• Title/Summary/Keyword: Transient

Search Result 8,413, Processing Time 0.029 seconds

Transient Response Characteristics of Vehicle Seatbelt (자동차 시트벨트의 과도응답 특성에 관한 연구)

  • Kim, Chang-Hee;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.71-77
    • /
    • 2020
  • In recent years, as a consequence of the technological advancements in the automobile industry and changes in consumer demands, the reduction of noise inside vehicles rather than vehicle performance has increasingly become an important factor of interest. To date, most studies have focused on noise and vibration reduction techniques for the engine and drive system of vehicles. In this research, a comparative analysis for reducing the effect of vehicle seatbelts on the transient response is performed using the test of vehicle conditions and transient response analysis in accordance with seatbelt conditions. After the sensitivity analysis, the specifications for improvement were designed based on the transient response analysis. It was confirmed that the transient response characteristics were improved by the transient response analysis and vehicle conditions test. Through computer-aided engineering, the transient response characteristics of seatbelts were checked with less cost and time.

A Study of CMOS Device Latch-up Model with Transient Radiation (과도방사선에 의한 CMOS 소자 Latch-up 모델 연구)

  • Jeong, Sang-Hun;Lee, Nam-Ho;Lee, Min-Su;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.422-426
    • /
    • 2012
  • Transient radiation is emitted during a nuclear explosion. Transient radiation causes a fatal error in the CMOS circuit as a Upset and Latch-up. In this paper, transient radiation NMOS, PMOS, INVERTER SPICE model was proposed on the basisi of transient radiation effects analysis using TCAD(Technology Computer Aided Design). Photocurrent generated from the MOSFET internal PN junction was expressed to the current source and Latch-up phenomenon in the INVERTER was expressed to parasitic thyristor for the transient radiation SPICE model. For example, the proposed transient radiation SPICE model was applied to CMOS NAND circuit. SPICE simulated characteristics were similar to the TCAD simulation results. Simulation time was reduced to 120 times compared to TCAD simulation.

Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents (임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석)

  • Joe, Jeong-Hyeon;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.

Transient Characteristics of Mg/Air Fuel Cell (마그네슘/공기연료전지의 과도특성에 관한 연구)

  • Kim, Yong-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.210-215
    • /
    • 2016
  • The transient characteristics of the Mg/Air fuel cell were ascribed to the load current, electrolyte concentrations, air electrode area and electrode distance. It was found that transient phenomena occurred in the load current, which is due to activate of the oxidation and reduction reaction process. The transient time increase with the load current increase. The transient characteristics were investigated with regard to internal resistance. The maximum power output analysis was employed in order to explain the delayed action under various experimental conditions. The internal resistances had a significant effect on the transient characteristics. The transient curves thus obtained were in almost agreement with internal resistance characteristics.

Numerical prediction of transient hydraulic loads acting on PWR steam generator tubes and supports during blowdown following a feedwater line break

  • Jo, Jong Chull;Jeong, Jae Jun;Yun, Byong Jo;Kim, Jongkap
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.322-336
    • /
    • 2021
  • This paper presents a numerical prediction of the transient hydraulic loads acting on the tubes and external supports of a pressurized water reactor (PWR) steam generator (SG) during blowdown following a sudden feedwater line break (FWLB). A simplified SG model was used to easily demonstrate the prediction. The blowdown discharge flow was treated as a flashing flow to realistically simulate the transient flow fields inside the SG and the connected broken feedwater pipe. The effects of the SG initial pressure or the broken feedwater pipe length on the intensities or magnitudes of transient hydraulic loads were investigated. Then predictions of the decompression pressure wave-induced impulsive pressure differential loads on SG tubes and the transient blowdown loads on SG external supports were demonstrated and the general aspects of transient responses of such transient hydraulic loads to the FWLB were discussed.

A Study on Optimal Sequential Reclosing to Improve Transient Stability in Transmission System (송전계통 과도 안정도 향상을 위한 최적 순차 재폐로에 관한 연구)

  • Gwon, Gi-Hyeon;Oh, Yun-Sik;Park, Ji-Kyung;Jo, Kyu-Jung;Sohn, Seung-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1354-1360
    • /
    • 2013
  • In transmission system, reclosing scheme is very useful method to improve continuity of power supply and reliability of system. Especially, high speed reclosing which is used generally in transmission systems has a benefit improving transient stability. However, the reclosing can jeopardize the stability under the condition having high difference of voltage phase angle between both ends. Thus, this paper proposes optimal sequential reclosing scheme to improve transient stability due to reclosing operation. The optimal sequential reclosing is that each phase is closed sequentially considering transient energy. In this paper, 345kV and 154kV transmission system is modeled using EMTP (ElectroMagnetic Transient Program) to verify the performance and effectiveness of optimal sequential reclosing on transient stability. Also, Integral Square Error(ISE) method is used to assess the transient stability.

Characteristics of Transient Grounding Impedance under Surge Currents (서지전류에 대한 과도접지임피던스의 특성)

  • Lee, Deok-Hui;Park, Jong-Sun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.717-723
    • /
    • 1999
  • The transient characteristics of grounding systems play a major role in the protection of power equipments, electronic circuits and info-communication facilities against surges which arise from lightning or ground faults. Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about bad operation performances, a lot of economical losses, and etc. Therefore, in order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances in essential. One of this work is to examine the transient behaviors of grounding impedances under steplike currents for various grounding systems. And the other of this work is to evaluate the transient behaviors of a grid with rods under impulse currents and to investigate the effect of grounding lead wire. Transient grounding impedances of a grid with rods under impulse current waves have been measured as a parameter of the length of the grounding leads. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed. It was found that the grounding impedance gives the inductive, resistive and capacitive aspects under steplike current. Transient grounding impedance characteristics were very different with shapes, geometries of ground electrodes. Also, they were dependent on the waveform and magnitude of impulse current.

  • PDF

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

A study on the transient electron transport in GaAs bulk (GaAs 벌크에서 전자의 과도 전송 특성)

  • 임행삼;황의성;심재훈;이정일;홍순석
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.268-273
    • /
    • 1997
  • In this paper the transient electron transport in GaAs bulk is simulated by using ensemble Monte Carlo method. To analyze the transient electron transport the 10000 electrons in the .GAMMA. valley are simulated simultaneously for 10 picoseconds. The electric field-velocity relation is obtained. The high impurity density reduces the negative differential resistance effect. The result of transient average velocity shows the electron velocity in the transient state is faster than that in the steady state. This transient velocity overshoot is caused by the intervalley scattering mechanism. And we confirmed the fact that the energy relaxation time is longer than the momentum relaxation time.

  • PDF