction, the average time to start physical theraphy was 6.4 days and with cerebral hemorrhage 9.7 days after stroke. 11. The duration of hospitalization was in most cases more than one month. 12. The main complication was urinary tract infection. 13. At the time of admission to hospital, the blood pressure in most cases was high, but it well controlled at the time of discharge. 14. Most cases were given simultaneous treatment in both ways of western and oriental medicine.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.