• 제목/요약/키워드: Transformer Oil-paper

검색결과 235건 처리시간 0.02초

변압기 내부 방전에 의한 초음파 감지용 광섬유 센서 특성과 측정데이터의 wavelet 분석 (Characteristics of fiber-optic sensor to detect ultrasonic by discharge in transformer and signal analysis with wavelet transform)

  • 이상훈;지승욱;김충년;이광식;이춘하;김금영;도대호;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1882-1884
    • /
    • 2003
  • This paper introduced the characteristics of fiber-optic Mach-Zehnder interferometer to detect ultrasonic waves by discharges in oil. Noise-reduction method with wavelet and frequency-domain analysis was performed.

  • PDF

변압기 고장 진단을 위한 하이브리드형 전문가 시스템 (A Hybrid Type Based Expert System for Fault Diagnosis in Transformers)

  • 전영재;윤용한;김재철;최도혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.143-145
    • /
    • 1996
  • This paper presents the hybrid type based expert system for fault diagnosis in transformers. The proposed system uses the novel fault diagnostic technique based on dissolved gas analysis(DGA) in oil-immersed transformers. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set. Also, the uncertainty of the fault diagnostic rules are handled by using fuzzy measures. Finally, kohnen's feature map performs fault classification in transformers. To verify the effectiveness of the proposed diagnosis technique, the hybrid type based expert system for fault diagnosis has been tested by using KEPCO's transformer gas records.

  • PDF

765kV 신가평, 신태백 변전소 예방진단시스템 (Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations)

  • 권동진;심응보;정길조;김범진;김종화;유연표;은종영;신한철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF

다중 가스센서를 이용한 수소가스 측정 및 선택도 향상 연구 (Improvement of Measurement and Selectivity of Hydrogen Gas Using Multi-gas Sensors)

  • 선종호;한상보;이상화;김광화;강동식;황돈하
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.114-119
    • /
    • 2006
  • 본 논문에서는 세 가지 종류의 가스센서를 사용하여 수소가스에 대한 정량화 및 선택도를 향상시키기 위한 연구를 수행하였다. 여러 가지 수소가스 농도에 대한 각 가스센서들의 출력을 측정하였고 높은 출력과 분해능특성을 보이는 농도범위를 분석한 결과 세 가지 종류의 센서의 사용은 10,000[ppm]까지의 광대역의 수소가스농도를 신뢰성 있게 측정할 수 있는 가능성을 보여주었다. 또한 어떠한 농도의 메탄($CH_4$) 및 일산화탄소에 대한 출력과 수소에 대한 출력을 비교한 결과 세 가지 센서의 출력을 조합하면 수소가스의 선택성을 향상시킬 수 있는 것으로 나타났다.

AE(Acoustic Emission) 센서를 이용한 오차에 강인한 부분방전 위치추정 알고리즘에 관한 연구 (A Study on Algorithm Robust to Error for Estimating partial Discharge Location using Acoustic Emission Sensors)

  • 조성민;신희상;김재철;이양진;김광화
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.69-75
    • /
    • 2008
  • 본 논문에서는 오차에 강인하게 초음파센서를 이용한 부분방전 위치를 추정하는 알고리즘을 제시하였다. 변압기 내부는 유온이 균일하지 않기 때문에 초음파의 절연유에서 전달 속도를 정확하게 산정하기 힘들다. 그렇기 때문에 처리 과정에서 일정 오차가 발생하게 된다. 따라서 점검자에게 유용한 정보를 제공하기 위해 부분방전의 위치추정 알고리즘은 이런 오차를 충분히 반영하여야 한다. 기존의 위치추정 기법은 좌표로 부분방전 발생 위치를 나타내었지만 본 논문에서 제시하는 Lookup-Table(LUT)를 이용한 기법은 부분방전 발생 위치를 지도형태로 나타내도록하여 점검자에게 충분히 유용한 정보를 제공할 수 있도록 하였다. 또한 임의로 데이터에 오차를 일으켜 기존 기법과 제시한 기법의 성능을 비교하였다.